– 29 –
Adjustment Location:
• PMC-D305
[TUNER  BOARD]
(Component Side)
[TUNER  BOARD]
(Component Side)
• PMC-D305L
IC1
CFT1
AM IF Adjustment
L1
CT1


FM Tracking
Adjustment
L3
CT2
AM Tracking
Adjustment
L2
FM Frequency
Coverage
Adjustment
L4
AM Frequency
Coverage
Adjustment
TU1
IC1
CFT1
AM IF Adjustment
CT5
L5
LW Tracking
Adjustment
CT4 L3
MW Tracking
Adjustment
L4
MW/LW Frequency
Coverage
Adjustment
– 30 –
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up is replaced.
Procedure:
1. Connect the oscilloscope to TP (TRACKING-Y) and TP (VC)
on the CD board.
2. Insert the disc (YEDS-18) in and close the lid for CD.
3. Put the set into test mode.
4. Press the 
+ and = buttons to move the optical pick-up to
the center.
5. Press the 
( button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
6. Adjust RV703 so that the oscilloscope traverse waveform is sym-
metrical, as shown in the figure below.
A
B
0 V
A
B
0 V
A=B
Note: Take long sweep time
for easy monitoring.
VOLT/DIV: 0.2 V (with the 10:1 probe in use.)
TIME/DIV: 1 ms
A=B
Adjustment value: 0.4 ± 0.2 Vp-p (A + B)
7. Release the test mode after adjustment is completed.
Adjustment Location: CD board (See page 33.)
+
CD board
TP (TRACKING-Y)
TP (VC)
Oscilloscope
(DC range)
TEST 1
Terminal
How to Release the Test Mode
1. Be sure to disconnect the AC plug cord and remove the solder
bridge at the TEST1 terminal connected before in setting.
2. The set thus becomes available for normal operation
Before Begining Adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
Press the 
+, = buttons and confirm that the optical pick-up
moves smoothly from the innermost to outermost circumference
and back smoothly and with no catching or abnormal noises.
+ : Optical pick-up moves to the outer circumference
= : Optical pick-up moves to the inner circumference
• Focus Search Check
1. Press the 
( button. (Focus search operation is performed con-
tinuously.)
2. Look at the optical pick-up objective lens and confirm that it
moves up and down smoothly, when no catching or abnormal
noises.
3. Press the 
p button.
Confirm that focus search operation stops. If it does not , press
the 
p button again longer.
Note: When the malfunction is occurred by mis-passing other keys, turn
off the power and check again from making the test mode.
Notes on Adjustment
1. Perform adjustment in test mode.
After adjustments, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when so
indicated.
How to Put the Set into Test Mode
1. Disconnect an AC plug cord. (Power is not applied to the set.)
2. Solder across the TEST1 terminal.
3. Close the lid for CD.
4. Connect an AC plug cord.
[SW  (A)  BOARD] (Conductor Side)
CD SECTION
– 31 –
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up is replaced.
Procedure:
1. Connect the oscilloscope TP (RF) and TP (VC) on the CD board.
2. Insert the disc (YEDS-18)  in and close the lid for CD.
3. Put the set into test mode. (See page 30.)
4. Press 
+ and = buttons to move the optical pick-up to the
center. (Move the optical pick-up to the music area on the disc
to enable easy visibility of the eye pattern.)
5. Press the 
( button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
6. Press the 
( button.
[Both tracking and sled are turned ON.]
7. Adjust RV701 so that the oscilloscope waveform is as shown in
the figure below. (eye pattern)
A good eye pattern means that the diamond shape (≈) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
VOLT/DIV : 0.2 V (With the 10:1 probe in use)
TIME/DIV  : 500 ns
1.3 
±
 0.2 Vp-p
+
CD board
TP (RF)
TP (VC)
Oscilloscope
(AC range)
When observing the eye pattern, set the oscilloscope for AC
range and raise vertical sensitivity.
8. Release the test mode after adjustment is completed.
Adjustment Location: CD board (See page 33.)
Gain
Focus
Tracking
Symptoms
• The time until music starts becomes
longer for 
p
( on automatic
selection.
low
low or high
(
=, + buttons pressed.)
(Normally takes about 2 seconds.)
• Music does not start and disc
low
continues to rotate for 
p
( or
automatic selection.
(
=, + buttons pressed.)
• Sound is interrupted during PLAY.
Or time counter display stops
low
progressing.
• More noise during 2-axis device
high
high
operation.
Focus/Tracking Gain Adjustment
A frequency responce analyzer is necessary in order to perform
this adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there
is no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock
when the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs
more easily.
• When gain adjustment is off, the symptoms below appear.
REFERENCE
– 32 –
The following is a simple adjustment method.
– Simple Adjustment –
Note: Since exact adjustment cannot be performed, remember the posi-
tions of the controls before performing the adjustment. If the posi-
tions after the primary adjustment are only a little different, return
the controls to the original position.
+
TP (FOCUS-Y)
TP (TRACKING-Y)
TP (VC)
oscillosope
(DC range)
CD board
Procedure:
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be performed
due to the gravity against the 2-axis device.
2. Connect the oscilloscope TP (FOCUS-Y) and TP (VC) on the
CD board.
3. Insert the disc (YEDS-18) in and close the lid for CD.
4. Put the set into test mode. (See page 30.)
5. Press the 
( button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
6. Press the 
( button.
[Both tracking and sled are turned ON.]
7. Adjust RV702 so that the waveform is as shown in the figure
below. (Focus gain adjustment)
100 mV
0 V
low focus gain
0 V
250 mV
high focus gain
VOLT/DIV: 100 mV
TIME/DIV:2ms
VOLT/DIV: 100 mV
TIME/DIV:2ms
VOLT/DIV: 100 mV
TIME/DIV:2ms
100 mV
75 mV
0 V
• Inconnect Examples (DC level changes more than on adjusted
waveform)
high tracking gain
high fandamental wave
than for low gain
VOLT/DIV: 1 V
TIME/DIV:2 ms
0 V
low tracking gain
VOLT/DIV: 1 V
TIME/DIV: 2ms
0 V
0 V
VOLT/DIV: 1 V
TIME/DIV: 2ms
8. Connect the oscilloscope to TP (TRACKING-Y) and TP (VC)
on the CD board.
9. Adjust RV704 so that the waveform is as shown in the figure
below. (tracking gain adjustment)
• Incorrect Examples (fundamental wave appears)
Note:
VOLT/DIV: with the 10:1 probe in used.
10. Release test mode after adjustment is completed.
Adjustment Location: CD board (See page 33.)
Page of 63