DOWNLOAD Sony XR-C4100 Service Manual ↓ Size: 1.03 MB | Pages: 32 in PDF or view online for FREE

Model
XR-C4100
Pages
32
Size
1.03 MB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
xr-c4100.pdf
Date

Sony XR-C4100 Service Manual ▷ View online

– 13 –
GUIDE (C)
2
 guide (C)
1
 three claws
– 14 –
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
Torque Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
 Tape Tension  Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Forward
CQ-102C
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
Reverse
CQ-102RC
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Reverse
CQ-102RC
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 - 200 g•cm
(0.83 - 2.78 oz•inch)
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S801) is “A” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
  Press the 
[OFF]
 button, if the clock is not displayed.
3. Push the preset 
[4]
 button.
4. Push the preset 
[5]
 button.
5. Press the preset 
[1]
 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the 
[OFF]
 button.
2. Return the “power select” switch (S801) to initially set posi-
tion.
Tape Speed Adjustment
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the speed checker or frequency counter becomes in
specification.
Specification: Constant speed
Adjustment Location: See page 17.
See the adjustment location from on page 17 for the
adjustment.
TAPE  DECK  SECTION
0 dB=0.775 V
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075 Hz
+
test tape
WS-48A
(3 kHz, 0 dB)
speed checker
or
frequency counter
 
set
speaker out terminal 
– 15 –
TUNER  SECTION
0 dB=1 µV
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
Note:
  Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment.
2. FM Noise Focus Adjustment.
3. FM Stereo Separation Adjustment.
4. AM (MW) Auto Scan/Stop Level Adjustment.
FM Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
 button: FM
Procedure:
1. Set to the test mode. (See page 14.)
2. Push the 
[SOURCE]
 button and set to FM.
Display
3. Adjust with the volume RV2 on TU1 so that the “FM” indica-
tion turns to “FMI” indication on the display window.
But, in case of already indicated “FMI”, turn the RV2 so that
put  out light “I” indication and adjustment.
Display
Adjustment Location: See page 17.
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
0.01 
µ
F
set
antenna jack (J1)
FM
 
98.0
SHUF1
FM
 
98.0
SHUF1
FM Noise Focus Adjustment
Setting:
[SOURCE]
 button: FM
Procedure:
1. Tune the 98.00 MHz.
2. The then output level is supposing that (A) dB.
3. Adjust with the volume RV3 on TU1 so that the output level is
(A) –32 ±2 dB then signal generator input set to –20 dB.
Adjustment Location: See page 17.
FM Stereo Separation Adjustment
Setting:
[SOURCE]
 button: FM
FM RF signal
generator
Carrier frequency : 98.00 MHz
Output level
: 60 dB (1 mV)
Mode
: stereo
Modulation
: 1 kHz, 75 kHz deviation (100%)
0.01
µ
F
set
antenna jack (J1)
+
speaker out terminal
level meter
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level 
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main: 1 kHz, 20 kHz deviation (22.6%)
sub: 1 kHz, 20 kHz deviation (22.6%)
19 kHz pilot: 7.5 kHz deviation (10%)
0.01 
µ
F
set
antenna jack (J1)
+
speaker out terminal
level meter
Procedure:
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 28 dB
Adjustment Location: See page 17.
– 16 –
AM (MW) Auto Scan/Stop Level Adjustment
Make this adjustment after “FM Auto Scan/Stop Level Adjustment”.
Setting:
[SOURCE]
 and 
[MODE]
 button: MW
Procedure:
1. Set to the test mode. (See page 14.)
2. Push the 
[SOURCE]
 button and set to FM.
3. Push the 
[MODE]
 button and set to MW.
Display
4. Adjust with the volume RV1 on TU1 so that the “MW” indi-
cation turns to “MWI” indication on the display window.
But, in case of already indicated “MWI”, turn the RV1 so that
put out light “I” indication and adjustment.
Display
Adjustment Location: See page 17.
AM RF signal
generator
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
Output level
: 33 dB (44.7 
µ
V)
(50 
)
set
AM dummy antenna
30 
15 pF
65 pF
antenna jack (J1)
MW
INTRO
999
 
SHUF1
INTRO
999
SHUF1
Page of 32