Sony XR-1100 Service Manual ▷ View online
13
XR-1100
2-9.
MAIN BELT, SUB BELT (C)
1
main belt
4
sub belt (c)
2
screw
(PTP2
(PTP2
×
3)
A
2
screw
(PTP2
(PTP2
×
3)
2
screw
(PTP2
(PTP2
×
3)
2
screw
(PTP2
(PTP2
×
3)
3
Lift up the bottom BKT (TS)
in the direction of arrow
in the direction of arrow
A
(as far as the belt can be removed).
14
XR-1100
TAPE DECK SECTION
0 dB= 0.775 V
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
Test Tape
PB Head Azimuth Adjustment
Procedure:
1. Put the set into the FWD PB mode.
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value. Adjust the
screw so that the peak value in channels L and R coincides
within 3 dB.
within 3 dB.
3. Check the phase in the FWD PB mode.
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode
5. Check that output level difference between FWD PB mode
and REV PB mode is within 4 dB.
SECTION 3
MECHANICAL ADJUSTMENTS
SECTION 4
ELECTRICAL ADJUSTMENTS
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 dB
tape speed adjustment
level
meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal
4
Ω
+
–
–
screw
position
position
L-CH
peak
peak
within
3 dB
3 dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
3 dB
3 dB
angle
R-CH
peak
peak
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
–
–
Screen pattern
in phase
good
wrong
45
°
90
°
135
°
180
°
4
Ω
4
Ω
set
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 60 g
Reverse
CQ-403R
(more than 2.12 oz)
• Tape Tension Measurement
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note:
With this set, it is not necessary to apply suitable locking
compound to the parts after the azimuth adjustment.
compound to the parts after the azimuth adjustment.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN•m
Forward
CQ-102C
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Forward
0.15 – 0.39 mN•m
CQ-102C
(1.5 – 4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
2.46 – 5.39 mN•m
Reverse
CQ-102RC
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Reverse
0.15– 0.39 mN•m
CQ-102RC
(1.5 –
4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
4.91 – 14.70 mN•m
FF, REW
CQ-201B
(50 – 150 g•cm)
(0.69 – 2.08 oz•inch)
15
XR-1100
Adjustment Location: PB head
Tape Speed Adjustment
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the frequency counter becomes in 3,015 Hz.
Specified Value: 2,940 to 3,090 Hz
Adjustment Location: See page 17.
FWD
REV
adjustment
screws
screws
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
set
speaker out terminal
–
+
4
Ω
TUNER SECTION
0 dB=1
µ
V
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
cause its internal block is difficult to repair.
Note:
Adjust the tuner section in the sequence shown below.
1. FM Auto Seek/Stop Level Adjustment
2. FM Stereo Separation Adjustment
3. AM Auto Seek/Stop Level Check
2. FM Stereo Separation Adjustment
3. AM Auto Seek/Stop Level Check
FM Auto Seek/Stop Level Adjustment
Setting:
[TUNER]
button: FM
FREQUENCY SELECT switch (E and UK models): FM 50 K
Procedure:
1. Tune the set to 98.0 MHz (E and UK models) or 98.1 MHz
1. Tune the set to 98.0 MHz (E and UK models) or 98.1 MHz
(US and canadian models).
2. Connect the digital voltmeter to TP (SD) on MAIN board.
3. Adjust RV2 on TU100 so that the reading on the digital volt-
3. Adjust RV2 on TU100 so that the reading on the digital volt-
meter changes point from low to high.
Adjustment Location: See page 17.
FM RF signal
generator
dummy
antenna
Carrier frequency : 98.0 MHz (E and UK models)
: 98.1 MHz (US and Canadian models)
Output level
: 28 dB (25.1
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
antenna
jack (CN100)
jack (CN100)
set
50
Ω
50
Ω
0.01
µ
F
+
–
–
TP (SD)
MAIN board
digital
voltmeter
voltmeter
Ver 1.1 2001.06
16
XR-1100
FM Stereo Separation Adjustment
Setting:
[TUNER]
button: FM
FREQUENCY SELECT switch (E and UK models): FM 50 K
Procedure:
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 26 dB
Adjustment Location: See page 17.
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV1 on TU100
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV1 on TU100
for minimum reading.
FM RF signal
generator
Carrier frequency : 98.0 MHz (E and UK models)
: 98.1 MHz (US and Canadian models)
Output level
: 76 dB (6.3 mV)
Mode
: stereo
Modulation
: main: 1 kHz, 33.75 kHz deviation (45%)
sub: 1 kHz, 33.75 kHz deviation (45%)
sub: 1 kHz, 33.75 kHz deviation (45%)
:
19 kHz pilot: 7.5 kHz deviation (10%)
0.01
µ
F
set
antenna jack (CN100)
+
–
–
speaker out terminal
level meter
4
Ω
AM Auto Seek/Stop Level Check
Setting:
[TUNER]
button: AM
FREQUENCY SELECT switch (E and UK models): AM 9 K
Procedure:
1. Tune the set to 999 kHz (E and UK models) or 1000 kHz (US
1. Tune the set to 999 kHz (E and UK models) or 1000 kHz (US
and canadian models).
2. Connect the digital voltmeter to TP (SD) on MAIN board.
3. The reading on the digital voltmeter changes point from low
3. The reading on the digital voltmeter changes point from low
to high.
Adjustment Location: See page 17.
AM RF signal
generator
Carrier frequency : 999 kHz (E and UK models)
: 1000 kHz (US and canadian models)
30% amplitude
modulation by
1 kHz signal
Output level
modulation by
1 kHz signal
Output level
: 33 dB (44.7
µ
V)
±
6 dB
(50
Ω
)
set
AM dummy antenna
30
Ω
15 pF
65 pF
antenna jack (CN100)
+
–
–
TP (SD)
MAIN board
digital
voltmeter
voltmeter
Ver 1.1 2001.06