Note:
Follow the assembly procedure in the numerical order given.
4-2.
CD LID ASSY, SPRING (T)
1
Align portion of the spring (T)
with the ditch of the CD lid assy
and install the spring.
with the ditch of the CD lid assy
and install the spring.
ditch
CD lid assy
a
a
portion
4-3.
COVER (CD) SUB ASSY, SPRING (U) AND COLLAR
2
collar
1
spring (U)
cover (CD) sub assy
ZS-D10
14
4-4.
HOW TO INSTALL THE CD LID ASSY
1
Push the collar fully
in the direction of arrow
in the direction of arrow
A
.
2
Align portion
b
of the spring (T)
which has been installed to the CD lid assy
with the ditch of the collar and assemble them.
with the ditch of the collar and assemble them.
portion
b
of spring (T)
ditch
A
3
Pushing the collar fully in the direction of arrow
A
,
rotate the CD lid assy in the direction of arrow
B
one and a half times.
collar
A
B
ZS-D10
15
4-5.
GEAR
3
screw (BVTP2.6
×
8)
2
Align convex part of the the gear
with the ditch of the CD lid assy
and install the gear.
with the ditch of the CD lid assy
and install the gear.
ditch of CD lid assy
cover (CD) sub assy
1
Lid the cover (CD) sub assy
with the CD lid assy.
with the CD lid assy.
4-6.
DAMPER
1
damper
2
two screws
(BVTP2.6
(BVTP2.6
×
8)
16
ZS-D10
AM (MW/LW) IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
( ): Singapore, Australian models
AM VCO VOLTAGE ADJUSTMENT (US, CND, MX)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 (531) kHz
1.0
± 0.05 V
Confirmation
1,710 (1,611) kHz
5.3 (4.8)
± 0.7 V
( ): Singapore, Australian models
AM TRACKING ADJUSTMENT (US, CND, MX)
Adjust for a maximum reading on level meter
L3
620 (621) kHz
CT3
1,400 (1,404) kHz
MW VCO VOLTAGE ADJUSTMENT (AEP, UK, IT, EE)
Frequency Display
Reading on Digital Voltmeter
531 kHz
0.9
± 0.4 V
1,611 kHz
5.2
± 0.5 V
MW TRACKING ADJUSTMENT (AEP, UK, IT, EE)
Adjust for a maximum reading on level meter
L3-1
621 kHz
CT3
1,404 kHz
LW VCO VOLTAGE ADJUSTMENT (AEP, UK, IT, EE)
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
153 kHz
0.6
± 0.2 V
Confirmation
279 kHz
5.0
± 0.1 V
LW TRACKING ADJUSTMENT (AEP, UK, IT, EE)
Adjust for a maximum reading on level meter
L3-2
162 kHz
CT5
261 kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM VCO VOLTAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
108 MHz
3.0
± 0.2 V
Confirmation
87.5 MHz
1.3
± 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment and Connecting Location: TUNER board
(See page 17)
TUNER SECTION
0 dB=1
µ
V
[AM (MW/LW) ]
Setting:
Function: RADIO
Band: AM (US, CND, MX, SP, AUS)
Function: RADIO
Band: AM (US, CND, MX, SP, AUS)
MW or LW (AEP, UK, IT, EE)
[FM]
Setting:
Function: RADIO
Band: FM
Function: RADIO
Band: FM
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level:
as low as possible
modulation by
400 Hz signal
Output level:
as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
+
–
–
level meter
set
3.2
Ω
JACK board
CNP392 pin
CNP392 pin
2
JACK board
CNP392 pin
CNP392 pin
1
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level:
as low as possible
deviation by 1 kHz
signal
Output level:
as low as possible
+
–
–
level meter
JACK board
CNP392 pin
CNP392 pin
2
JACK board
CNP392 pin
CNP392 pin
1
set
3.2
Ω
0.01
µ
F
TUNER board
TP (GND)
TP (GND)
TUNER board
TP (ANT)
TP (ANT)
digital voltmeter
TP (VT)
TP (GND)
100 k
Ω
TUNER board
SECTION 5
ELECTRICAL ADJUSTMENTS
PRECAUTION
1. Setting
MEGA BASS : OFF
Ver 1.1