DOWNLOAD Sony STR-DA1000ES / STR-DB790 Service Manual ↓ Size: 11.06 MB | Pages: 104 in PDF or view online for FREE

Model
STR-DA1000ES STR-DB790
Pages
104
Size
11.06 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
str-da1000es-str-db790.pdf
Date

Sony STR-DA1000ES / STR-DB790 Service Manual ▷ View online

13
STR-DA1000ES/DB790
3-6.
DIGITAL  BOARD
3-7.
STAY3/STAY4/SP-B/SP-A/S-VIDEO/VIDEO/VIDEO-AU/AU-IN  BOARD
3
connector
(CN1107)
1
connector (CN1110)
2
connector (CN1106)
5
digital board
4
two connectors
(CN402, 403)
8
SP-B board
0
SP-A board
6
STAY4 board
3
STAY3 board
qs
S-video board
5
connector (CN451)
4
connector (CN450)
7
two connectors (CN412, 413)
9
two connectors (CN410, 411)
qa
connector (CN408)
qg
connector (CN406)
ql
AU-IN board
qh
video-AU board
qj
harness (CN132)
qk
connector (CN404, 405)
2
connector (CN447)
1
connector (CN104)
qd
connector (CN407)
qf
video board
14
STR-DA1000ES/DB790
3-8.
MAIN  BOARD
9
heatsink block
0
main board
8
twelve screws
2
two connectors
 (DA1000ES: CN2701, 2703/
DB790: CN2704, 2705)
1
six connectors (CN421, 401, 601, 651, 501, 420)
3
connector (CN951)
5
connector (CN423)
6
connector (CN416)
7
connector (CN409)
4
A-class board
15
STR-DA1000ES/DB790
FLUORESCENT INDICATOR TUBE PATTERN
CHECK MODE
All fluorescent segments are tested. When this test is activated, all
segments turn on at the same time, then each segment turns on one
after another.
Procedure:
1. While pressing the 
[DISPLAY]
 and 
[MEMORY/ENTER]
 but-
tons, press the
I
/1
button to turn on the main power.
2. All segments and 
[MULTI CHANNEL DECODING]
 indicator
LED turn on.
3. Turn the 
[INPUT SELECTOR]
 dial.
4. Half of segments turn on and 
[MULTI CHANNEL DECOD-
ING]
 indicator LED turn off.
5. Turn the 
[INPUT SELECTOR]
 dial once again.
6. Others half of segments and 
[MULTI CHANNEL DECODING]
indicator LED turn on.
7. Turn the 
[INPUT SELECTOR]
 dial once again.
8. All segments and 
[MULTI CHANNEL DECODING]
 indicator
LED turn off.
KEY CHECK MODE
When this mode is used, the destination and the software version
number are displayed.
Procedure:
1. While pressing the 
[MAIN MENU]
 and 
[DISPLAY]
 buttons,
press the
I
/1
button to turn on the main power.
2. The message “REST 14” appears.
3. Every pressing of any button other than the
I
/1
button counts
down the buttons. The buttons which are already counted once
are not counted again.
4. When all buttons are pressed, the message “REST 00” appears.
SHIPMENT  MODE
All preset contents are cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
Procedure:
1. While pressing the  
[TUNING +]
 and 
[MUSIC]
 buttons, press
the
I
/1
button to turn ton the main power.
2. The memories are reset to the default values and the main power
turn off automatically after seven minutes.
SECTION  4
TEST  MODE
TUNER FACTORY PRESET MODE
All preset contents are reset to the default setting.
Procedure:
1. While pressing the 
[SURR BACK DECODING]
  and 
[PRE-
SET TUNING --]
 buttons, press the
I
/1
button to turn on the
main power.
2. The message “FACTORY” appears and the present contents
are reset to the default values.
TUNER AM STEP CHANGE (9 kHz/10 kHz) MODE
(STR-DA1000ES)
Either the 9 kHz step or 10 kHz step can be selected for the AM
channel step.
Procedure:
1. Press the
I
/1
button to turn on the main power.
2. Turn the 
[INPUT SELECTOR]
 dial to select the “AM”
3. Press the
I
/1
button to turn off the main power.
4. While pressing the 
[PRESET TUNING +]
 or 
[TUNING +]
 but-
ton, press the  
I
/1
button to turn on the main power.
5. Either the message “9 K STEP” or “10 K STEP” appears. Se-
lect the desired step.
TUNER AUTOBETICAL TUNING MODE
(STR-DB790: AEP and UK models)
Procedure:
1. While pressing the 
[MEMORY/ENTER]
  button, press the
 
