Sony XR-C5120 Service Manual ▷ View online
– 13 –
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
•
Torque Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
•
Tape Tension Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
Forward
CQ-102C
0.5 – 4.5 g•cm
Back Tension
(0.01 – 0.06 oz•inch)
Reverse
CQ-102RC
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
Reverse
CQ-102RC
0.5 – 4.5 g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 – 200 g•cm
(0.83 – 2.78 oz•inch)
TEST MODE
<Set the Test Mode>
1. Set the “power select” switch (S501) is “A (ON)” position.
2. Turn ON the regulated power supply. (All LEDs on the set
1. Set the “power select” switch (S501) is “A (ON)” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed)
Note:
Press the
[OFF]
button, if the clock is not displayed.
3. Push the preset
[4]
button.
4. Push the preset
[5]
button.
5. Press the preset
[1]
button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the [OFF] button.
2. Return the “power select” switch (S501) to initially set posi-
1. Push the [OFF] button.
2. Return the “power select” switch (S501) to initially set posi-
tion.
See the adjustment location from on page 14 for the
adjustment.
adjustment.
0 dB=0.775 V
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075 Hz
TAPE DECK SECTION
set
+
–
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
AUDIO OUT jack (J331)
10 k
Ω
speed checker
or
frequency counter
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the speed checker or frequency counter becomes in
specification.
specification.
Specification: Constant speed
Adjustment Location: See page 14.
Tape Speed Adjustment
Setting:
– 14 –
TUNER SECTION
0 dB=1 µV
The tuner section has no adjustment.
Adjustment Location:
– SET UPPER VIEW –
Tape Speed Adjustment
– 15 –
SECTION 6
DIAGRAMS
Note on Printed Wiring Board:
• X
: parts extracted from the component side.
• Y
: parts extracted from the conductor side.
• b
: Pattern from the side which enables seeing.
(The other layers' patterns are not indicated.)
Caution:
Pattern face side:
Pattern face side:
Parts on the pattern face side seen from
(Conductor Side)
the pattern face are indicated.
Parts face side:
Parts on the parts face side seen from
(Component Side)
the parts face are indicated.
Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted. pF: µµF
• All capacitors are in µF unless otherwise noted. pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
and tantalums.
• All resistors are in
Ω
and
1
/
4
W or less unless otherwise
specified.
•
C
: panel designation.
•
U
: B+ Line.
• Power voltage is dc 14.4V and fed with regulated dc power
supply from ACC and BATT cords.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
no mark : FM
(
no mark : FM
(
) : AM
〈〈
〉〉
: TAPE PLAYBACK
∗
: Impossible to measure
• Voltages are taken with a VOM (Input impedance 10 M
Ω
).
Voltage variations may be noted due to normal produc-
tion tolerances.
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
• Signal path.
F
: FM
f
: AM
E
: TAPE PLAYBACK
L
: BUS AUDIO IN
6-1.
NOTE FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS
– 16 –
• Waveforms
– MAIN Board –
– MAIN Board –
1
IC21
1
(XT OUT)
2
IC501
!∞
(XT IN)
3
IC501
!£
(OSC IN)
0.2 Vp-p
97.6 ns
1.7 Vp-p
30.5
µ
s
1.3 Vp-p
54.2 ns
2.7 Vp-p
27
µ
s
– KEY Board –
1
IC901
^º
OSC
Click on the first or last page to see other XR-C5120 service manuals if exist.