NW-HD5
7
3-4. CABINET (UPPER)  BLOCK  ASSY
1
two screws
(M1.4)
4
two screws
(M1.4)
2
screw (M1.4)
3
screw (M1.4) 
(EG)
S5009
5
cabinet (upper) 
block assy
knob (hold)
3-5. HDD  UNIT
4
Remove the HDD unit section 
in the direction of arrow.
5
insulator (L)
3
connector
(HDD board)
2
sheet (HDD FPC)
7
HDD unit
1
sheet (damper 1.5)
6
insulator (R)
NW-HD5
8
3-6. MAIN  BOARD  SECTION
3-7. MAIN  BOARD
3
claw
5
two screws 
(M1.4)
9
MAIN board
section
8
flexible board
(CN2001)
7
2
claw
4
bracket (battery) 
section
1
screw (M1.4)
6
sheet (HDD FPC)
2
two hooks
3
1
Remove two solders.
4
connector (CN5001)
6
MAIN board
5
LCD section
NW-HD5
9
3-8. POSITION  OF  FERRITE  CORE
40mm
40mm
50mm
A cable is rolled twice.
A cable is rolled twice.
A cable is rolled onece.
clamp filter (ferrite core) 
(Part No. 1-543-798-31)
clamp filter (ferrite core) 
(Part No. 1-543-798-31)
-AC ADAPTOR-
-USB CABLE-
10
NW-HD5
SECTION  4
TEST  MODE
1. OUTLINE
Power supply voltage : 3.65 to 3.75 V
Volume
: 27
SOUND EQ
: OFF
AVLS
: OFF
[HOLD] switch
: OFF
Set states
: horizontal states
2. SETTING  THE  TEST  MODE
1. Supply power to the set.
2. Switch-on the [HOLD] switch.
3. Operate as follows.
While pressing the [SEARCH/    MENU]
z
  key,  press the key as
following order.
[>] 
 [>] 
→ 
[<] 
→ 
[<] 
→ 
[>] 
→ 
[<] 
→ 
[>] 
→ 
[<] 
 
[E] 
 [
e]
4. Switch-off the [HOLD] switch and enter the test mode.
3. RELEASING  THE  TEST  MODE
Press the  
x
  key for 1.5 seconds or more, turn off the power and
release the test mode.
4. CONFIGURATION  OF  THE  TEST  MODE
Flow of the test mode:
5. OPERATION  OF  THE  TEST  MODE
5-1. Power
5-1-1. Power supply voltage check
This mode is used in case power supply voltage in the state where
all power supply lines (1.2 V/1.5 V/1.9 V/2.4 V/3.3 V/VSTBY) are
starting is checked.
Checking method:
1. Enter the test mode.
2. Press the
 
[>]
 
key to display major item, and press the [
E] [e]
key to select the “POWER”.
3. Press the
 
[>]
 
key to display minor item, and press the [
E] [e]
key to select the “V CHK”.
4. Press the 
u
 key, “START” is displayed and all power supply
lines are started.
In this state, the power supply voltage of each power supply line
can be confirmed by measuring the voltage of the following
points.
5. Press the [SEARCH/    MENU]
z
 key, “HD ON” or “HD OFF” is
displayed. In this state, each time [SEARCH/    MENU]
z
  key is
pressed, hard disk drive power supply ON/OFF switch is
performed.
6. Press the  
x
  key, return to minor item selection screen.
    V CHK
LCD display
    START
LCD display
    HD ON
LCD display
    POWER
LCD display
TP9001
(3.3V)
TP9005 (1.5V)
TP9007 (1.9V)
TP9004 (1.2V)
TP9015
(2.4V)
TP9014
(VSTBY)
– MAIN Board (Conductor Side) –
[<]
 key
[>]
 
key
[<]
 key
[>]
 
key
[     ]
 
key
F/W version display
Major item
Major item switching: 
[E]
 
[e]
 key
Minor item switching: 
[E]
 
[e]
 key
[  ]
 key
Minor item
Finish
or
Result
Start
Automatic
u
x
Page of 51