DOWNLOAD Sony SRF-DR2000 Service Manual ↓ Size: 3.98 MB | Pages: 23 in PDF or view online for FREE

Model
SRF-DR2000
Pages
23
Size
3.98 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
srf-dr2000.pdf
Date

Sony SRF-DR2000 Service Manual ▷ View online

– 5 –
– 6 –
SECTION 2
DISASSEMBLY
Note :
 Follow the disassembly procedure in the numerical order given.
2-1. CABINET (REAR) REMOVAL
2-2. MAIN BOARD REMOVAL
r
 The equipment can be removed using the following procedure.
Cabinet (Rear)
MICOM board, LCD1
Main board
Set
2
 Screws (1.7x10)
1
3
4
5
6
7
8
Cabinet (Rear)
Cabinet (Front)
Lid, battery case
Claws
Claws
5
 Removal solder
1
3
4
2
Claws
Claw
Main board
– 7 –
2-3. MICOM BOARD, LCD1 REMOVAL
3
4
2
Claw
MICOM board
Claws
Cabinet (Front)
1
 Screws (1.7x5)
8
9
0
5
6
7
MICOM board
Holder (LCD)
LCD1
– 8 –
Adjustments Location :
SECTION 3
ELECTRICAL ADJUSTMENTS
FM Section
Setting :
VOLUME
: Maximum
1. Connect a capacitor (10
µ
F) between pin 1 of IC403 and ground.
2. Adjust RV401 for 76.2kHz – 75.8kHz reading on the frequency
counter.
• Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally the trimmer capacitors.
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
CT402
98.0MHz
FM VCO  Adjustment
Procedure :
FM RF signal
generator
TP FM IN
(BPF401 
1
 pin)
22.5kHz frequency 
deviation by 400Hz signal.
Output level : 
as low as possible
0.01  F
µ
set
16
phones jack
level meter
T401 : FM IF Alignment
RV401 : VCO Adjustment
CT402 : FM Tracking Adjustment
[MAIN BOARD]
(Side A)
IC403
RV401
1
5
6
10
R418
R428
76K
0.01
µ
F
1pF
10 
µ
F
DC5V
2.4k
1M
S
2SK193-E
Servicing tool
frequency counter
[MAIN BOARD] (Side A)
FM IF ALIGNMENT
Adjust for a maximum reading on level meter.
T401
10.7MHz
Page of 23
Display