Service Manual
Brand
Device
Audio
File
zs-m30.pdf
Date

Sony ZS-M30 Service Manual ▷ View online

11
ZS-M30
3-10. MD BOARD
3-11. REC BOARD, DETECT BOARD
REC board
Chassis
3
DETECT board
7
Slider
4
Move slider away from pin.
8
Remove solder
   (2 places)
2
Claws
2
Claw
1
Over write head flexible board 
   (CN504)
5
6
Claws
MT-ZSM30-168
Case (MD upper) shield
Case (MD lower) shield
MD board
2
qs
CN601 (2pin)
7
Screws (+P 2.6 X 2.5)
4
Screws, MD fitting
4
Screws, MD fitting
0
Op flexible board
8
Claw
8
Claw
8
Claw
1
Screws (+BVTP 2.6 X 5)
5
9
6
Wire,parallel (9 core)
    REC board (CN505)
qa
Wire,Parallel (7 core)
3
Wire,parallel (22 core)
    Main board (CN807)
12
ZS-M30
Over write head 
(HR901)
3
MD optical pick-up
(KMS-260B)
4
Chassis
1
Screw (+P 1.7X2.5)
6
D SW board
5
Screws (1.4 X 2)
2
Screws (+P 1.4 X 3.5)
3-12. OVER WRITE HEAD (HR901), MD OPTICAL PICK-UP, D SW BOARD
13
ZS-M30
SECTION 4
TEST MODE
Refer to “5. ELECTRICAL ADJUSTMENT” for the test mode of CD section.
4-1. MD SECTION
1. PRECAUTIONS FOR USE OF TEST MODE
• As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc is
stopped before setting and removing it.
Even if the  Z (MD EJECT)  button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc
will not stop rotating.
Therefore, it will be ejected while rotating.
Be sure to press the  Z (MD EJECT)  button after pressing the  NO/CANCEL  button and the rotation of disc is stopped.
1-1. Recording laser emission mode and operating buttons
• Continuous recording mode (CREC MODE)
• Laser power check mode (LDPWR CHECK)
• Laser power adjustment mode (LDPWR ADJUST)
• When pressing the  YES/ENTER  button.
4-2. SETTING THE TEST MODE
1. Set to standby state.
2. Press and hold the  YES/ENTER  button then press MD  u
  t    x   t  u  t   x    .
4-3. RELEASING THE TEST MODE
Remove the power cord to release the test mode.
4-4. BASIC OPERATIONS OF THE TEST MODE
All operations are performed with the following buttons: jogdial  . , >  ,  YES/ENTER  and  NO/CANSEL  .
The functions of these buttons are as follows.
JOG (  >  )
Proceeds the parameter/mode change.
JOG (  .  )
Returns to the parameter/mode change.
YES/ENTER
Goes ahead. Determines the setting/selection.
NO/CANCEL
Suspends.
Function name
 Function
14
ZS-M30
•When selecting test mode, usually the message “TEMP ADJUST” appears. In two rare cases, however, another message may be shown.
1. After conclusion of automatic temperature compensation (starting from display “TEMP = 00”), the message “Disc Insert” appears.
2. The message “Disc Insert” is displayed right form the start.
In both cases press the   YES/ENTER   button while holding the  EDIT   button, thus displaying “TEMP ADJUST” and entering
normal test mode.
In order to cause “TEMP ADJUST” to be displayed whenever test mode is selected, execute the following steps.
1.  Rotate the jog dial until “EEP MODE” is shown.
2. Press the   YES/ENTER   button to display “EEP READ”.
3. Press the   YES/ENTER   button to display “EEP XXXX”.
(The first two “X”-marks represent the address, the latter two the value).
4.  Rotate the jog dial to set the address to 15.
5. Press the   YES/ENTER   button while holding the   EDIT   button.
6. Confirm that the display shows “EEP15XX >XX”.
7. Rotate the jog dial to set the value after the “>”-mark to FF.
8. Press the   YES/ENTER   button.
9. Confirm that the display shows “Complete”.
10.After that, confirm that the display turns to “EEP READ”.
11.Press the   YES/ENTER   button.
12.Confirm that the display shows “EEP15FF”.
13.Press the   NO/CANCEL   button.
4-5. SELECTING THE TEST MODE
There are 9 types of test modes as shown below. The groups can be switched by turn the jog dial. After selecting the
group to be used, press the  YES/ENTER   button. After setting a certain group, turn the jog dial between these modes.
• For details of each adjustment mode, refer to “5. Electrical Adjustments”.
• If a different mode has been selected by mistake, press the  NO/CANCEL  button to release that mode.
• EEP MODE is not used for servicing and therefore are not described in detail. If these modes are set accidentally, press the  NO/CANCEL
button to release the mode immediately. Be especially careful this mode will overwrite the non-volatile memory and reset it, and as a
result, the unit will not operate normally.
TEMP ADJUST
Temperature compensation offset adjustment
LDPWR ADJUST
Laser power adjustment
LDPWR CHECK
Laser power check
LOAD CHECK
load check
S CURVE CHECK
S curve check
EFBAL ADJUST
EF balance adjustment
FBIAS ADJUST
Focus bias adjustment
FBIAS CHECK
Focus bias check
CPLAY MODE
Continuous playback mode
CREC MODE
Continuous recording mode
DETRK CHECK
Detrack check
LOAD AGING
Load aging
EEP MODE
Non-volatile memory control