– 13 –
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
Torque Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
 Tape Tension  Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Forward
CQ-102C
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
Reverse
CQ-102RC
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Reverse
CQ-102RC
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 - 200 g•cm
(0.83 - 2.78 oz•inch)
0 dB= 0.775 V
TAPE  DECK  SECTION
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
Test Tape
PB Head Azimuth Adjustment
Procedure:
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value.  Adjust the
screw so that the peak value in channels L and R coincides
within 2 dB.
3. Check the phase in the FWD PB mode.
Type
 Signal
 Used for
P-4-A100
10 kHz, –10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 db
tape speed adjustment
level meter
test tape 
P-4-A100
(10 kHz, –10 dB)
set
speaker out terminal
+
screw
position
L-CH
peak
within
2 dB
output
level
L-CH
peak
R-CH
peak
within
2 dB
angle
R-CH
peak
test tape 
P-4-A100
(10 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
Screen pattern
in phase
good
wrong
45 
°
90 
°
135 
°
180 
°
set
– 14 –
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the speed checker or frequency counter becomes in
specification.
Specification: Constant speed
Adjustment Location: See page 17.
DOLBY Level Adjustment
Setting:
Preset
[3]
(DOLBY) button
: NR OFF
SEL (BAS) button
: Center
SEL (TRE) button
: Center
SEL (BAL) button
: Center
SEL (FAD) button
: Center
SEL (VOL) button
: Maximum
D-BASS control
: OFF
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust RV121 (L-CH) and RV221 (R-CH) so that the level
meter reading is –6 ± 0.5 dB (0.37 to 0.41 V).
Adjustment Location: See page 17.
See the adjustment location from on page 17 for the
adjustment.
Tape Speed Adjustment
Setting:
Speed checker
Frequency counter
–2 to +3%
2,940 to 3,090 Hz
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode
and REV PB mode is within 4 dB.
Adjustment Location: PB head
REV         FWD
adjustment screws
+
speed checker
or
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
speaker out terminal
set
+
level meter
MAIN board
L-CH: TP101 (DOLBY-L)
R-CH: TP201 (DOLBY-R)
 
test tape
P-4-D400
(400 Hz, 0 dB)
set
– 15 –
Procedure:
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 26 dB
Adjustment Location: See page 17.
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
TUNER  SECTION
 0 dB=1 µV
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
Note:
 Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment.
2. FM Stereo Separation Adjustment.
3. MW Auto Scan/Stop Level Adjustment.
4. FM Polar VCO Adjustment.
5. FM Polar Pilot Adjustment.
FM Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
 button: FM 1
Procedure:
1. Tune the set to 98.0 MHz.
2. Connect the digital voltmeter to TP (SD) on MAIN board.
3. Adjust RV2 on TU1 so that the reading on the digital voltme-
ter changes point from low to high.
Adjustment Location: See page 17.
FM Stereo Separation Adjustment
Setting:
[SOURCE]
 button: FM 1
+
TP (SD)
MAIN board
digital 
voltmeter
FM RF signal 
generator
dummy
antenna
Carrier frequency : 98.00MHz
Output leve
: 20 dB (10.0 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30 %)
antenna
terminal
set
50 
50 
+
FM RF signal 
generator
dummy
antenna
Carrier frequency 
Output level         
Mode                   
Modulation          
: 98.00MHz
: 70 dB (3.2 mV)
: stereo
: main : 1 kHz, 20 kHz deviation (26.7 %)
  sub : 1 kHz, 20 kHz deviation (26.7 %)
  pilot : 19 kHz, 7.5 kHz deviation (10 %)
 
antenna
terminal
set
50 
50 
level 
meter
speaker out terminal
– 16 –
MW Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
 and 
[MODE]
 button: MW
Procedure:
1. Tune the set to 999 kHz
2. Connect the digital voltmeter to TP (SD) on MAIN board.
3. Adjust RV1 on TU1 so that the reading on the digital voltme-
ter changes point from low to high.
Adjustment Location:  See page 17.
FM Polar VCO Adjustment
Setting:
[SOURCE]
 button: FM2
Procedure:
1. Tune the set to 69.5 MHz, and set the internal modulation level
of the FM RF signal generator to 10 kHz deviation (20%).
2. Connect the frequency counter to the TP401 (VCO) on MAIN
board.
3. Adjust RV402 so that the reading on the frequency counter
becomes to 31.25 ± 0.1 kHz.
Adjustment Location:  See page 17.
AM RF signal
generator
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
Output level
: 33 dB (44.7 
µ
V)
(50 
)
set
AM dummy antenna
30 
15 pF
65 pF
antenna terminal
    
TP401 (VCO)
MAIN board
frequency counter
+
set
FM RF signal
generator
antenna terminal
Carrier frequency : 69.5 MHz
Output level          : 66 dB (1.995 mV)
+
TP (SD)
MAIN board
digital 
voltmeter
FM Polar Pilot Adjustment
Setting:
[SOURCE]
 button: FM2
Procedure:
1. Connect the level meter to the TP402 (PLT) on MAIN board.
2. Set the modulation frequency of the FM RF signal generator
to 1 kHz, 40 kHz deviation (80 %)
3. Then output level is supposing that (A) dB.
4. Set the modulation frequency of the FM RF signal generator
to 31.25 kHz, 10 kHz deviation (20%)
5. Adjust L401 so that the reading on the level meter becomes to
maximum.
6. Adjust RV401 so that the reading on the level meter becomes
to (A) + 13.0 dB ± 0.5 dB.
Adjustment Location: See page 17.
set
FM RF signal
generator
antenna terminal
Carrier frequency : 69.5 MHz
Output level          : 66 dB (1.995 mV)
    
TP402 (PLT)
MAIN board
level meter
+
Page of 34