DOWNLOAD Sony XTL-6100 Service Manual ↓ Size: 419.34 KB | Pages: 15 in PDF or view online for FREE

Model
XTL-6100
Pages
15
Size
419.34 KB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
xtl-6100.pdf
Date

Sony XTL-6100 Service Manual ▷ View online

– 5 –
– 6 –
– 7 –
SECTION 2
ELECTRICAL ADJUSTMENTS
Equipment
Use the following test equipment for alignment.
• Oscilloscope dual trace, 10 MHz band or above with delay mode
(use a 10 to 1 probe unless otherwise instructed.)
• PAL color bar generator
• DC power supply
• Digital voltmeter
• XT-981V (Hideaway unit)
• Frequency counter
Equipment Connections
Make the test equipment connections as shown below (unless
instructed otherwise) and perform the alignment.
INPUT 1
VIDEO
color bar
generator
XT-981V
XVM-612
VIDEO output
(75 
)
MONITOR OUT
 MONITOR SECTION
Voltage Adjustment
Setting :
DIMMER selector (S701) : HIGH
BRIGHT dial (RV702)
: Max. (light)
VOL dial (RV301)
: Max.
Procedure :
1. Input the color bar (chroma off) signal from PAL color bar gen-
erator and display on the monitor screen.
2. Connect the digital voltmeter to CL66 on the monitor main
board.
3. Adjust RV401 (+5V) so that the digital voltmeter reads 5 
±
 0.1 V
DC.
4. Connect the digital voltmeter to CL86 on the monitor main
board.
5. Adjust RV601 (+9V) so that the digital voltmeter reads 8.5 
±
 0.1 V
DC.
Connection points : Monitor main board
Alignment points : Monitor main board
RGB Adjustment
Procedure :
1. Input the color bar (chroma off) signal from PAL color bar gen-
erator and display on the monitor screen.
2. Connect the digital voltmeter to CL151 on the monitor main
board.
3. Adjust RV213 (OFFSET) so that the digital voltmeter reads 2.3
±
 0.1 V DC.
4. Connect the oscilloscope to CL42 on the monitor main board.
5. Adjust RV212 (COM CUT) so that the lower black level is 6.2
±
 0.05 V DC.
6. Adjust RV208 (COM DRIVE) so that the upper 100% white
level is 9.2 
±
 0.05 V DC.
7. Repeat steps 5 & 6 until the items in the standards are satisfied.
8. Connect the oscilloscope to CL41 of the monitor main board.
9. Adjust RV207 (R DRIVE) so that the lower black level is 6.2 
±
0.05 V DC.
10. Adjust RV202 (R CUT) so that the upper 100% white level is
9.2 
±
 0.05 V DC.
11. Repeat steps 9 & 10 until the items in the standards are satisfied.
12. Connect the oscilloscope to CL43 of the monitor main board.
13. Adjust RV209 (B DRIVE) so that the upper 100% white level
is 6.1 
±
 0.05 V DC.
14. Adjust RV204 (B CUT) so that the upper 100% white level is
9.1 
±
 0.05 V DC.
15. Repeat steps 13 & 14 until the items in the standards are satisfied.
1
2
3
4
5
6
7
8
white level (1st step)
black level (8th step)
0 V
Connection points : Monitor main board
Alignment points : Monitor main board
– 8 –
V COM Adjustment
Procedure :
1. Connect the oscilloscope to CL44 on the monitor main board.
2. Adjust RV210 (V COM AMP) & RV211 (V COM BIAS) so
that the output waveform is within the standards.
3. Repeat step 2 until the standards are satisfied.
Standard values :
A : Adjust RV210 so the value is 4.9 
±
 0.1 Vp-p.
B : Adjust RV211 so the value is 5.1 
±
 0.1 V.
A
B
0 V
Connection points : Monitor main board
RV207
R DRIVE
ADJ
RV208 
COM DRIVE
ADJ
RV213
OFFSET
ADJ
RV212
COM CUT
ADJ
RV202
R CUT
ADJ
RV209
B DRIVE ADJ
RV204
B CUT ADJ
RV210
V COM AMP ADJ
RV211
V COM BIAS ADJ
RV401
+5V ADJ
RV601
+9V ADJ
– MONITOR MAIN BOARD (COMPONENT SIDE) 
– MONITOR MAIN BOARD  (CONDUCTOR SIDE) 
CL44
CL43
CL41
CL66
CL42
CL151
Alignment points : Monitor main board
Page of 15
Display