21
SCD-XA333ES
Items
Description
Remarks
HENSIN
Eccentricity measurement
For the CD only are measured
Eccentricity (actual eccentric amount) of disc, disc pulley total
• Read by dividing by 10
• 0 may be displayed if eccentricity
is small (10um or less) (Due to
measurement reason)
SPIN DOWN TIME (msec)
Time from spindle brake application to rotation stop
FG (IC901 pin ys) monitoring
FG LEVEL [STEP]
FG value of dics inner position
LOAD OUT TIME (msec)
Time until loading table comes out from the state where a disc is in chuck
Loading out switch    H
tL
Measured Data Reading Method:
To judge the check result, the measured data must be read.
1. When “AUTO CHECK OK” is displayed, rotate the 
[        AMS        ]
 dial clockwise by 2 clicks.
2. When “13. DISP RSLT?” is displayed, press the 
[        AMS        ]
 dial to enter.
3. “PLEASE WAIT” will be displayed and in several seconds, “13. DISP RESULT” will be displayed.
4. Rotate the 
[        AMS        ]
 dial clockwise by 1 click, and the “LOAD IN” will be displayed.
5. Press the 
[        AMS        ]
 dial to enter. The LOAD IN TIME measured value will be displayed.
6. Compare the displayed value with the following specified value.
7. Hence, repeat step 4 to 6 (display is variable) and read the measured data respectively.
8. Compare the measured data with the specified value to check for NG item.
Note:
Blank display of measured value means that an error occurred during the checking or no measurement was taken place.
Specified Value:
(1) SACD (Use the test disc SATD-S5 or SATD-S4)
Note:
Measured values in check items are typical ones.
Check items
Specified value
LOAD IN TIME (msec)
:
3000 msec or less
SPIN UP TIME (msec)
: 1652
3000 msec or less
RF/VC/FE/TE AVRG (ORG)
: 98, C, 1DE, 0
RF: 7E-9E, VC: 1F1-10, FE: 1B8-42, TE: 1BB-5C
RF/VC/FE/TE AVRG (ADJ)
: 9F, C, 4, 0
RF: 98-A5, VC : 1F1-10, FE: 1F1-10, TE: 1F1-10
PI/TRVS PP (ORG/ADJ)
: 81, 131, 78, 105
PI ORG: 70-89,  PI ADJ: 122-135, TRVS ORG: 68-114, TRVS ADJ: 55-100
PIOR/CCR/TRCR
: 1A, 31, 1F
No specified value given
FOCUS/TRK GAIN
: 2E, 24
FOCUS: 10-40, TRK: 10-40
FBIAS/TRVSC/TRCR2/CFR
: 2,13, 6, 60
F.BIAS: 1D0-4F, TRVSC: 1D0-30    TRCR2, CFR: no specified value given
READ TOC TIME (msec)
: 1283
2200 msec or less
PSP AMPLITUDE
: 1666
1300 or above
1/3 SEEK TIME
F) AVE/MIN/MAX (msec)
: 967, 928, 990
AVE: 1100 msec or less, MAX: 1300 msec or less
R) AVE/MIN/MAX (msec)
: 974, 933, 993
AVE: 1100 msec or less, MAX: 1300 msec or less
1/MAX SEEK TIME
F) AVE/MIN/MAX (msec)
: 1958, 1938, 1968
AVE: 2200 msec or less, MAX: 2500 msec or less
R) AVE/MIN/MAX (msec)
: 1915, 1909, 1935
AVE: 2200 msec or less, MAX: 2500 msec or less
ERROR RATE
PO MAX/AVE FRAME
: 0, 0
No specified value given
PO MAX/AVE NUM
: 160, 3
MAX: 1000 or less, AVE: 100 or less
PI1 MAX/AVE FRAME
: 0, 0
No specified value given
PI1 MAX/AVE NUM
: 242, 17
MAX: 1000 or less, AVE: 100 or less
PI2 MAX/AVE FRAME
: 0, 0
No specified value given
PI2 MAX/AVE NUM
: 128, 2
MAX: 1000 or less, AVE: 100 or less
SPIN DOWN TIME (msec)
: 1342
2500 msec or less
FG LEVEL [STEP]
: 82
100 or less
LOAD OUT TIME (msec)
:
3000 msec or less
l
L
l
L
l
L
l
L
* Items are not used in the
SATD-S5.
