– 14 –
2-10. CHASSIS (OP) (O/S) ASSY
2-11. OPTICAL PICK-UP BLOCK
8 compression spring (FL)
1 tension spring (angle)
2 damper (T)
1 P 2x3
6 chassis (OP) (O/S) assy
7 compression spring (FL)
Fit lever (D) in the
direction of the arrow.
3 damper (T)
Turn loading ring in the
direction of the arrow.
2 sled motor assy
3 optical pick-up block
– 15 –
Procedure :
Adjust for following value reading on digital voltmeter.
Frequency Display
87.5 MHz
107.9 MHz
Reading on Digital voltmeter
1.42 ± 0.05 V
7.2 ± 0.5 V
Adjustment Part
T4
(confirmation)
Adjustment Location : See page 18.
SECTION 3
ELECTRICAL ADJUSTMENTS
TEST MODE
This set have the test mode function. In the test mode, FM Auto Scan/
Stop Level and AM Auto Scan/Stop Level adjustments can be
performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “OFF” mode.
2. Push the preset  4  button.
3. Push the preset  5  button.
4. Press the preset  1  button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test Mode>
1. Push the  OFF  button.
  TUNER SECTION
Cautions during repair
When the tuner unit is defective, replace it by a new one because
its internal block is difficult to repair.
0 dB = 1 µV
FM VT Voltage Adjustment
Setting :
FM/AM button
: FM
Frequency Select switch (E model) : FM 200k
digital
voltmeter
+
FM VT OUT
FM Center Adjustment
Setting :
FM/AM button
: FM
Frequency Select switch (E model) : FM 200k
dummy
antenna
antenna
terminal
50 
50 
set
FM RF signal
generator
dummy
antenna
antenna
terminal
50 
50 
set
FM RF signal
generator
digital
voltmeter
+
IC2 pin 
IC2 pin 
FM CENTER
OUT
(Both side
of R32.)
Procedure :
1. Adjust T5 on TU1 so that the reading on the digital voltmeter
becomes in 0 ± 50 mV.
2. Output an Fcenter 10 dB signal output from FM RF signal
generator so that the LINE OUT REAR jack is –20 dBs.
3. Change the FM RF signal generator frequency and check the
deviation of the frequency on + side and – side when the LINE
OUT REAR jack drops 3 dB. (Both + side and – side is approx.
50 kHz.)
4. Re-adjust T5 on TU1 when the difference deviation of the
frequency does more than 10 kHz.
0 dBs
–3 dBs
(fc–10)
(fc+10)
fc
(kHz)
Adjustment Location : See page 18
Carrier frequency : 98.1 MHz
Output level
: 60 dB (1 mV)
Mode
: mono
Modulation
: 1 kHz, 75 kHz deviation (100 %)
– 16 –
Procedure :
Adjust for following value reading on digital voltmeter.
Frequency Display
530 kHz
1,710 kHz
Reading on Digital voltmeter
1.43 ± 0.05 V
6.8 ± 0.5 V
Adjustment Part
T9
(confirmation)
Adjustment Location : See page 18.
FM  SENS/IF Adjustment
Setting :
FM/AM button
: FM
Frequency Select switch (E model) : FM 200k
antenna
terminal
dummy
antenna
FM RF signal
generator
50 
50 
+
set
LINE OUT REAR
Procedure :
Adjust for a maximum reading on level meter.
T1–T3
87.5 MHz
Adjustment Location : See page 18.
FM Auto Scan/Stop Level Adjustment
Setting :
FM/AM button
: FM
Frequency Select switch (E model) : FM 200k
dummy
antenna
antenna
terminal
50 
50 
set
FM RF signal
generator
digital
voltmeter
FM SD OUT
AM VT Voltage Adjustment
Setting :
FM/AM button
: AM
Frequency Select switch (E model) : AM 10k
dummy
antenna
antenna
terminal
set
level
meter
60 pF
+
30 Ω 15 pF
LINE OUT REAR
digital
voltmeter
+
AM VT OUT
10 k
AM RF signal
generator
10 k
Carrier frequency : 98.1 MHz
Output level
: 22 dB (12.6 µV)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30 %)
Procedure :
1. Adjust RV3 on TU1 so that the reading on the digital voltmeter
changes point from minimum to maximum. (approx. 0.6 V)
2. Confirm that the set stops auto-scanning with FM RF signal
generator output level set at 22 ± 6 dB.
Adjustment Location : See page 18.
level
meter
+
– 17 –
AM IF Adjustment
Setting :
FM/AM button
: AM
Frequency Select switch (E model) : AM 10k
antenna
terminal
set
level
meter
60 pF
+
30 Ω 15 pF
LINE OUT REAR
Procedure :
Adjust for a maximum reading on level meter.
T8
450 kHz
Adjustment Location : See page 18.
antenna
terminal
set
60 pF
+
30 Ω 15 pF
LINE OUT REAR
Procedure :
Adjust for a maximum reading on level meter.
T6, T7
530 kHz
Adjustment Location : See page 18.
AM SD Adjustment
Setting :
FM/AM button
: AM
Frequency Select switch (E model) : AM 10k
antenna
terminal
level
meter
+
AM VT OUT
Procedure :
1. Adjust RV4 on TU1 so that the reading on the digital voltmeter
changes point from minimum to maximum. (approx. 0.6 V)
2. Confirm that the set stops auto-scanning with AM RF signal
generator output level set at 33 ± 4 dB.
Adjustment Location : See page 18.
10 k
10 k
10 k
AM RF signal
generator
dummy
antenna
AM RF signal
generator
dummy
antenna
AM RF signal
generator
dummy
antenna
Carrier frequency : 1000 kHz
30% amplitude
modulation by
400 Hz signal
output level : 30 dB (31.6 µV)
level
meter
+
set
60 pF
30 Ω 15 pF
LINE OUT REAR
AM SENS Adjustment
Setting :
FM/AM button
: AM
Frequency Select switch (E model) : AM 10k
digital
voltmeter
Page of 37