TA-SA500WR/SA600WR/SA700WR
21
Pin No.
Pin Name
I/O
Description
1 to 5
NO_USE
-
Not used
6
BYTE
I
External data bus width selection signal input terminal
7
CNVss
I
Processor mode selection signal input terminal
8, 9
NO_USE
-
Not used
10
RESET
I
System reset signal input from the reset switch   “L”: reset
11
Xout
O
System clock output terminal (8MHz)
12
Vss
-
Ground terminal
13
Xin 
I
System clock input terminal (8MHz)
14
Vcc1
I
Power supply terminal (+3.3V)
15
NMI
I
For CPU rewrite mode
16, 17
NO_USE
-
Not used
18
AC_CUT
I
AC cut detection signal input terminal   “L”: AC cut
19
LED_POWER
O
Speaker LED driver power control
20
LED_SCL
I/O
Two-way I2C clock bus with speaker LED driver
21
NO_USE
-
Not used
22
LED_SDA
I/O
Two-way I2C data bus with speaker LED driver
23
LED_RESET
O
Speaker LED driver reset
24
KEY_PAIRING
I
SECURE LINK key input terminal
25
LED_GREEN
O
LED drive signal output terminal for LINK/STANDBY indicator (green) indicator   “H”: LED on
26
LED_RED
O
LED drive signal output terminal for LINK/STANDBY indicator (red) indicator   “H”: LED on
27, 28
NO_USE
-
Not used
29
TxD1
O
Transmit data output terminal
30
RxD1
I
Receive data inout terminal
31
ON CHIP DEBUG / 
CLK1
I
On chip debuger / fl ash write CLK1
32
NO USE / RTS1
O
Not used / fl ash write RTS1
33
S-AIR_DATA
I/O
Two-way I2C data bus with the S-AIR wireless transceiver
34
S-AIR_CLK
I/O
Two-way I2C clock bus with the S-AIR wireless transceiver
35
S-AIR_RESET
O
S-AIR reset signal output to the wireless transceiver   “L”: reset
36
NO_USE
-
Not used
37
S-AIR_INT
I
S-AIR interrupt
38
NO_USE
-
Not used
39
EPM
O
EPM signal output terminal
40
P_CONT2 (S-Master)
O
Power on/off control signal output terminal   “H”: on
41
P_CONT1 (S-AIR)
O
Power on/off control signal output terminal   “H”: on
42
P_CONT_PVDD
O
Power on/off control signal output terminal   “H”: on
43
NO_USE
-
Not used
44
CE
I
Chip enable signal input terminal
45 to 59
NO_USE
-
Not used
60
VCC2
-
Power supply terminal (+3.3V)
61
NO_USE
-
Not used
62
VSS
-
Ground terminal
63 to 68
NO_USE
-
Not used
69
PVDD_SD_EN
O
PVDD/Shutdown signal output terminal
70, 71
NO_USE
-
Not used
72
DRIVE_SD
I
Shutdown signal input from the DAMP processor.
73, 74
NO_USE
-
Not used
75
TAS5538_SDA
I/O
Two-way I2C data bus with the DAMP processor
76
TAS5538_SCL
I/O
Two-way I2C clock bus with the DAMP processor
77
TAS5538_XRST
O
Reset signal output to the DAMP processor   “L”: reset
78
TAS5538_XPDN
O
Power down signal output to the DAMP processor   “L”: power down
79
STA516_XPDN
O
Power down signal output to the power amplifi er   “L”: power down
80
STA516_TH_WARN
I
Thermal warning detection signal input from the power amplifi er   “L”: thermal warning
81
DC_DET
I
Speaker DC detection signal input terminal
•  IC Pin Function Description
WLK6-MAIN  BOARD  (1/3)  IC201  R5F36506CDFB#30  (SYSTEM CONTROLLER)
TA-SA500WR/SA600WR/SA700WR
22
Pin No.
Pin Name
I/O
Description
82
TAS5538_MUTE
O
Muting on/off control signal output to the DAMP processor   “L”: muting on
83
MODEL
I
Model setting input terminal  
84
SHIMUKE
Destination setting input terminal   
85, 86
NO_USE
-
Not used
87
KEY_POWER
I
Power key input terminal
88 to 93
NO_USE
-
Not used
94
AVSS
-
Ground terminal
95
NO_USE
-
Not used
96
VREF
Reference voltage (+3.3V) input terminal
97
AVCC
-
Power supply terminal (+3.3V)
98 to 100
NO_USE
-
Not used
23
TA-SA500WR/SA600WR/SA700WR
The components identifi ed  by  mark 
or dotted line with mark 
0 are critical for 
safety.
Replace only with part number specifi ed.
Les composants identifi és par une marque 
0 sont critiques pour la sécurité.
Ne les remplacer que par une pièce por-
tant le numéro spécifi é.
SECTION  5
EXPLODED  VIEWS
Note:
•  -XX and -X mean standardized parts, so 
they may have some difference from the 
original one.
•  Items marked “
*” are not stocked since 
they are seldom required for routine ser-
vice. Some delay should be anticipated 
when ordering these items.
•  The mechanical parts with no reference 
number in the exploded views are not sup-
plied.
•  Color Indication of Appearance Parts Ex-
ample:
  KNOB, BALANCE (WHITE) . . . (RED)
   