22
SCD-XA333ES
(2) CD (Use the test disc PATD-012 or YEDS-18)
Note:
Measured values in check items are typical ones.
Check items
Specified value
LOAD IN TIME (msec)
:
3000 msec or less
SPIN UP TIME (msec)
: 1372
2500 msec or less
RF/VC/FE/TE AVRG (ORG)
: 98, C, 1D6, 4
RF: 7E-9B, VC: 1F1-10, FE: 1B8-42, TE: 1BB-5C
RF/VC/FE/TE AVRG (ADJ)
: 9F, A, 1FF, 4
RF: 98-A5, VC: 1F1-10, FE: 1F1-10, TE: 1F1-10
PI/TRVS PP(ORG/ADJ)
: 81, 131, 95, 92
PI ORG: 70-89,  PI ADJ: 122-135, TRVS ORG: 70-120, TRVS-ADJ: 70-120
PIOR/CCR/TRCR
: 1A, 11, 1F
No specified value given
FOCUS/TRK GAIN
: 2E, 2D
FOCUS: 20-40, TRK: 20-40
FBIAS/TRVSC/TRCR2/CFR
: 0, 10, 5, A0
F.BIAS: 1E0-30,  TRVSC: 1F0-10    TRCR2, CFR: no specified value given
MIN JITTER AT F.BIAS
: 94
100 or less
READ TOC TIME (msec)
: 1410
2500 msec or less
1/3 SEEK TIME
F) AVE/MIN/MAX (msec)
: 824, 804, 850
AVE: 1000 msec or less, MAX: 1200 msec or less
R) AVE/MIN/MAX (msec)
: 850, 833, 860
AVE: 1000 msec or less, MAX: 1200 msec or less
1/MAX SEEK TIME
F) AVE/MIN/MAX (msec)
: 2086, 1999, 2151
AVE: 2300 msec or less, MAX: 2500 msec or less
R) AVE/MIN/MAX (msec)
: 1805, 1793, 1835
AVE: 2300 msec or less, MAX: 2500 msec or less
ERROR RATE
C1 MAX/AVE
: 3, 0
C1  MAX: 15 or less
C2 MAX/AVE
: 0, 0
C2  MAX: 0
HENSHIN RYOU (1/10um)
: 89
800 or less (100 um or less)
SPIN DOWN TIME (msec)
: 1272
2000 msec or less
FG LEVEL [STEP]
: 82
100 or less
LOAD OUT TIME (msec)
:
3000 msec or less
Note:
RF, VC, FE, TE, FBIAS and TRVSC measured values are hexadecimal data with positive and negative signs. When comparing the measured
value with the specified value, refer to the following.
Hexadecimal (hex) display 9 bit data
FF
011111111 (+255) 
FE
011111110 (+254) 
(+) Side
(-) Side
MAX
01
000000001 (+1) 
00
000000000 (0) 
1FF
111111111 (-1) 
101
100000001 (-255) 
100
100000000 (-256) 
Hexadecimal (hex) display 8 bit data
7F
01111111 (+127) 
7E
01111110 (+126) 
01
00000001 (+1) 
00
00000000 (0) 
02
00000010 (+2) 
FF
11111111 (-1) 
FE
11111110 (-2) 
81
10000001 (-127) 
80
10000000 (-128) 
MIN
0
23
SCD-XA333ES
4-3. SACD (DL) DISC OPERATION CHECK
(• Perform as necessary)
The stability of the set can be checked by repeating the combined
operation of focus jump (layer 0
t1, layer 1t0) and access to
the most inward track
ymost outward track by the set number of
times or until an error occurs using the dual layer HD disc, DL
disc.
A set of operation including an access to the layer 0 (most inward
track)
tlayer 0 (most outward track)tfocus jump (layer
0
t1)tlayer 1 (most outward track)tlayer 1 (most inward
track)
tfocus jump (layer 1t0) is carried out repeatedly by the
set number of times.
Checking Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “92. SET CHECK” and press the 
[        AMS        ]
 dial
to enter.
