– 21 –
OPTICAL  PICK-UP (KMS-241A/J2N)
HOLDER  ASS’Y
4
washer (M)
5
holder ass’y
1
spring (CHKG)
2
stop ring E (1.5)
3
lever (lock R)
3
lever (lock L)
2
stop ring E (1.5)
1
spring (CHKG)
6
bearing (SL)
5
feed screw ass’y
3
screw
(K2 
×
 3)
2
shaft (SL2)
1
two screws
(K2 
×
 3)
7
optical pick-up
(KMS-241A/J2N)
4
screw
(B2 
×
 3)
– 22 –
MOTOR  ASS’Y (M901, M902, M903), SENSOR  BOARD
1
Remove solders of motors
(M901, M902, M903).
3
sensor board
2
two screws
(2 
×
 8)
8
base (SL)
7
screw
(B2 
×
 3)
6
sled motor ass’y
(M902)
5
bracket (SL)
4
screw
(P1.7 
×
 1.8)
screw
(P2 
×
 2.2)
!™
loading motor
ass’y (M903)
0
spindle motor
ass’y (M901)
9
two screws
(P1.7 
×
 1.8)
– 23 –
3. Adjust the volume RV2 on TU1 by turning clockwise untill
“0” is shown next to “FM” on the display window, If “0” is
already shown or the volume RV2 has been turned too far,
turn it back counterclockwise untill “0” is disappeared once,
then try this adjustment.
Display
Adjustment Location: See page 25.
SECTION  3
ELECTRICAL  ADJUSTMENTS
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM Auto Scan/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (SW500) is “A (ON)” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
 Press the
[OFF]
button, if the clock is not displayed.
3. Push the preset 
[4]
 button.
4. Push the preset
[5]
button.
5. Press the preset
[1]
button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the 
[OFF]
 button.
2. Return the “power select” switch (SW500) to initially set po-
sition.
MD  SECTION
MD section adjustments are done automatically in this set.
See the adjustment location from on page 25 for the ad-
justment.
TUNER  SECTION
 0 dB=1µV
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
Note:
 Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment
2. FM Stereo Separation Adjustment (Wide)
3. FM Stereo Separation Adjustment (Narrow)
4. AM Auto Scan/Stop Level Adjustment
FM Auto Scan/Stop Level Adjustment
Setting:
Band: FM
FREQUENCY SELECT switch (E model): FM 200 k
Procedure:
1. Set to the test mode.
2. Push the 
[SOURCE]
 button and set to FM.
Display
set
antenna jack (CNP1)
FM RF signal
generator
Carrier frequency
: 97.9 MHz
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
0.01 
µ
F
SHUF
SHUF
– 24 –
FM Stereo Separation Adjustment (Wide)
Setting:
Band: FM
FREQUENCY SELECT switch (E model): FM 200 k
Procedure:
1. Adjust the volume RV3 on FM/AM tuner unit (TU1) for the
best separation.
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 24 dB
Adjustment Location: See page 25.
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
L-CH
R-CH
Adjust RV3 on TU1
for minimum reading.
R-CH
R-CH
C
R-CH
L-CH
D
FM RF signal
generator
Carrier frequency : 97.9 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main : 1 kHz, 33.75 kHz deviation (45%)
  sub : 1 kHz, 33.75 kHz deviation (45%)
:
 19 kHz pilot: 7.5 kHz deviation (10%)
0.01 
µ
F
set
antenna jack (CNP1)
+
LINE out (Front) 
level meter
10 k
 
AUDIO board 
terminal (CN801) 
(75 
Ω)
FM Stereo Separation Adjustment (Narrow)
Setting:
Band: FM
FREQUENCY SELECT switch (E model): FM 200 k
Procedure:
1. Press 
[SHIFT]
 button.
2. Press 
[4]
 button three times.
3. Press 
[5]
 button twice.
4. Adjust the volume RV4 on FM/AM tuner unit (TU1) for the
best separation.
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 18 dB
Adjustment Location: See page 25.
FM RF signal
generator
Carrier frequency : 97.9 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main : 1 kHz, 20 kHz deviation (26.5%)
  sub : 1 kHz, 20 kHz deviation (26.5%)
:
 19 kHz pilot: 7.5 kHz deviation (10%)
0.01 
µ
F
set
antenna jack (CNP1)
+
LINE out (Front) 
level meter
10 k
 
AUDIO board 
terminal (CN801) 
(75 
Ω)
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
R-CH
L-CH
D