I
/1
button to turn on the main power.
2. The message “AUTO-BETICAL SELECT” appears and scans
and stores all the FM and FM RDS stations in the broadcast
area.
3. When done, the message “FINISH” appears.
SOUND FIELD CLEAR MODE
The preset sound field is cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
Procedure:
1. While pressing the 
[MUSIC]
 button, press the
I
/1
button to
turn on the main power.
2. The message “SF. CLR.” appears and initialization is
performed.
ALL CLEAR MODE
All preset contents are cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
Procedure:
1. While pressing the 
[INPUT MODE]
 and 
[MEMORY/ENTER]
buttons, press the
I
/1
button or press the
I
/1
button for more
than five seconds to turn on the main power.
2. The message “INITIAL” appears and the memories are reset
to the default values.
VOLUME  CHECK  MODE
Procedure:
1. Enter the swap mode. (Refer to the “DSP TEST MODE” (see
page16))
2. Press the  
[DISPLAY]
 button.
3. The massage “–oodB” appears. (Volume level is “MIN”)
4. Press the  
[DISPLAY]
 button once again.
5. The message “–58.0dB” appears. (Volume level is “MID”)
6. Press the  
[DISPLAY]
 button once again.
7. The massage “0.0dB” appears. (Volume level is “MAX”)
16
STR-DA1000ES/DB790
DSP TEST  MODE
Procedure:
1. Press the 
I
/1
button to turn on the main power, then while pressing the  
[MEMORY/ENTER]
 button, press the 
[SURR BACK DE-
CODING]
 button.
2. The message “SPECIAL” appears.
3. Each time the 
[MENU]
 dial is turned clockwise, the item is switched in order as follows .
Items
Display
Remark
Destination and software
****
 XXX
****
: destination, XXX: software version
Model name
DA1000 or DB790
Never change (IF changed, INITIALIZE works every AC on)
Destination change
DES. XXXX
XXXX: destination
Command mode change
C.MODE.AV1 or C.MODE.AV2
Volgate limiter working level
V.LIM. > XX
Never change
Power control after protector on
PROT.EVER or PROT.OFF
When PROTECTOR works, system power is automatically
down after 5 sec for safety (Set “Ever On” for the servicing)
SWAP
SWP. XXXX
Switching with 
[--/+]
 dial
Bass management
BM. XXXX
AUTO, OFF, 1 to 28 (switching with 
[--/+]
 dial)
Co-ef. Read address
RA.12XXX
Turn the 
[--/+]
 dial to switch the read data address
Co-ef. Read data
RD.XXXXXX xx
Value is read data
Co-ef. Write address
WA.12XXX
Turn the 
[--/+]
 dial to switch the write data address
Co-ef. Write data
WD.XXXXXX xx
Turn the 
[--/+]
 dial to set the write data
Total operation time
TTL-XXXX xx
4 large character is hour, 2 small character is minutes
Longest power on time
LNG-XXXX XX
Volume 
I – 50 dB time display
V50-XXXX XX
Volume 
I – 40 dB time display
V40-XXXX XX
Volume 
I – 30 dB time display
V30-XXXX XX
Volume 
I – 20 dB time display
V20-XXXX XX
Volume 
I – 10 dB time display
V10-XXXX XX
Volume 
I 0 dB time display
V00-XXXX XX
Protector count value
PROT XXX
0 to 255
EEPROM condition
E-XXXXX
S RST (super reset, first time use EEPROM, test pattern
corrupted) FAIL (EEPROM read/write with microprocessor
have problem)
V CHG (software version change)
D CHG (destination/model change)
CLEAR (back up data initialize)
NORM (normal AC on)
EEPROM read
E-XXX-XX
First four hex code is EEPROM address
Last two hex code is EEPROM data
EEPROM super reset
S.RST-YES or S.RST-NO
Not used for the servicing
When EEPROM initialization is required, perform the “all clear
mode” (see page 15)
Ver 1.3
Page of 104
Display

Click on the first or last page to see other STR-DA1000ES / STR-DB790 service manuals if exist.