2. When “SET TEST START” is displayed, rotate the
[        AMS        ]
 dial clockwise by 3 clicks to display “2.
F.JMP CHECK?”.
3. Press the 
[OPEN/CLOSE]
 button to open the tray, and place
the DL disc.
4. Press the 
[        AMS        ]
 dial to load the tray into the set.
5. “NOW SET UP” will be displayed and the DL disc setup will
start. (It takes about ten and several seconds to set up the disc
as two layers of layer 0 and layer 1 are adjusted)
6. At the completion of setup, “F.JUMP TIMES” will be dis-
played.
7. Rotate the 
[        AMS        ]
 dial clockwise by 5 clicks to display
“5”. (If 5 sets of operation is executed *1)
8. Press the 
[        AMS        ]
 dial, and the check will start.
9. Immediately when the check finished, “UP MAX
ssss”
t“UP AVE ssss”t“DW MAX
ssss”
t“DW AVE ssss”t“F.JMP OK 
[TIMES]
will be displayed repeatedly. (s denotes the measured value
in msec)
UP MAX: Max time required for layer 0 (most inward
track)
tlayer 0 (most outward track)tfocus jump
(layer 0
t1)
UP AVE:
Average time required for layer 0 (most inward
track)
tlayer 0 (most outward track)tfocus jump
(layer 0
t1)
DW MAX: Max time required for layer 1 (most outward
track)
tlayer 1 (most inward track)tfocus jump
(layer 1
t0)
DW AVE: Average time required for layer 1 (most outward
track)
tlayer 1 (most inward track)tfocus jump
(layer 1
t0)
Specified value: 7000 msec or less (if no error occurred)
If an error occurred due to defocusing during the checking,
refer to the following error list. (24 page)
10. Press the 
[OPEN/CLOSE]
 button, and the disc will be ejected
and the check will finish. Also, if the 
[        AMS        ]
 dial is
pressed in step 9, “2. F.JUMP CHK OK” will be displayed.
Then, if the 
[        AMS        ]
 dial is again pressed, “2. F.JMP
CHECK” will be displayed instantaneously and a recheck is
enabled from the step 5 in the same manner.
*1 Setting arbitrary number of times instead of 5 allows the check-
ing to be repeated by the set number of times. Also, setting 0
(zero) allows the aging check to be repeated until an error oc-
curs.
4-4. HYBRID DISC OPERATION CHECK
(• Perform as necessary)
This test checks the auto adjustment time required when the disc
is switched between HD (SACD) layer and CD layer. This test is
conducted to check the stability in switching from CD to SACD,
or SACD to CD in the HYBRID disc.
A set of operation including CD layer stop state
tHD layer auto
adjustment
tHD layer TOC readingtHD layer stop statetCD
layer auto adjustment
tCD layer TOC readingtCD layer stop
state is repeated by the set number of times.
Checking Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “92. SET CHECK” and press the 
[        AMS        ]
 dial
to enter.
2. When “SET TEST START” is displayed, rotate the
[        AMS        ]
 dial clockwise by 4 clicks to display “3.
HYB CHECK?”.
3. Press the 
[OPEN/CLOSE]
 button to open the tray, and place
the HYBRID disc.
4. Press the 
[        AMS        ]
 dial to load the tray into the set.
5. “NOW SET UP” will be displayed and the HYBRID disc setup
will start. (It takes about several seconds to set up the disc *1)
6. At the completion of setup, “CHANGE TIMES?” will be dis-
played.
7. Rotate the 
[        AMS        ]
 dial clockwise by 5 clicks to display
“5” (if 5 sets of operation is executed *2)
8. Press the 
[        AMS        ]
 dial, and “START” will be displayed
and the check will start. During the check, the following will
be displayed.
“CD—>HD” display: Time from switching from CD layer to
HD layer up to start of play is measured.
“HD—>CD” display: Time from switching from HD layer to
CD layer up to start of play is measured.
