DOWNLOAD Sony PMC-D407L Service Manual ↓ Size: 7.53 MB | Pages: 68 in PDF or view online for FREE

Model
PMC-D407L
Pages
68
Size
7.53 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
pmc-d407l.pdf
Date

Sony PMC-D407L Service Manual ▷ View online

– 9 –
3
 CNP504
4
 rear chassis (speaker) assy
1
 screw B tapping
2
 screw B tapping
3-8. REAR CHASSIS (SPEAKER) ASSY
3-9. POWER AMP, TERMINAL, JACK BOARD
5
 BVTP 3x10
3
 BVTP 3x10
4
 BVTP 3x10
1
 CNP503
2
 CNP505
9
 JACK board
8
 TERMINAL board
7
 POWER AMP board
6
 BTP 3x10
– 10 –
3-11. REAR CHASSIS (WOOFER SPEAKER) ASSY
3-10. POWER BOARD
1
 CNP501
4
 P 4x6
3
 P 4x6
2
 P 3x6
5
 POWER board
3
 CNP603
1
 screw +B tapping
2
 screw +B tapping
4
 CNP601
5
 rear chassis (woofer speaker) assy
– 11 –
3-12. S/WOOFER AMP BOARD
3-13. WOOFER POWER BOARD
5
 S/WOOFER AMP board
4
 BTP 3x10
3
 BVTP 3x10
2
 CNP602
1
 CNP605
3
 P 4x6
2
 P 4x6
1
 CNP606
4
 WOOFER POWER board
– 12 –
Tape Speed Adjustment
Procedure:
Mode: playback
32 
test tape
WS-48B
(3 kHz, 0 dB)
set
2
 (headphones) jack
digital frequency
counter
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 90 g
REV
CQ-403R
(more than 3.17 oz)
Mode
Torque Meter
Meter Reading
FWD
CQ-102C
30 – 70 g•cm
(0.42 – 1.02 oz•inch)
FWD
2.0 – 6.0 g•cm
Back tension
(0.028 – 0.076 oz•inch)
REV
CQ-102RC
30 – 70 g•cm
(0.42 – 1.02 oz•inch)
REV
2.0 – 6.0 g•cm
Back tension
(0.028 – 0.076 oz•inch)
80 – 170 g•cm
FF, REW
CQ-201B
(1.12 – 2.38 oz•inch)
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,970 and 3,030 Hz.
Adjustment Location:
SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback/erase head
pinch roller
rubber belts
capstan
idlers
2. Demagnetize the record/playback/erase head with a head de-
magnetizer. (Do not bring  the head demagnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Tape Tension  Measurement
Standard Output Level
Test Tape
  TAPE SECTION     0 dB = 0.775 V
1. The adjustments should be performed in the order given in the
service manual. (As a general rule. Playback circuit adjustment
should be completed before performing recording circuit ad-
justment.)
2. The adjustments should be performed for both L-ch and R-ch
unless otherwise indicated.
SP OUT
PHONES
Load impedance
6 Ω
32 Ω
Output  level
0.775 V (0 dB)
0.25 V (–10 dB)
Type
Signal
Used for
WS-48B
3 kHz, 0 dB
Tape speed adjustment
P-4-A063
6.3 kHz, –10 dB
Head azimuth adjustment
Digital frequency counter
2,970 to 3,030 Hz
adjustable 
resistor
M691
Adjust so that the value on the frequency counter is 3 kHz.
Specification Values:
Page of 68
Display

Click on the first or last page to see other PMC-D407L service manuals if exist.