– 13 –
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
 Torque  Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
 Tape Tension  Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Forward
CQ-102C
0.5 - 4.5 g•cm
Back Tension
(0.01 - 0.06 oz•inch)
Reverse
CQ-102RC
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Reverse
CQ-102RC
0.5 - 4.5 g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 - 200 g•cm
(0.83 - 2.78 oz•inch)
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and MW Auto Scan/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S501) is “A (ON)” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
 Press the 
[OFF]
 button, if the clock is not displayed.
3. Push the preset 
[4]
 button.
4. Push the preset 
[5]
 button.
5. Press the preset 
[1]
 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the 
[OFF]
 button.
2. Return the “power select” switch (S501) to initially set posi-
tion.
Tape Speed Adjustment
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the speed checker or frequency counter becomes in
specification.
Specification: Constant speed
Adjustment Location: See page 16.
See the adjustment location from on page 16 for the
adjustment.
0 dB=0.775 V
TAPE  DECK  SECTION
set
+
test tape
WS-48A
(3 kHz, 0 dB)
speaker out terminal
speed checker
or
frequency counter
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075 Hz
– 14 –
TUNER  SECTION
98.00
SHUF1
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
Note:
 Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment
2. FM Noise Focus Adjustment
3. FM Stereo Separation Adjustment
4. MW Auto Scan/Stop Level Adjustment
FM Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
 button: FM
FREQUENCY SELECT switch: FM50 k
Procedure:
1. Set to the test mode. (See page 13.)
2. Push the 
[SOURCE]
 button and set to FM.
Display
3. Adjust with the volume RV2 on TU1 so that the “FM” indica-
tion turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV2 so that
put  out light “0” indication and adjustment.
Display
Adjustment Location: See page 16.
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation
0.01 
µ
F
set
antenna jack (J1)
FM
98.00
SHUF1
 0 dB=1 µV
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust RV231 (L-CH) and RV131 (R-CH) so that the level
meter reading is –6±1 dB (0.35 to 0.44 V).
Adjustment Location: See page 16.
Dolby Level Adjustment
Setting:
Preset 
[3]
 (DOLBY) button
: NR OFF
SEL (BAS) button
: Center
SEL (TRE) button
: Center
SEL (BAL) button
: Center
SEL (FAD) button
: Center
SEL (VOL) button
: Maximum
D-BASS control
: OFF
set
+
test tape
P-4-D400
(400Hz, 0dB)
MAIN board
level meter
MAIN board
TP (DOLBY )
TP (GND)
L-CH: IC301 
7
R-CH: IC301
– 15 –
FM Noise Focus Adjustment
Setting:
[SOURCE]
 button : FM
FREQUENCY SELECT switch : FM 50 k
Procedure:
1. Tune the 98.0 MHz.
2. The then output level is supposing that (A) dB.
3. Adjust with the volume RV3 on TU1 so that the output level is
(A) –32 dB then signal generator input set to –20 dB.
Adjustment Location: See page 16.
FM Stereo Separation Adjustment
Setting:
[SOURCE]
 button : FM
FREQUENCY SELECT switch : FM 50 k
Procedure:
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
L-CH Stereo separation: 
A-B
R-CH Stereo separation: 
C-D
The separations of both channels should be equal.
Specification: Separation more than 30 dB
Adjustment Location: See page 16.
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 60 dB (1 mV)
Mode
: mono
Modulation
: 1 kHz, 75 kHz deviation (100%)
0.01 
µ
F
set
antenna jack (J1)
+
speaker out terminal
level meter
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main: 1 kHz, 33.75 kHz deviation (45%)
  sub: 1 kHz, 33.75 kHz deviation (45%)
  19 kHz pilot: 7.5 kHz deviation (10%)
0.01 
µ
F
set
antenna jack (J1)
+
speaker out terminal
level meter
Ω 
AM RF signal
generator
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
Output level
: 33 dB (44.7 
µ
V)
(50 
)
set
AM dummy antenna
30 
15 pF
65 pF
antenna jack (J1)
MW
999
SHUF1
999
SHUF1
MW Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
and
[MODE]
button : MW
FREQUENCY SELECT switch : MW 9 k
Procedure:
1. Set to the test mode. (See page 13.)
2. Push the
[SOURCE]
button and set to FM.
3. Push the
[MODE]
button and set to MW.
Display
4. Adjust with the volume RV1 on TU1 so that the “MW” indica-
tion turns to “MW0” indication on the display window.
But, in case of already indicated “MW0”, turn the RV1 so that
put out light “0” indication and adjustment.
Display
Adjustment Location: See page 16.
– 16 –
Adjustment Location:
Tape Speed Adjustment
RV131
(R-CH)
RV231
(L-CH)
Dolby Level
Adjustment
TU1
RV1 MW Auto Scan/Stop Level Adjustment
RV2 FM Auto Scan/Stop Level Adjustment
RV3 FM Noise Focus Adjustment
RV4 FM Stereo Separation Adjustment
TP (GND)
S501
POWER SELECT
SWITCH
B (OFF) 
 A (ON)
S502
FREQUENCY
SELECT
SWITCH
10 k (MW)
200 k (FM)
9 k (MW)
50 k (FM)
R-CH
L-CH
TP (DOLBY)
Dolby Level Adjustment
– SET BOTTOM VIEW –
– SET UPPER VIEW –