9. Immediately when the check finished, “CD MAX
ssss”
t“CD AVE ssss”t“HD MAX
ssss”
t“HD AVE ssss” will be displayed
repeatedly. (s denotes the measured value in msec)
Specified value: 10000 msec or less (if no error occurred)
If an error occurred due to defocusing during the checking,
refer to the following error list. (24 page)
10. Press the 
[OPEN/CLOSE]
 button, and the disc will be ejected
and the check will finish. Also, if the 
[        AMS        ]
 dial is
pressed in step 9, “HYB CHK OK” will be displayed. Then, if
the 
[        AMS        ]
 dial is again pressed, “HYBRID CHECK”
will be displayed instantaneously and a recheck is enabled from
the step 5 in the same manner.
*1 “NOW SET UP” display may continue for several minutes
and an error may be displayed depending on the discs. In this
case, press the 
[        AMS        ]
 dial again.
*2 Setting arbitrary number of times instead of 5 allows the check-
ing to be repeated by the set number of times. Also, setting 0
(zero) allows the aging check to be repeated until an error
occurs.
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
l
L
24
SCD-XA333ES
4-5 . AGING MODE
(• Perform as necessary)
4-5-1. The aging can be performed to the set in the test
mode
The aging can be continued by the set number of times or until an
error occurs.
In the aging, the following operations are repeated.
Table turn
tDisc chuckingtDisc detecttServo ontAuto
adjustment
tTOC readingtPlay of first track for 5 secondtPlay
of last track for 5 second
tPlay of first track for 5 secondtDisc
unchucking
Setting Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “94. SET AGING” and press the 
[        AMS        ]
 dial
to enter.
2. When “AGING TIMES” is displayed, rotate the 
[        AMS        ]
dial to set the number of aging times. (For the number of times,
every 10 times can be set. Setting 0 (zero) eliminates the count
limitation where the aging is repeated until an error occurs)
Note:
 Do not perform unmanned overnight aging..
3. Press the 
[        AMS        ]
 dial, and “AGING START” will be
displayed instantaneously, then “DISC IN & JOG ON” will be
displayed and the tray will come out automatically.
4. Place a disc (CD or the SACD SL disc) on the tray. In the case
of this set, the multiple discs can be placed. Even when the
discs (CD or the SACD SL disc) of different types are mixed,
the aging test can be performed. Use the 
[MULTI/2CH]
 key
when placing a disc. When discs are placed in positions, press
the 
[        AMS        ]
 dial.
5. The aging test starts.
6. At the completion of aging by the set number of times, the
tray will come out automatically and the check will stop.
Typical time required for aging    About 1 hour/100 times
“AGING SUCCESS!” will be displayed if no error occurred
in the aging, or the error will be displayed if an error occurred.
(Refer to the following error list)
4-6. SHIPPING MODE
The repaired set must be initialized, and for this purpose the set
should be set to the shipping mode.
Setting Method:
1. After setting the test mode, rotate the 
[        AMS        ]
 dial to
select “8d Set Up Init” and press the 
[        AMS        ]
 dial to
enter.
2. “8D 000000000 00” will be displayed, and if the scroll starts
in the left direction, the set initialization has completed
3. Press the 
[POWER]
 button to turn the power off.
Note:
Take care not to leave the test disc in the set.
The following setups are established in the SHIPPING MODE
Initialization of EEPROM (IC903)
• PLAY MODE
CONTINUE
• M/2CH SELECT
MULTI
• DIGITAL FILTER
STD
• 2ch SPK MODE
2ch DIRECT
• Mch SPK MODE
Mch DIRECT
• Resetting the accumulated hours meter.
l
L
l
L
l
L
l
L
l
L
l
L
l
L
Error List
An error occurring during the check in the aging mode of the test mode is displayed automatically (scroll display) immediately when the
error occurred.
< How to view the error history >
1. Select “95 DISP ERROR” with the 
[        AMS        ]
 key, and press the 
[        AMS        ]
 key once.
2. The error that has occurred lastly in the set and the signal status (H = 1, L = 0) at that time are displayed on the FL display by scrolling.
(Types of the errors and the signal status that can be checked, are the same as the error display of the aging mode.)
3. Press the 
[        AMS        ]
 key once again to show the error history repeatedly.
4. When the error history is displayed with scrolling once, the mode returns to the normal test mode.
l
L
l
L
l
L
Page of 96