– 17 –
z
 RF LEVEL and jitter check
Test mode PLAY status
Connection Point : CD board (Conductor side)
Check to see that the jitter is less than 9.0 nsec. and RF level is
between 0.7 – 1.1Vp-p.
SECTION 4
TEST MODE
  CD SECTION
1. Entering CD test mode
Connect power supply cord or insert dry batteries, short Test
point (TEST-1) on the key board. (You need a moment for the
short) (Power button is possible with both of ON or OFF to en-
ter test mode).
The LCD display changes as in the diagram and the unit goes
into test mode.
When you press the u key, the CD rotates and when you press
theu key again, the CD plays (the track servo comes on) (but
no sound is issued).
Pressing the u key starts automatic adjustment and the value
changes, but ignore this value.
[KEY BOARD] (Conductor side)
h
PGM
MEGA BASS
cd
RF level: 
0.7–1.1 Vp-p
VOLT/DIV : 200mV (using 10:1 probe)
TIME/DIV : 500ns
E  C  B
JW610
JW606
D603
D602
R60
7
R606
R605
R604
R603
R602
Q603
S618
JW609
CN806
BAND
x
x
11
(11)
1-678-260-
TEST-1
1
4
TEST-1
SHORT : TEST MODE
OPEN : NORMAL MODE
TP(RF)
IC701
oscilloscope
(AC range)
   TP (RF)
JW741
 (VC)
[CD BOARD]
 
(Conductor side)
2. Exiting test mode
With the unit in test mode, when you press the POWER button
to OFF, power is off and test mode ends.
– 18 –
5-1. MECHANICAL ADJUSTMENTS
 TAPE RECORDER SECTION
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback/erase head
pinch roller
rubber belts
capstan
2. Demagnetize the record/playback/erase head with a head demag-
netizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Torque
Torque Meter
Meter Reading
3.54 to 5.98 mN • m
Forward
CQ-102C
(36 to 61 g • cm)
(0.5 to 0.84 oz • inch)
0.2 to 0.58 mN • m
Forward
CQ-102C
(2 to 6 g • cm)
Back Tension
(0.028 to 0.083 oz • inch)
3.54 to 5.98 mN • m
Reverse
CQ-102RC
(36 to 61 g • cm)
(0.5 to 0.84 oz • inch)
0.2 to 0.58 mN • m
Reverse
CQ-102RC
(2 to 6 g • cm)
Back Tension
(0.028 to 0.083 oz • inch)
5.99 to 14.02 mN • m
FF/REW
CQ-201B
(61 to 143 g • cm)
(0.85 to 1.98 oz • inch)
Tape Tension  Measurement
 Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100g
(more than 3.53 oz)
REV
CQ-403A
more than 100g
(more than 3.53 oz)
SECTION 5
ADJUSTMENTS
z
 TRAVERSE SIGNAL check
Test mode PLAY status
Connection Point : CD board (Conductor side)
Press the M or m from test mode PLAY status.
Check to see that the traverse signal level is between 200 to
500mVp-p.
Note:
Extend the sweep time
for easier view.
200 – 500mVp-p
A
A
B
B
A = B
0V
0V
TP(RF)
IC701
[CD BOARD]
 
(Conductor side)
oscilloscope
(AC range)
IC701 
rg
 pin(TO)
JW741 (VC)
– 19 –
3. Phase Check
Mode : FWD playback
4. Change the reverse playback mode and repeat the step 1 to 3.
5. After the adjustment, lock the adjustment screw with suitable
locking compound.
Adjustment Location : – record/playback/erase head –
V
H
in phase
90
°
45
°
135
°
180
°
good
wrong
set
L-CH
R-CH
screen pattern
test tape
P-4-A100
(10kHz, –10dB)
Osilloscope
LINE OUT
47k
47k
5-2. ELECTRICAL ADJUSTMENTS
 TAPE RECORDER SECTION
0dB = 0.775V
1. The adjustnemts should be performed in the order in the service
manual. (As a general rule playback circuit adjustment should
be completed beforeming recording circuit adjustment.)
2. The adjustments should be performed for bothe L-CH and R-
CH unless otherwise indicated.
Standard Intput Level
Input terminal
LINE IN
source impedance
10k
input signal level
0.5V (–3.8dB)
Standard Output Level
Output terminal
LINE OUT
load impedance
47k
output signal level
0.5V (–3.8dB)
Test Tape
Type
Signal
Used for
P-4-A100
10kHz, –10dB
Azimuth Adjustment
WS-48B
3kHz,
0dB
Tape Speed Adjustment
Record/Playback/Erase Head Azimuth Adjustment
Procedure :
1. Mode : FWD playback
2. Turn the adjustment screw for the maximum output levels. If
these levels do not match, turn the adjustment screw until both
of  output levels match together within 1dB.
set
LINE OUT
47k
level meter
test tape
P-4-A100
(10kHz, –10dB)
L-CH
peak
R-CH
peak
L-CH
peak
R-CH
peak
Screw
position
output
level
within
1 dB
within
1 dB
screw position
FWD side REV side
adjustment screw
– 20 –
 FM Section
RADIO BAND button : FM
Volume : MIN
Adjustment Location : Tuner board (See page 21)
Mechanism deck
Tape speed adjustment
M691 (capstan/reel motor)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450kHz
MW  FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter.
 
Confirmation
  531kHz
Standard value : 0.5 – 1.5V
1,611kHz
Standard value : 4.6 – 5.8V
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 – 1
621kHz
CT3
1,404kHz
 TUNER  SECTION
 AM Section
RADIO BAND button : MW or LW
Volume : MIN
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01 
µ
F
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
set
47k
+
LINE OUT
level meter
0dB = 1
µ
V
Tape Speed Adjustment
Procedure :
– FWD Playback Mode –
set
test tape
WS-48B
(3kHz, 0dB)
frequency counter
LINE OUT
47k
1. Set to FWD playback mode.
2. Adjust M691 (capstan/reel motor) so that the frequency counter
reading becomes 3,000Hz.
    Standard value : 2,970 to 3,030Hz
3. Set to REV playback mode.
Confirm the frequency should be within the standard value.
4. Confirm the frequency difference between beginning and the
end of tape should be within 1.5% (45Hz).
Adjustment Location : M691 (capstan/reel motor)
LW FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter
Confirmation
153kHz
Standard value : 0.2 – 0.9V
L4
279kHz
Adjustment value : 5.0V
Standard value : 4.9 – 5.1V
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 – 2
162kHz
CT5
261kHz
Page of 55