Sony MV-900SDS / XVM-R90D Service Manual ▷ View online

XVM-R90D
9
3-5. REAR  COVER (HINGE)
3-6. LCD  BLOCK
4
rear cover 
(hinge)
1
Slide the knob (open) in the direction
of arrow 
A
, and open the LCD block 
in the direction of arrow 
B
.
A
LCD block
B
3
two claws
2
two screws
(P2
 
×
 
8)
rear cover 
(hinge)
3
front cover (hinge)
5
Lifting up the LCD block in 
the direction of arrow 
A
.
2
two connectors 
(CN105, 108)
1
A
2
connector 
(CN107)
2
connector 
(CN103)
4
two screws
(PS3
 
×
 
10)
4
two screws
(PS3
 
×
 
10)
XVM-R90D
10
3-7. LCD  BOARD
3-8. LIQUID  CRYSTAL  DISPLAY  PANEL (LCD1)
5
eight screws
(BTP2
 
×
 
6)
6
screw
(PS2.6
 
×
 
6)
4
two connectors
(CN906, 907)
1
four screws
(B2
 
×
 
5)
2
rear case (LCD)
4
two connectors
(CN905, 908)
7
LCD board
3
flexible board 
(CN801)
4
connector 
(CN850)
1
two screws
(BTP2
 
