DOWNLOAD Sony STR-K402 Service Manual ↓ Size: 13.12 MB | Pages: 34 in PDF or view online for FREE

Model
STR-K402
Pages
34
Size
13.12 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
str-k402.pdf
Date

Sony STR-K402 Service Manual ▷ View online

5
STR-K402
6
STR-K402
SECTION 2
TEST MODE
SOFTWARE VERSION DISPLAY MODE
* The software version is displayed.
* Procedure:
While depressing the TUNER and the VIDEO buttons
simultaneously, press the power  ?/1  button to turn on the main
power.  The model name, destination and the software version are
displayed.
FLUORESCENT INDICATOR TUBE TEST MODE
* All fluorescent segments are tested.  When this test is activated,
all segments turn on at the same time, then each segment turns on
one after another.
* Procedure:
While depressing the TV/SAT and the DVD/LD buttons
simultaneously, press the power  ?/1  button to turn on the main
power.
1. All segments turn on.
NAME  , SURR and SOUND FIELD MODE LED turn on.
2. Press the VIDEO button, confirm display
Digital Cinema Sound, SET UP and 2CH LED turn on.
3. Press the  VIDEO button, confirm display
MULTI CHANNEL DECODING(blue), LEVEL and A.F.D.
LED turn on.
4. Press the  VIDEO button, All segments turn off.
5. Every pressing of the VIDEO button turns on each segment and
LED one after another in the same order.
(Not only the VIDEO button, but also the other buttons such as
DVD/LD , TV/SAT , MD/TAPE , CD , TUNER can be used.)
FACTORY SET MODE
* All preset contents are reset to the default setting.
* Procedure:
While depressing the VIDEO and the CD buttons simultaneously,
press the power  ?/1  button to turn on the main power.  The
message FACTORY appears and switch off the set.
While depressing the VIDEO and the CD buttons simultaneously,
press the power  ?/1  button again. The message FACTORY
appears and the present contents are reset to the default values.
SOUND FIELD CLEAR MODE
* The preset sound field is cleared when this mode is activated.
Use this mode before returning the product to clients upon
completion of repair.
* Procedure:
While depressing the SOUND FIELD MODE button, press the
power  ?/1  button to turn on the main power.  The message
S. F. CLR appears and initialization is performed.
AM CHANNEL STEP 9 kHz/10 kHz
SELECTION MODE
* Either the 9 kHz step or 10 kHz step can be selected for the AM
channel step.
* Procedure:
Set the FUNCTION to AM.  Turn off the main power.
While depressing the  TUNING+ button or the
PRESET TUNING+ button, press the power  ?/1  button to turn
on the main power.  Either the message 9 k STEP or 10 k STEP
appears.  Select the desired step.
KEY CHECK MODE
* Button check
* Procedure:
While depressing the SURR and the A.F.D buttons simultaneously,
press the power  ?/1  button to turn on the main power.
“REST 36” appears.
Every pressing of any button other than  ?/1  counts down the
buttons.  The buttons which are already counted once are not
counted again.  When all buttons are pressed “REST 00” appears.
When MASTER VOLUME is rotated in clockwise direction,
“VOL MIN”, “VOL 1” to “VOL 30”, “VOL MAX” appear.
SW
L
SL
C
R
S
SR
SLEEP
SP.OFF
( ( ( L F E ) ) )
DIGITAL
OPT COAX MULTI CH IN
PRO LOGIC DTS MPEGSTEREO MONO RDS
MEMORY
MUTING
INFO
NEWS
TA
EQ
D.RANGE
D D
dB
kHz
mft.
MHz
SW
L
R
S
SLEEP
 L F E 
COAX
PRO LOGIC
MPEGSTEREO
RDS
MUTING
INFO
TA
D.RANGE
D D
k    
m   
MHz
SL
C
SR
SP.OFF
( ( (       ) ) )
DIGITAL
OPT
MULTI CH IN
DTS
MONO
MEMORY
NEWS
EQ
dB
  Hz
   ft.
7
STR-K402
SECTION 3
DIAGRAMS
For schematic diagrams.
Note:
• All capacitors are in 
µ
F unless otherwise noted.  pF: 
µµ
F
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
%
: indicates tolerance.
f
: internal component.
2
: nonflammable resistor.
1
: fusible resistor.
C
: panel designation.
A
: B+ Line.
B
: B– Line.
H
: adjustment for repair.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
No mark : FM
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal production
tolerances.
• Waveforms are taken with a oscilloscope.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: CD
THIS NOTE IS COMMON FOR PRINTED WIRING
BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this necessary note is printed in each
block.)
• Waveform
– DISPLAY BOARD –
– DIGITAL BOARD –
C
B
These are omitted.
E
Q
B
These are omitted.
C
E
1
 IC102 
id
 
5.8Vp-p
63ns
2
 IC1005 
7
 
5.8Vp-p
81ns
For printed wiring boards.
Note:
• X
: parts extracted from the component side.
a
: Through hole.
f
: internal component.
• b
: Pattern from the side which enables seeing.
The components identified by mark 
0
 or dotted
line with mark 
0
 are critical for safety.
Replace only with part number specified.
8
STR-K402
3-1. CIRCUIT BOARDS LOCATION
STANDBY board
POWER SW board
HP board
DISPLAY board
MAIN board
VIDEO board
DIGITAL board
Page of 34
Display

Click on the first or last page to see other STR-K402 service manuals if exist.