PMC-222V
— 37 —
— 38 —
— 39 —
— 40 —
— 41 —
5-5. SCHEMATIC DIAGRAM — CD, SYSTEM CONTROL SECTION —
• Waveform
Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted.  pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
¢
: internal component.
C
: panel designation.
U
: B+ Line.
H
: adjustment for repair.
• Voltages and waveforms are dc with respect to ground
under no-signal CD conditions.
no mark : CD
: Impossible to measure
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal production
tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production
tolerances.
• Circled numbers refer to waveforms.
• Signal path.
J
: CD
Note: The components identified by mark 
!
 or dotted line
with mark 
!
 are critical for safety.
Replace only with part number specified.
(Page  44)
M701
M702
(Page  57)
(Page  45)
E-F BALANCE
TRACKING
GAIN
FOCUS GAIN
PMC-222V
— 42 —
5-6. SCHEMATIC DIAGRAM — TUNER, TAPE, AMP SECTION —
• Waveform
Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted.  pF: µµF
50 WV or less are not indicated except for electrolytics and
tantalums.
• All resistors are in 
 and 
1
/
4
 
W or less unless otherwise
specified.
¢
: internal component.
C
: panel designation.
U
: B+ Line.
V
: B– Line.
H
: adjustment for repair.
• Voltages and waveforms are dc with respect to ground un-
der no-signal (detuned) conditions.
no mark : FM
(
) : AM
<<
>> : REC
[
] : PB
• Voltages are taken with a VOM (Input impedance 10 M
).
Voltage variations may be noted due to normal production
tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production
tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
E
: PB
a
: REC
J
: CD
Note: The components identified by mark 
!
 or dotted line
with mark 
!
 are critical for safety.
Replace only with part number specified.
(Page  37)
TO
(Page  57)
TO
J1003
(Page  40)
TO
CNP311
Q306
— 43 —
— 44 —
— 45 —
— 46 —