DOWNLOAD Sony MDX-C5960R / MDX-C5970 / MDX-C5970R Service Manual ↓ Size: 5.13 MB | Pages: 66 in PDF or view online for FREE

Model
MDX-C5960R MDX-C5970 MDX-C5970R
Pages
66
Size
5.13 MB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
mdx-c5960r-mdx-c5970-mdx-c5970r.pdf
Date

Sony MDX-C5960R / MDX-C5970 / MDX-C5970R Service Manual ▷ View online

– 13 –
LO  MOTOR  ASS’Y (LOADING)  (M903)
LEVER (LE)  ASS’Y
4
Remove the bracket (LO)
in the direction of the arrow 
A
.
1
Remove solders of motor (M903)
5
LO motor ass’y (loading)
(M903)
2
tension spring (rack)
3
claw
A
2
stopper washer
2
lever (LE) ass’y
3
roller (GLE)
1
– 14 –
HOLDER  ASS’Y
CHUCKING  ARM  ASS’Y
1
Remove the chucking arm ass’y
in the direction of the arrow.
holder ass’y
2
type-E stopring 1.5
2
type-E stopring 1.5
3
lever (lock L)
2
type-E stopring 1.5
2
type-E stopring 1.5
4
Remove the holder ass’y in the
direction of the arrow.
1
spring (CHKG)
1
spring (CHKG)
3
lever (lock R)
– 15 –
OPTICAL  PICK-UP (KMS-241B/J1NP)
SL  MOTOR  ASS’Y (SLED) (M902),  SP  MOTOR  ASS’Y (SPINDLE) (M901)
6
bearing (SL)
5
feed screw ass’y
3
screw
(K2 
×
 3)
2
shaft (SL2)
1
two screws
(K2 
×
 3)
7
optical pick-up
(KMS-241B/J1NP)
4
screw
(B2 
×
 3)
4
screw
(P1.7 
×
 1.8)
5
bracket (SL)
9
two screws
(P1.7 
×
 1.8)
retainer (SP)
SP motor ass’y
(spindle) (M901)
7
screw
(B2 
×
 3)
2
two screws
(2 
×
 8)
3
sensor board
1
Remove solders of motors
(M901, M902)
8
base (SL)
6
SL motor ass’y
(sled) (M902)
– 16 –
SECTION  3
ELECTRICAL  ADJUSTMENTS
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Turn ON the regulated power supply. (The clock is displayed)
Note:
 Press the
[OFF]
button, if the clock is not displayed.
2. Push the preset 
[4]
 button.
3. Push the preset
[5]
button.
4. Press the preset
[1]
button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the 
[OFF]
 button.
MD  SECTION
MD section adjustments are done automatically in this set.
TUNER  SECTION
Note:
Adjust the tuner section in the sequence shown below.
1. FM Auto Scan/Stop Level Adjustment.
2. FM Stereo Separation Adjustmnet.
3. AM (MW) Auto Scan/Stop Level Adjustment.
4. RDS S-Meter Adjustment. (MDX-C5960R/5970R)
FM Auto Scan/Stop Level Adjustment
Setting:
 
[SOURCE]
 button: FM
FREQUENCY SELECT switch: FM 200 k (E model)
Procedure:
1. Set to the test mode.
2. Push the 
[SOURCE]
 button and set to FM.
Display
0 dB=1 µV
See the adjustment location from on page 18 for the ad-
justment.
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
3. Adjust with the volume RV2 on TU1 so that the “FM” indica-
tion turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV2 so that
put  out light “0” indication and adjustment.
Display
*1: MDX-C5960R/C5970R indicate “98.00”.
Adjustment Location: See page 18.
FM Stereo Separation Adjustment
Setting:
 
[SOURCE]
 button: FM
FREQUENCY SELECT switch: FM 200 k (E model)
Procedure:
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specification: Separation more than 30 dB
Adjustment Location: See page 18.
FM RF signal
generator
Carrier frequency: 97.9 MHz (MDX-C5970)
98.0 MHz (MDX-C5960R/C5970R)
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
0.01 
µ
F
set
antenna jack (J1)
FM RF signal
generator
0.01 
µ
F
set
antenna jack (J1)
+
LINE OUT jack (CNP300)
level meter
10 k
MDX-C5970
MDX-C5960R/
C5970R
Carrier frequency
97.9 MHz
98.0 MHz
Output level
60 dB (1 mV)
70 dB (3.2 mV)
Mode
stereo
stereo
main
1 kHz, 33.75 kHz
1 kHz, 16.25 kHz
deviation (45%)
deviation (21.7%)
Modulation
sub
1 kHz, 33.75 kHz
1 kHz, 16.25 kHz
deviation (45%)
deviation (21.7%)
19 kHz
7.5 kHz
7.5 kHz
pilot
deviation (10%)
deviation (10%)
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV4 on TU1
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV4 on TU1
for minimum reading.
SHUF
*1
SHUF
*1
Page of 66
Display