SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S701) is “ON” position.
2. Turn ON the regulated power supply. (All LEDs on the set lights
up, and the clock is displayed.)
Note:Press the “OFF” button, if the clock is not displayed.
3. Push the preset 4 button.
4. Push the preset 5 button.
5. Press the preset 1 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the “OFF” button.
2. Set the “power select” switch (S701) is “OFF” position.
See the adjustment location from on page 21 for the ad-
justment.
0 dB=0.775 V
TAPE  DECK  SECTION
Tape Speed Adjustment
Procedure:
1. Put the set into the FWD PB mode.
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075Hz
Specification: Constant speed
Adjustment Location: See page 21.
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
erase head
rubber belts
capstan
idles
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
 Torque  Measurement
Mode
Torqu Meter
Meter Reading
Forward
CQ-102C
35–65 g•cm
(0.49–0.90 oz•inch)
Forward
CQ-102C
0.5–5.0 g•cm
Back Tension
(0.01–0.07 oz•inch)
Reverse
CQ-102RC
35–65 g•cm
(0.49–0.90 oz•inch)
Reverse
CA-102RC
0.5–5.0 g•cm
Back Tension
(0.01–0.07 oz•inch)
FF, REW
CQ-201B
60–200 g•cm
(0.83–2.78 oz•inch)
Mode
Torqu Meter
Meter Reading
Forward
CQ-403A
more than 60 g
Reverse
CQ-403R
(more than 2.12 oz)
 Tape Tension  Measurement
set
+
test tape
WS-48A
(3 kHz, 0 dB)
LINE OUT (FRONT)
32 
speed checker
or
frequency counter
– 18 –
TUNER  SECTION
 0dB=1µV
Cautions during repair
When the tuner unit is defective, replace it by a new one because
its internal block is difficult to repair.
[Note]
Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment
2. FM Stereo Separation Adjustment
3. AM (MW) Auto Scan/Stop Level Adjustment
4. FM POLAR Adjustment
FM Auto Scan/Stop Level Adjustment
Setting:
SOURCE button
: FM
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
0.01
µ
F
set
antenna jack (J1)
Procedure:
1. Set to the test mode. (See page 17).
2. Push the SOURCE button and set to FM.
Display
FM
SHUF1
3. Push the preset 3 button.
Display
4. Adjust with the volume RV2 on TU1 so that the “FM” indica-
tion turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV2 so that
put  out light “0” indication and adjustment.
Display
FM
SHUF1
SHUF1
Adjustment Location: See page 21.
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust RV121 (L-CH) and RV221 (R-CH) so that the level meter
reading is –6±1 dB (0.35 to 0.43 V).
Adjustment Location: See page 21.
DOLBY Level Adjustment
Setting:
Preset  3  (PLAY MODE) button: NR OFF
SEL (BAS) button
: Center
SEL (TRE) button
: Center
SEL (BAL) button
: Center
SEL (FAD) button
: Center
SEL (VOL) button
: Maximum
D-BASS control
: OFF
set
+
test tape
P-4-D400
(400Hz, 0dB)
main board
level meter
main board
TP (DOLBY L)/
TP (DOLBY R)
TP (GND)
    
      
– 19 –
FM Stereo Separation Adjustment
Setting:
SOURCE button
: FM
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main: 1 kHz, 33.75 kHz deviation (45%)
  sub: 1 kHz, 33.75 kHz deviation (45%)
19 kHz pilot: 7.5 kHz deviation (10%)
0.01
µ
F
set
antenna jack (J1)
+
LINE OUT (FRONT)
level meter
10 k 
Procedure:
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 28dB
Adjustment Location: See page 21.
AM (MW) Auto Scan/Stop Level Adjustment
Make this adjustment after “FM Auto Scan/Stop Level Adjustment”.
Setting:
SOURCE button
: MW
AM RF signal
generator
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
Output level
: 33 dB (44.7 
µ
V)
(50 
)
set
AM dummy antenna
30 
15 pF
65 pF
antenna jack (J1)
Procedure:
1. Set to the test mode. (See page 17.)
2. Push the SOURCE button and set to MW.
Display
999
MW
SHUF1
3. Push the preset 3 button.
Display
999
MW
SHUF1
3
4. Adjust with the volume RV1 on TU1 so that the “MW” indica-
tion turns to “MW0” indication on the display window.
But, in case of already indicated “MW0”, turn the RV1 so that
put out light “0” indication and adjustment.
Display
999
SHUF1
3
Adjustment Location: See page 21.
– 20 –
FM POLAR Adjustment
Setting:
SOURCE button: FM
FM RF signal
generator
Carrier frequency : 69 MHz
Output level
: 1 mV (60 dB 
µ
)
75 
 coaxial
set
antenna jack (J1)
    
TP (VCO)
main board
frequency counter
+
    
TP (PLT)
main board
level meter
+
–VCO Frequency Adjustment–
1. Tune the set to 69.5 MHz.
2. Connect the frequency counter to the TP (VCO) and adjust the
RV402 for a frequency of 31.25kHz ± 0.1 kHz.
–Sub Carrier Adjustment–
3. Connect the level meter to the TP (PLT), receive the signal of
69.5 MHz (1kHz dev.) and adjust the reading of the level meter
to 0dB.
4. Set the modulation frequency of the FM RF signal generator to
31.25kHz (10kHz dev.) and adjust the L401 so that the output
level is peak of TP (PLT).
5. Adjust the RV401 so that the reading of the level meter to 13
± 0.5dB.
Adjustment Location: See page 21.