Sony XR-CA310 / XR-L210 Service Manual ▷ View online
XR-CA310/L210
13
2-9.
MAIN BELT, SUB BELT (C)
1
main belt
4
sub belt (c)
2
screw
(PTP2
(PTP2
×
3)
A
2
screw
(PTP2
(PTP2
×
3)
2
screw
(PTP2
(PTP2
×
3)
2
screw
(PTP2
(PTP2
×
3)
3
Lift up the bottom BKT (TS)
in the direction of arrow
in the direction of arrow
A
(as far as the belt can be removed).
14
XR-CA310/L210
SECTION 3
MECHANICAL ADJUSTMENTS
SECTION 4
ELECTRICAL ADJUSTMENTS
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 5.89 mN•m
(more than 60 g)
Reverse
CQ-403R
(more than 2.12 oz)
• Tape Tension Measurement
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note:
With this set, it is not necessary to apply suitable locking
compound to the parts after the azimuth adjustment.
compound to the parts after the azimuth adjustment.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN•m
Forward
CQ-102C
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Forward
0.15 – 0.39 mN•m
CQ-102C
(1.5 – 4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
2.46 – 5.39 mN•m
Reverse
CQ-102RC
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Reverse
0.15– 0.39 mN•m
CQ-102RC
(1.5 –
4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
4.91 – 14.70 mN•m
FF, REW
CQ-201B
(50 – 150 g•cm)
(0.69 – 2.08 oz•inch)
TEST MODE
This set have the test mode function. In the test mode, FM RDS S-
Meter, FM Auto Seek/Stop Level and MW Auto Seek/Stop Level
adjustments can be performed easier than it in ordinary proce-
dure.
Meter, FM Auto Seek/Stop Level and MW Auto Seek/Stop Level
adjustments can be performed easier than it in ordinary proce-
dure.
<Set the Test Mode>
1. Turn ON the regulated power supply. (All LEDs on the set
1. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
Press the
[OFF]
button, if the clock is not displayed.
2. Push the
[4]
button.
3. Push the
[5]
button.
4. Press the
[1]
button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the
1. Push the
[OFF]
button.
15
XR-CA310/L210
TAPE DECK SECTION
0 dB= 0.775 V
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
Test Tape
PB Head Azimuth Adjustment
Procedure:
1. Put the set into the FWD PB mode.
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value. Adjust the
screw so that the peak value in channels L and R coincides
within 3 dB.
within 3 dB.
3. Check the phase in the FWD PB mode.
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode
5. Check that output level difference between FWD PB mode
and REV PB mode is within 4 dB.
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 dB
tape speed adjustment
Adjustment Location: PB head
Tape Speed Adjustment
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the frequency counter becomes in 3,015 Hz.
Specified Value: 2,940 to 3,090 Hz
Adjustment Location: See page 18.
level
meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal
4
Ω
+
–
–
screw
position
position
L-CH
peak
peak
within
3 dB
3 dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
3 dB
3 dB
angle
R-CH
peak
peak
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
–
–
Screen pattern
in phase
good
wrong
45
°
90
°
135
°
180
°
4
Ω
4
Ω
set
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
set
speaker out terminal
–
+
4
Ω
FWD
REV
adjustment
screws
screws
16
XR-CA310/L210
TUNER SECTION
0 dB=1
µ
V
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
cause its internal block is difficult to repair.
Note:
Adjust the tuner section in the sequence shown below.
1. FM RDS S-Meter Adjustment
2. FM Auto Seek/Stop Level Adjustment
3. FM Stereo Separation Adjustment
4. MW Auto Seek/Stop Level Adjustment
2. FM Auto Seek/Stop Level Adjustment
3. FM Stereo Separation Adjustment
4. MW Auto Seek/Stop Level Adjustment
FM RDS S-Meter Adjustment
Setting:
[SOURCE]
(CA310) or
[TUNER]
(L210) button: FM
Procedure:
1. Set to the test mode. (see page 14)
2. Push the
1. Set to the test mode. (see page 14)
2. Push the
[SOURCE]
(CA310) or
[TUNER]
(L210) button and
set to FM.
Display
3. Push the
[6]
button.
4. Adjust RV100 on main board so that the display indication is
“8.2”.
Display
Specified Value: Display indication: 8.2
±
0.2
Adjustment Location: See page 18.
FM Auto Seek/Stop Level Adjustment
Setting:
[SOURCE]
(CA310) or
[TUNER]
(L210) button: FM
Procedure:
1. Set to the test mode. (see page 14)
2. Push the
1. Set to the test mode. (see page 14)
2. Push the
[SOURCE]
(CA310) or
[TUNER]
(L210) button and
set to FM.
Display
3. Adjust with the volume RV3 on TU100 so that the “FM” indi-
cation turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV3 so that
put out light “0” indication and adjustment.
But, in case of already indicated “FM0”, turn the RV3 so that
put out light “0” indication and adjustment.
Display
Adjustment Location: See page 18.
FM RF signal
generator
dummy
antenna
Carrier frequency : 98.00 MHz
Output level
Output level
: 22 dB (12.6
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
antenna
jack (ANT100)
jack (ANT100)
set
50
Ω
50
Ω
0.1pF
FM RF signal
generator
Carrier frequency : 98.00 MHz
Output level
Output level
: 35 dB (56.2
µ
V)
Mode
: mono
Modulation
: no modulation
0.01
µ
F
set
antenna jack (ANT100)
SHUF
MBP
REG
MBP
SHUF
REG
MBP
SHUF
REG
SHUF
MBP
REG
Click on the first or last page to see other XR-CA310 / XR-L210 service manuals if exist.