– 13 –
GUIDE  (C)
2
 guide (C)
1
 three claws
– 14 –
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
Torque Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
 Tape Tension  Measurement
Mode
Torque Meter
Meter Reading
Forward
CQ-102C
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Forward
CQ-102C
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
Reverse
CQ-102RC
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Reverse
CQ-102RC
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 - 200 g•cm
(0.83 - 2.78 oz•inch)
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “OFF” mode.
2. Push the preset 
[4]
 button.
3. Push the preset 
[5]
 button.
4. Press the preset 
[1]
 button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the 
[OFF]
 button.
Tape Speed Adjustment
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capastan motor so that
the reading on the speed checker or frequency counter becomes
in specification.
Specification: Constant speed
Adjustment Location: See page 16.
See the adjustment location from on page 16 for the
adjustment.
0 dB= 0.775 V
TAPE  DECK  SECTION
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075Hz
+
test tape
WS-48A
(3 kHz, 0 dB)
speed checker
or
frequency counter
 
set
speaker out terminal
– 15 –
TUNER  SECTION
 0 dB=1 µV
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
Note: 
Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment.
2. FM Stereo Separation Adjustment.
3. AM (MW) Auto Scan/Stop Level Adjustment.
FM Auto Scan/Stop Level Adjustment
Setting:
[SOURCE]
 button: FM
Procedure:
1. Set to the test mode. (See page 14.)
2. Push the 
[SOURCE]
 button and set to FM.
Display
3. Adjust with the volume RV2 on TU1 so that the “FM” indica-
tion turns to “FMI” indication on the display window.
But, in case of already indicated “FMI”, turn the RV2 so that
put  out light “I” indication and adjustment.
Display
Adjustment Location: See page 16.
FM
 
98.0
SHUF1
FM
 
98.0
SHUF1
FM Stereo Separation Adjustment
Setting:
[SOURCE]
 button: FM
Procedure:
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 26dB
Adjustment Location: See page 16.
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level 
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main: 1 kHz, 20 kHz deviation (26.7%)
sub: 1 kHz, 20 kHz deviation (26.7%)
19 kHz pilot: 7.5 kHz deviation (10%)
0.01 
µ
F
set
antenna terminal
+
speaker out terminal
level meter
4  
FM RF signal
generator
Carrier frequency : 98.0 MHz
Output level
: 20 dB (10.0 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
0.01 
µ
F
set
antenna terminal
– 16 –
AM (MW) Auto Scan/Stop Level Adjustment
Make this adjustment after “FM Auto Scan/Stop Level Adjustment”.
Setting:
[SOURCE]
 and 
[MODE]
 button: MW
Procedure:
1. Set to the test mode. (See page 14.)
2. Push the 
[SOURCE]
 button and set to FM.
3. Push the 
[MODE]
 button and set to MW.
Display
4. Adjust with the volume RV1 on TU1 so that the “MW” indi-
cation turns to “MWI” indication on the display window.
But, in case of already indicated “MWI”, turn the RV1 so that
put out light “I” indication and adjustment.
Display
AM RF signal
generator
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
Output level
: 33 dB (44.7 
µ
V)
(50 
)
set
AM dummy antenna
30 
15 pF
65 pF
antenna terminal
MW
INTRO
999
 
SHUF1
INTRO
999
SHUF1
Adjustment Location:
—SET UPPER VIEW–
RV2 FM  Auto Scan/Stop Level Adjustment
RV4 FM  Stereo Separation Adjustment
RV1 AM (MW) Auto Scan/Stop Level Adjustment
Tape Speed Adjustment
TU1
Page of 34