17
SECTION 3
ASSEMBLY OF MECHANISM DECK
Note : Follow the assembly procedure in the numerical order given.
3-1. HOUSING
3-2. ARM (SUCTION)
7
 Holder the hanger by bending the claw.
1
 Install the catcher to the hanger.
2
 Install the hanger onto
two claws of the housing.
3
 Put the housing
under 
A
 part.
6
 Fit projection on 
D
 part.
4
 Fit claw on 
B
 part.
5
 Fit projection on 
C
 part.
8
 Hold the hanger by
bending the claw.
hanger
housing
D
 part
C
 part
B
 part
A
 part
2
 Move the arm (suction) in the arrow
Direction and fit on projection.
1
 Fit the arm (suction) on the shaft.
projection
18
3-3. LEVER (LDG-A) / (LDG-B)
3-4. GEAR (LOADING FT)
1
 Fit the lever (LDG-A) on
shafts 
A
 to 
C
 and install it.
2
 Fit the lever (LDG-B) on
shafts 
A
 and 
B
 and install it.
3
 type-E stop ring 2.0
shaft 
A
shaft 
C
shaft 
A
shaft 
B
shaft 
B
4
 Align hole in the gear (LDG-D)
with hole the lever (LDG-A).
3
 Move the lever (LDG-B)
in the arrow direction.
2
 tension spring (LD-2)
1
2
 tension spring (LD-1)
6
 polyethylene washer
5
 gear (loading FT)
gear (LDG-D)
gear (LDG-FB)
lever (LDG-A)
hole
hole
19
3-5. GUIDE (C)
3-6. CAPSTAN / REEL MOTOR (M904)
1
 claws
2
 guide (C)
3
 belt (25)
2
 precision screws P 2x3
1
 main motor assy
(CAPSTAN/REEL) (M904)
30
°
20
main board
TP-L
TP-R
test tape
P-4-D400
(400 Hz, 0 dB)
level meter
set
set
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
AUDIO OUT REAR
10 k
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM Auto Scan/Stop Level adjustments can be
performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Turn ON the regulated power supply to ACC and BATT
terminals is “OFF” position (display 1:00).
2. Push the preset  4  button.
3. Push the preset  5  button.
4. Press the preset  1  button for more than two seconds.
5. Then the display and LED on the front panel indicates all lights,
the test mode is set.
<Release the Test Mode>
1. Push the  OFF  button.
PRECAUTION
1. Wipe the following components with an absorbent cotton cloth
moistened with alcohol before adjustment :
PB head
Pinch roller
Idler
Rubber belt
Capstan
2. Demagnetize the PB head using a head demagnetizer.
3. Be careful not to use a magnetized screwdriver.
4. After the adjustment is completed, lock the adjustment parts
using screws.
5. Unless otherwise specified, make adjustments at the specified
voltage (14.4 V).
Torque Measurement
Mode
Torque Meter
Meter Reading
30 – 65 g • cm
FWD
CQ-102C
(0.42 – 0.90 oz • inch)
FWD
0.5 – 4.5 g • cm
Back Tension
(0.01 – 0.06 oz • inch)
30 – 65 g • cm
REV
CQ-102RC
(0.42 – 0.90 oz • inch)
REV
0.5 – 4.5 g • cm
Back Tension
(0.01 – 0.06 oz • inch)
60 – 200 g • cm
FF, REW
CQ-201B
(0.83 – 2.78 oz • inch)
Tape Tension  Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 90 g
REV
CQ-403R
(more than 3.17 oz)
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
  See the adjustment location from on page 23 for the
  adjustment.
  TAPE SECTION
Tape Speed Adjustment
Procedure :
1. Put the set into the FWD PB mode.
Specification : Constant speed
Frequency counter
3,010 to 3,030 Hz
Adjustment Location : Capstan motor internal volume
(See page 23)
DOLBY Level Adjustment
Setting :
Preset  3  (SHUF/
a) button : Light down mark a
(DOLBY OFF)
Procedure :
1. Put the set into the FWD PB mode.
2. Adjust RV100 (L-CH) and RV200 (R-CH) on main board so
that level meter reading is – 6 ± 0.5 dB (0.37 to 0.41 V).
Adjustment Location : See page 23.
0 dB = 0.775 V
Page of 70