DOWNLOAD Sony CDX-602 Service Manual ↓ Size: 2.28 MB | Pages: 42 in PDF or view online for FREE

Model
CDX-602
Pages
42
Size
2.28 MB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
cdx-602.pdf
Date

Sony CDX-602 Service Manual ▷ View online

CDX-602
13
4-3.
GEAR (LOMINI)/(LOAD CAM)  ASSY
gear (LOAD 2)
gear (LOMINI)
marking
Fig. A
chuck plate
2
Attach the gear (LOMINI) at the position 
shown in Fig. A.
shaft (rotary prevention C)
1
Move the lever (LOCK 3A)
fully in the direction of arrow 
B
 
to move the chuck plate up.
B
4
stop ring 1.5 (E type)
3
Attach the gear (LOAD CAM) assy
with its facing inside.
slit
4-4.
OPERATION  CHECK
1
Confirm that the slider moves in the direction of arrow 
C
 to move down
the chuck plate if the gear (LOAD CAM) is rotated in the direction of arrow
A
 or the chuck plate moves up and the slider moves in the direction of
arrow 
D
 if the gear is rotated in the direction of arrow 
B
.
chuck plate
slider
gear (LOAD CAM) assy
A
B
C
D
14
CDX-602
SECTION  5
MECHANICAL  ADJUSTMENT
• Elevator Height (Address) Adjustment
Note:
This adjustments is necessary when the system controller (IC201),
variable resistor (RV201), slider (R), slider (L), or chassis (ELV)
was replaced for any repair.
Connection:
Adjustment Method:
1. Connect this set to the master unit (e.g. MDX-C7970/C7970R),
load a disc magazine, and place the set vertically as shown
below.
2. Connect the regulated power supply to the master unit, and
turn the power on.
3. Press the DISC button on the master unit and select DISC 5.
4. At this time, if the elevator shaft does not position between
comb teeth A and B at addresses 5 and 6 as shown below,
adjust the following.
5. Press repeatedly the DISC + and – buttons on the master unit
so that the elevator shafts moves from address 6 to address 5,
or from 5 to 6. At this time, adjust RV201 on the main board
so that the elevator shaft positions smoothly between comb
teeth A and B.
6. Further, place the set horizontally and make same adjustment
as mentioned above.
7. After adjustment at addresses 5 to 6 is finished, check all op-
erations from addresses 1 to 10 with the set placed vertically
and horizontally respectively to confirm that the elevator shaft
positions in a range between comb teeth A to B.
GND
+
BUS cable
compact disc changer
master unit
CONTROL connector
(CN901)
power supply
(DC 14.4 V)
RV201
comb tooth at address 6
elevator shaft
comb tooth at address 6
comb tooth at address 5
OK
NG
elevator shaft
comb tooth at address 5
A
B
A
B
15
CDX-602
SECTION  6
ELECTRICAL  CHECK
Note:
1. This check is performed with the set placed horizontally.
2. Power supply voltage: DC14.4 V (more than 3 A).
3. Be sure to use the disc “YEDS-18” parts code: 3-702-101-01, but only
when indicated.
Connection:
Focus Bias Check
Connection:
– RF Board (Component Side) –
Procedure:
1. Connect the oscilloscope to TP (RFAC) and TP (VC) on the
RF board.
2. Put the set into play mode by loading the disc (YEDS-18).
3. Confirm that oscilloscope waveform is clear and check RF sig-
nal level is correct or not.
Note:
Clear RF signal waveform means that the shape “
” can be clearly distin-
guished at the center of the waveform.
When observing the eye pattern, set the oscilloscope to AC range
and raise the vertical sensitivity so that it may be easily seen.
GND
+
BUS cable
compact disc changer
master unit
CONTROL connector
(CN901)
power supply
(DC 14.4 V)
RF signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
(10 : 1 probe in use)
level: 1.4 
±
 0.3 Vp-p
oscilloscope
(AC range)
+
TP (VC)
TP (RFAC)
IC101
16
CDX-602
Tracking Offset Check
Connection:
– RF Board (Component Side) –
Procedure:
1. Connect the oscilloscope to TP (TE) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc (YEDS-18).
3. Press the 
[       AMS       ]
 button on the master unit, and check
the traverse waveform*.
4. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
when crossing the track.
A
0 V
A=B
traverse waveform
(100 track jump waveform)
VOLT/DIV: 500 mV
TIME/DIV: 2 ms
Center: 0 V
Traverse waveform
oscilloscope
(DC range)
+
TP (VC)
TP (TE)
IC101
.        >
Page of 42
Display

Click on the first or last page to see other CDX-602 service manuals if exist.