13
CX-LEM300
Tape Speed Check
Mode: Playback
1. Insert the WS-48B into the deck.
2. Press the N button on the deck.
3. Confirm that the frequency counter reads 3,000 ± 90 Hz.
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
3. Mode: Playback
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
Screw
position
L-CH
peak
within
1dB
Output
level
L-CH
peak
R-CH
peak
within
1dB
Screw
position
R-CH
peak
set
test tape
P-4-A100
(10 kHz, – 10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
SPEAKER terminal (J302)
L-CH
+
set
test tape
WS-48B 
(3 kHz, 0 dB)
MAIN board
SPEAKER terminal (J302)
L-CH, R-CH
frequency counter
Record/Playback Head Azimuth Adjustment
Procedure:
1. Mode: Playback
Adjustment Location: Record/Playback/Erase Head
set
MAIN board
SPEAKER terminal (J302)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
Note: Refer to “3-6. Cassette Door Assy” (see page 10)
adjustment screw
14
CX-LEM300
       RFDC signal waveform
Checking Location: CD board (Conductor side)
RFAC Level Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (RFAC) and TP (VC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFAC signal waveform
Checking Location: CD board (Conductor side)
CD  SECTION
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-curve Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (FE) and TP (DVC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in and turned power switch on again
and actuate the focus search. (actuate the focus search when
disc table is moving in and out)
4.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2 ± 1
Vp-p.
S-curve waveform
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: CD board (Conductor side)
RFDC Level Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (RFDC) and TP (DVC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFDC
signal level is correct or not.
Note:
A clear RFDC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
+
CD board
TP (FE)
TP (DVC)
oscilloscope
A
B
symmetry
within 2 
±
 1 Vp-p
+
CD board
TP (RFDC)
TP (DVC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 0.7 
±
 0.2 Vp-p
+
CD board
TP (RFAC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 0.9 
±
 0.4 Vp-p
Checking Location:
– CD BOARD (Conductor Side) –
TP (VC)
TP (FE)
TP (TE)
TP
 (RFDC)
TP
 (DVC)
TP
 (RFAC)
IC103
IC101
15
CX-LEM300
SECTION 6
DIAGRAMS
•  Circuit Boards Location
THIS NOTE IS COMMON FOR PRINTED WIRING
BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed
in each block.)
For schematic diagrams.
Note:
• All capacitors are in µF unless otherwise noted.  pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
f
: internal component.
2
: nonflammable resistor.
1
: fusible resistor.
C
: panel designation.
For printed wiring boards.
Note:
• X
: parts extracted from the component side.
• Y
: parts extracted from the conductor side.
f
: internal component.
: Pattern from the side which enables seeing.
A
: B+ Line.
B
: B– Line.
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal produc-
tion tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: TUNER
J
: CD
d
: AUX
E
: PB (TAPE)
a
: REC (TAPE)
Note: The components identified by mark 
0
 or dotted line
with mark 
0
 are critical for safety.
Replace only with part number specified.
CD board
MAIN board
REGULATOR board
POWER board
CONTROL board
16
CX-LEM300
• Waveforms
– CD Board –
1.1Vp-p
1
 IC103 
qg
(RFAC)
(CD Play Mode)
2
 IC101 
el
(FE)
(CD Play Mode)
200mV/DIV, 1 
µ
s
/DIV
50mV/DIV, 200 
µ
s
/DIV
100mV/DIV, 200 
µ
s
/DIV
1V/DIV, 20ns/DIV
200mVp-p
250mVp-p
3
 IC101 
ra
(TE)
(CD Play Mode)
4
 IC101 
yj
(XTAO)
5.4Vp-p
59ns
6
 IC801 
qh
(8.6MHz-EXTAL)
1V/DIV, 40ns/DIV
1V/DIV, 10 
µ
s
/DIV
5
 IC801 
qd
 (32.768kHz)
5.4Vp-p
30.5 
µ
s
4.0Vp-p
116ns
7
 Q307 collector (Rec mode)
5V/DIV, 4 
µ
s
/DIV
14.1Vp-p
10.7 
µ
s
– CONTROL Board –
– MAIN Board –