×
 
6)
4
two screws
(BTP2
 
×
 
6)
5
two retainers 
(LCD)
2
two retainers (LCD)
6
liquid crystal display panel 
(LCD1)
front case (LCD) block
3
shield plate 
(LCD)
11
XVM-R90D
SECTION  4
TEST  MODE
Note:
This set is able to setting the adjustment data, reset to factory default
and initialize the EEPROM (IC402 on the MONITOR board) in the
test mode.
ENTER  THE  TEST  MODE
Procedure:
1. Press the [POWER] button to turn the power ON.
2. While pressing the [VOL --]  and
.
buttons, press the
[RESET] button.
3. The set is enter the test mode and display as bellow figure.
Note:
If initial data is not written to the EEPROM (IC402 on the MONITOR
board) or data is clobbered, the set is not able to display normally
screen.
BATCH  WRITING  OF  THE  INITIAL  DATA  TO
EEPROM
In the test mode, by pressing the [VOL --]  button at two seconds,
batch writing is possible of the initial data to EEPOM (IC402 on
the MONITOR board).
OPERATION  OF  THE  TEST  MODE
All operations are performed using the bellow buttons.
RELEASING  THE  TEST  MODE
In the test mode menu screen, press the [MENU] button to select “8.
SOFT RESET (EXIT)”, and press the [REVERSE] button to release
the test mode.
OPERATING  THE  EACH  ITEM
1. NTSC/PAL SELECT
In this mode, switch the signal format system to NTSC or PAL.
2. FOR FACTORY
In this mode, change the data of adjustment data.
Enter this mode, it displays each adjustment item as follow.
1)
Com Gain
2)
Y Gain
3)
Black Limit
4)
White Limit
5)
R-Sub BRT
6)
B-Sub BRT
7)
R-Sub CONT
8)
B-Sub CONT
9)
Gamma 1
10) Gamma 2
11) VCO Free Run
12) PLL/V Pos
13) H Pos
3. LCD SETTING
This mode is not used in servicing.
4. FM TRANSMITTER
In this mode, switch the frequency range of FM transmitter as
follow.
1) USA (88.3 to 89.9 MHz)
2) Japan (76.5 to 79.5 MHz)
3) Transmitter off
5. HEAT PROTECTION
This mode is not used in servicing.
6. VOLTAGE SETUP
This mode is not used in servicing.
7. LOAD DEFAULT
This mode is not used in servicing.
8. SOFT RESET (EXIT)
Releasing the test mode.
Display
T E S T   M O D E   M E N U
1 .   N T S C / P A L   S E L E C T
2 .   F O R   F A C T O R Y
3 .   L C D   S E T T I N G
4 .   F M   T R A N S M I T T E R
5 .   H E A T   P R O T E C T I O N
6 .   V O L T A G E   S E T U P
7 .   L O A D   D E F A U L T
8 .   S O F T   R E S E T ( E X I T )
                  D r e a m   S y s t e m   2 0 X X
                      V e r . 2 0 X X - X X - X X x
Button
Function
MENU
Select the item
REVERSE
Enter
VOL +
Up the data value
VOL 
Down the data value
12
XVM-R90D
1. DC/DC  CONVERTER  ADJUSTMENT
1-1. Frequency Adjustment
Setting:
Procedure:
1. Connect an oscilloscope or frequency counter to the TP802
and TP804 on the MONITOR board.
2. Check that the voltage between TP951 (
−) and TP952 (+) is
14.4 V. Press the [POWER] button to turn the power on.
3. Adjust the RV801 on the MONITOR board so that the value
of oscilloscope or frequency counter becomes 243 kHz 
±3
kHz.
1-2. 5V Voltage Adjustment
Setting:
Procedure:
1. Connect a digital voltmeter to the TP804 and TP807 on the
MONITOR board.
2. Check that the voltage between TP951 (–) and TP952 (+) is
14.4 V. Press the [POWER] button to turn the power on.
3. Adjust the RV803 on the MONITOR board so that the value
of digital voltmeter becomes 5.05 V 
±0.03 V.
1-3. Other Voltages Check
Setting:
Procedure:
– Vdd Voltage Check –
1. Connect a digital voltmeter to the TP804 and TP808 on the
MONITOR board.
2. Check that the voltage between TP951 (–) and TP952 (+) is
14.4 V. Press the [POWER] button to turn the power on.
3. Check that the value of digital voltmeter is 3.45 V 
±0.2 V.
– Vgh Voltage Check –
4. Connect the digital voltmeter to the TP804 and TP806 on the
MONITOR board.
5. Check that the value of digital voltmeter is 17.5 V 
±1.5 V.
– Vss Voltage Check –
6. Connect the digital voltmeter to the TP804 and TP805 on the
MONITOR board.
7. Check that the value of digital voltmeter is –12.0 V 
±1.5 V.
2. PLL  ADJUSTMENT
Setting:
Procedure:
1. Connect a digital voltmeter to the TP601 and TP602 on the
MONITOR board.
2. Check that the voltage between TP951 (–) and TP952 (+) is
14.4 V. Press the [POWER] button to turn the power on.
3. Adjust the RV601 on the MONITOR board so that the value
of digital voltmeter becomes 2.4 V 
±0.15 V.
3. INVERTER  HIGH  VOLTAGE  CHECK
Setting:
Procedure:
– High Voltage Check –
1. Connect a digital voltmeter (for withstand high voltage) to the
TP853 and TP854 on the MONITOR board.
2. Check that the voltage between TP951 (–) and TP952 (+) is
14.4 V. Press the [POWER] button to turn the power on.
(DIMMER: off)
3. Check that the value of digital voltmeter is 550 V 
±150 V
(rms).
– Frequency Check –
4. Connect an oscilloscope (use a probe for withstand high
voltage) to the TP853 and TP854 on the MONITOR board.
5. Check that the frequency of oscilloscope is 66 kHz 
±2.5 kHz.
4. OSD  DOT  CLOCK  CHECK
Setting:
Procedure:
1. Connect a frequency counter (high impedance) to the TP403
and TP405 on the MONITOR board.
2. Check that the voltage between TP951 (–) and TP952 (+) is
14.4 V.  Press the [POWER] button to turn the power on.
3. Check that the value of frequency counter is 6.5 MHz 
±0.2
MHz.
+
oscilloscope
or
frequency counter
MONITOR board
TP802
TP804
+
digital voltmeter
MONITOR board
TP807
TP804
+
digital voltmeter
MONITOR board
TP805/TP806/TP808
TP804
+
digital voltmeter
MONITOR board
TP601
TP602
+
digital voltmeter
MONITOR board
TP853
TP854
+
frequency counter
MONITOR board
TP403
TP405
SECTION  5
ELECTRICAL  ADJUSTMENTS
Page of 70
Display