 
 
   
 
Parts Color  Cabinet’s Color
• Abbreviation
 AR 
Argentina 
model
 AUS  : 
Australian 
model
 CH 
Chinese 
model
 CND  : 
Canadian 
model
  E3 
: 240 V AC area in E model
  E12 
: 220 – 240 V AC area in E model
  E32 
: 110 – 240 V AC area in E model
  E51 
: Chilean and Peruvian models
 EA 
Saudi 
Arabia 
model
 MX 
Mexican 
model
 MX6  : 
Latin-American 
model
 PX 
PX 
model
 RU 
Russian 
model
 SP 
Singapore 
model
 TH 
Thai 
model
 TW 
Taiwan 
model
5-1.  TOP  COVER  SECTION
 1 
3-077-331-71 +BV3 
(3-CR)
  2 
4-476-172-01  TOP COVER (SA500WR/SA700WR)
  2 
4-476-172-11  TOP COVER (SA600WR)
  3 
1-828-776-61  WIRE (FLAT TYPE) (26 CORE)
  4 
1-492-700-52  RF MODULATOR (WS001)
  5 
X-2589-094-1  FRONT PANEL ASSY [WLK6-B] HB
(SA500WR: EXCEPT US/SA700WR: EXCEPT US)
  5 
X-2589-095-1  FRONT PANEL ASSY [WLK6-B] V2 (US)
  5 
X-2589-096-1  FRONT PANEL ASSY [WLK6-W] HB (SA600WR)
  Ref. No. 
Part No. 
Description 
Remark
  Ref. No. 
Part No. 
Description 
Remark
Note: If wire (fl at type) is replaced, install it after bending 
it in the same form as that before replacement.
Ver. 1.3
WLK6-MAIN board section
1
2
1
3
4
5
24
TA-SA500WR/SA600WR/SA700WR
51
52
52
52
53
58
54
55
56
57
not supplied
not supplied
not supplied
not supplied
58
(SA600WR)
(SA600WR)
5-2.  WLK6-MAIN  BOARD  SECTION
 51 
3-077-331-81 +BV3 
(3-CR)
 52 
3-077-331-71 +BV3 
(3-CR)
  53 
A-1978-587-A  WLK6-MAIN E PC BOARD BOARD, COMPLETE
(SA600WR)
  53 
A-1978-953-A  WLK6-MAIN BOARD, COMPLETE (SA500WR)
  53 
A-1980-261-A  WLK6-MAIN BOARD, COMPLETE (SA700WR)
  54 
1-474-549-11  REGULATOR, SWITCHING (R68-2353A) (MX, PX)
  54 
1-474-549-21  REGULATOR, SWITCHING (R68-2354A)
(SA700WR: US)
  54 
1-474-549-31  REGULATOR, SWITCHING (R68-2355A)
(SA700WR: AEP, UK, SP)
  54 
1-474-549-52  REGULATOR, SWITCHING (R68-2356A)
(E32, MX6, E51)
  54 
1-474-549-62  REGULATOR, SWITCHING (R68-2357A)
(SA500WR: US, CND, TW/SA600WR: TW)
  54 
1-474-549-72  REGULATOR, SWITCHING (R68-2358A)
(SA500WR: AEP, UK, RU, EA, SP, AR,
TH, AUS, CH/
SA600WR: AEP, UK, RU, EA, SP, AR,
TH, AUS, CH)
  54 
1-474-549-82  REGULATOR, SWITCHING (R68-2358B) (E3, E12)
0 55 
4-966-267-12  BUSHING (FBS001), CORD
0 56 
1-834-966-41  POWER-SUPPLY CORD
(AEP, RU, E3, SP, E32, MX6, E51, PX)
0 56 
1-835-068-21  CORD, POWER (AUS)
0 56 
1-837-308-11  CORD, POWER-SUPPLY (US, CND)
0 56 
1-837-312-11  CORD, POWER-SUPPLY (AR)
0 56 
1-837-344-11  CORD, POWER-SUPPLY (MX)
0 56 
1-837-345-11  CORD, POWER-SUPPLY (TW)
0 56 
1-837-822-21  CORD, POWER-SUPPLY (CH)
0 56 
1-839-012-11  CORD, POWER-SUPPLY (E12)
0 56 
1-839-940-21  POWER-SUPPLY CORD (TH)
0 56 
1-839-999-21  POWER-SUPPLY CORD (SA500WR: UK, EA/
SA600WR: UK, EA/SA700WR: UK)
0 57 
1-770-019-71  ADAPTOR, CONVERSION PLUG 3P
(SP for Hong Kong model)
 58 
4-295-590-01 FOOT
  Ref. No. 
Part No. 
Description 
Remark
  Ref. No. 
Part No. 
Description 
Remark
Ver. 1.3