Sony MDX-C800REC (serv.man3) Service Manual ▷ View online
1
SUPPLEMENT-1
File this supplement with the service manual.
Subject : Electrical Adjustments
SERVICE MANUAL
MDX-C800REC
AEP Model
UK Model
E Model
2
TEST MODE
This set has the test mode functionality. The test mode should be
always set before performing adjustments.
always set before performing adjustments.
<Setting the Test Mode>
1. Input the specified voltage (14.4 V) to the ACC and BATT
1. Input the specified voltage (14.4 V) to the ACC and BATT
terminals.
2. “1:00” is displayed on the LCD display.
3. Press 4 key.
4. Press 5 key.
5. Press 1 key for more than 2 seconds.
6. All segments are lit on the LCD display entering the test mode.
3. Press 4 key.
4. Press 5 key.
5. Press 1 key for more than 2 seconds.
6. All segments are lit on the LCD display entering the test mode.
<Releasing the Test Mode>
1. Press OFF key.
1. Press OFF key.
DISPLAY TEST
1. Once the test mode is set, each pressing of the DSPL key will
cause the LCD display to change as follows:
All segments ON
Press DSPL key.
Half segments ON (1)
Press DSPL key.
Half segments ON (2)
(The other half segments that were OFF in (1) are ON.)
(The other half segments that were OFF in (1) are ON.)
Press DSPL key.
All segments OFF
Press DSPL key.
TEST MODE STRUCTURE
1. Set the test mode.
2. Insert a disc and press 5 key.
3. Each time 6 key is pressed, the mode will change as follows:
2. Insert a disc and press 5 key.
3. Each time 6 key is pressed, the mode will change as follows:
ADJUSTMENT mode “SHUF” indication off
Press 6 key.
PLAY mode “SHUF1” indication is lit.
Press 6 key.
REC mode “SHUF2” indication is lit.
Press 6 key.
Unused mode “SHUF ALL” indication is lit.
Press 6 key.
ELECTRICAL ADJUSTMENT
ADJUSTMENT mode: SHUF indication off
Key
Description of test
2
Laser power adjustment mode
3
Traverse adjustment mode
4
Focus bias adjustment mode
5
STOP
6
Switch the mode
ENTER
CLV jitter measurement
DSPL
Select the display
PLAY mode: SHUF1
Key
Description of test
2
Laser power check mode
3
Focus + CLV ON
4
Tracking servo ON/OFF
5
STOP
6
Switch the mode
ENTER
CPLAY mode (middle/outer/inner area)
DSPL
Select the display
REC mode: SHUF2
Key
Description of test
2
Laser power check mode
3
Focus + CLV ON
4
Tracking servo ON/OFF
5
STOP
6
Switch the mode
ENTER
CREC mode (middle/outer/inner area)
DSPL
Select the display
Unused mode: SHUF ALL
3
NOTES FOR ADJUSTMENT
1. Perform the following adjustments as listed when the optical pick-
up and IC400, IC402 and/or IC440 in the MD SERVO board
have been replaced:
(1) Laser power adjustment
(2) Traverse adjustment
(3) Focus bias adjustment
(4) CD error rate check
(5) MO error rate check
have been replaced:
(1) Laser power adjustment
(2) Traverse adjustment
(3) Focus bias adjustment
(4) CD error rate check
(5) MO error rate check
2. Set the test mode to perform these adjustments. Release the test
mode after the adjustments are completed.
3. Perform the adjustments in the order that they are listed.
4. Use the following jigs and measuring equipment:
4. Use the following jigs and measuring equipment:
• Test disc (special disc for playback) TDYS-1
(Part No.: 4-963-646-01)
• Laser power meter LPM-8001
(Part No.: J-2501-046-A)
• Oscilloscope (Measure after the probe is calibrated.)
• Digital voltmeter
• Digital voltmeter
5. When observing multiple signals with an oscilloscope or other
equipment, take care to prevent connection between VC and
ground in the oscilloscope. (Otherwise, VC and ground are
shorted.)
ground in the oscilloscope. (Otherwise, VC and ground are
shorted.)
PREPARING A CONTINUOUSLY RECORDED DISC
• This disc is used for focus bias adjustment and error rate check.
This disc is prepared as follows:
1. Set the test mode. (See page 2.)
2. Insert a commercial disc (blank) and press 5 key.
3. Press 6 key twice to set the REC mode.
2. Insert a commercial disc (blank) and press 5 key.
3. Press 6 key twice to set the REC mode.
(Verify that the “SHUF2” indication is lit on the LCD display.)
4. Verify that no number is displayed at the disc No. indicator.
If any number is displayed, repeatedly press DSPL key until the
number disappears (only two digits are displayed).
number disappears (only two digits are displayed).
5. Press ENTER key three times and verify that there is no disc
number displayed (the disc is recorded from the inner area).
If “3” or “7” is displayed, press ENTER key again to clear the
indicator.
If “3” or “7” is displayed, press ENTER key again to clear the
indicator.
LCD display
6. Record the data until the disc number indicator shows “9” and
then press 5 key to stop recording.
7. Press Z key and take out the disc.
The continuously recorded disc for focus bias adjustment and error
rate check is now prepared.
Note:
Take care to prevent vibrations during continuous recording.
rate check is now prepared.
Note:
Take care to prevent vibrations during continuous recording.
SHUF 2
Disc No. indicator
REC mode
4
KMS-263A
2 7 X 9 3
B 0 8 2 5
2 7 X 9 3
B 0 8 2 5
(Optical pick-up label)
In this case, Iop = 82.5 mA
Iop (mA) = Reading on the digital voltmeter (mV)/1 (
Iop (mA) = Reading on the digital voltmeter (mV)/1 (
Ω
)
For the measurement points, see page 7.
LASER POWER ADJUSTMENT
Connection:
Procedure:
<Setting the write power reference value>
1. Connect a digital voltmeter between TP (I+3V) and TP (IOP).
2. Set the test mode. (See page 2.)
3. Insert a laser power meter into the disc insertion port and press 5
<Setting the write power reference value>
1. Connect a digital voltmeter between TP (I+3V) and TP (IOP).
2. Set the test mode. (See page 2.)
3. Insert a laser power meter into the disc insertion port and press 5
key.
4. Press 2 key.
LCD display
+
–
–
optical pick-up
objective lens
objective lens
laser power
meter
meter
digital voltmeter
MD servo board
TP (I+3V)
TP (IOP)
5. Use DISC + or DISC – key to adjust so that the reading on
the laser power meter is 6.9 to 7.1 mW.
6. Press + > M key for 2 seconds to save the data that has
been set in step 5.
7. Verify that the digital voltmeter reads out the specified value.
Specified value:
Reading on the digital voltmeter: Optical pick-up label indication
value ±10%
Reading on the digital voltmeter: Optical pick-up label indication
value ±10%
Mode No.
(LD Power Adj.)
(LD Power Adj.)
7.0 mW power
<Setting the read power reference value>
8. Press 2 key.
8. Press 2 key.
LCD display
9. Use DISC + or DISC – key to adjust so that the reading on
the laser power meter is 0.69 to 0.71 mW.
10. Press + > M key for 2 seconds to save the data that has
been set in step 9.
11. Press 2 key.
LCD display
Mode No.
(LD Power Adj.)
(LD Power Adj.)
0.7 mW power
12. Verify that the reading on the laser power meter is 6.0 to 6.4
mW.
If outside the specified value, adjust again from step 1.
If outside the specified value, adjust again from step 1.
13. Press 2 key. The laser power adjustment is completed.
Mode No.
(LD Power Adj.)
(LD Power Adj.)
Main beam conversion power
Display