SECTION 4
ELECTRICAL ADJUSTMENTS
PRECAUTION
1. The adjustment should be performed in the publication.
(Be sure to male playback adjustment at first.)
2. The adjustments and measurement should be performed for
both L-CH and R-CH.
•
Switch position
DOLBY NR switch
DOLBY NR switch
: OFF
DIRECTION switch
:
A
•
Standard record position
Deliver the standard input signal level to input jack and set
the REC LEVEL (RV301) control to obtain the standard
output signal level as follows.
Deliver the standard input signal level to input jack and set
the REC LEVEL (RV301) control to obtain the standard
output signal level as follows.
– Record Mode –
set
AF OSC
attenuator
600
Ω
10 k
Ω
LINE IN
+
–
–
LINE OUT
47 k
Ω
level meter
Mode
Torque Meter
Meter Reading
CQ-102C
30-65 g•cm
FWD
(0.42-0.90 oz•inch)
FWD
1.5-6 g•cm
Back tension
(0.021-0.083 oz•inch)
CQ-102RC
30-65 g•cm
REV
(0.42-0.90 oz•inch)
REV
1.5-6 g•cm
Back tension
(0.021-0.083 oz•inch)
70-130 g•cm
FF, REW
CQ-201B
(0.98-1.80 oz•inch)
SECTION 3
MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback/earth head pinch roller
rubber belts
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head demagnetizer close to the erase
head.)
head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Standard Input Level
Input terminal
LINE IN
source impedance
10 k
Ω
input signal level
0.5 V (– 3.8 dB)
Standard Output Level
Output terminal
LINE OUT (L-CH)
load impedance
47 k
Ω
output signal level
0.5 V (– 3.8 dB)
Test Tape
Type
Signal
Used for
P-4-A100
10 kHz, – 10 dB
Azimuth Adjustment
P-4-L300
315 Hz,
0 dB
PB Level Adjustment
WS-48B
3 kHz,
0 dB
Tape Speed Adjustment
0 dB = 0.775 V
Test Mode
With the POWER turned OFF, short the test point CN801 (2P) on
the MAIN board (making IC801 pin &¢ “L”) and turn the POWER
ON. Thus, the TEST mode will be activated.
If a recording is done in the TEST mode, the REC MEMORY
mode becomes active where the tape is rewound by the amount of
recording when a rewinding is executed after recording.
After adjustment, make the CN801 (2P) open to release the TEST
mode.
the MAIN board (making IC801 pin &¢ “L”) and turn the POWER
ON. Thus, the TEST mode will be activated.
If a recording is done in the TEST mode, the REC MEMORY
mode becomes active where the tape is rewound by the amount of
recording when a rewinding is executed after recording.
After adjustment, make the CN801 (2P) open to release the TEST
mode.
– 11 –
Record/Playback Head Azimuth Adjustment
Procedure:
1. Mode: REV playback
1. Mode: REV playback
2. Turn the adjustment screw for the maximum output levels. If
these levels do not match, turn the adjustment screw until both
of output levels match together within 1 dB.
of output levels match together within 1 dB.
+
–
–
set
LINE OUT
frequency counter
test tape
WS-48B
(3 kHz, 0 dB)
WS-48B
(3 kHz, 0 dB)
47 k
Ω
1. Set to FWD playback mode.
2. Adjust Variable resistor on the motor (M902) so that the fre-
2. Adjust Variable resistor on the motor (M902) so that the fre-
quency counter reading becomes
3,000 ± 90 Hz.
3. Confirm that the deviation between tape top and tape end is
within 3%.
Adjustment Location: CAPSTAN/REEL motor (M902)
Screw
position
position
L-CH
peak
peak
within
1dB
1dB
output
level
level
L-CH peak
R-CH peak
within
1dB
1dB
angle
R-CH
peak
peak
3. Phase Check
Mode: REV playback
+
–
–
V
H
+
–
Screen pattern
Good
Wrong
in phase 45
°
90
°
135
°
180
°
LINE OUT
set
R-CH
L-CH
47 k
Ω
47 k
Ω
oscilloscope
test tape
P-4-A100
(10 kHz, –10 dB)
P-4-A100
(10 kHz, –10 dB)
4. Set in the FWD mode and repeat the step 1 to 3.
5. After the adjustment, lock the screw with locking compound.
5. After the adjustment, lock the screw with locking compound.
Adjustment Location: Record/Playback head
FWD side
REV side
Adjustment screw
+
–
–
set
47 k
Ω
LINE OUT
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
P-4-A100
(10 kHz, – 10 dB)
Tape Speed Adjustment
Procedure:
Mode: FWD playback
Mode: FWD playback
M902
adjustable resistor
Sample Value of Wow and flutter: 0.3% or less W. RMS
(WS-48B)
– 12 –
Record Level Adjustment
Setting:
REC LEVEL control: Standard record position (See page 10)
set to the TEST mode (REC MEMRY mode) (See page 10)
REC LEVEL control: Standard record position (See page 10)
set to the TEST mode (REC MEMRY mode) (See page 10)
Procedure:
1. Mode :Record
1. Mode :Record
+
–
–
set
LINE OUT
47 k
Ω
test tape
P-4-L300
(315 Hz, 0 dB)
P-4-L300
(315 Hz, 0 dB)
level meter
Adjust RV151 (L-CH) and RV251 (R-CH) so that the reading on
level meter meets the adjustment limits below.
level meter meets the adjustment limits below.
Adjustment Limits:
LINE OUT level: – 7.7 ± 0.5 dB (0.301 to 0.338 V)
Level difference between channels: within 2 dB
Level difference between channels: within 2 dB
Check that the LINE OUT level does not change even if Playback
and Stop operation is repeated several times.
and Stop operation is repeated several times.
Adjustment Location: MAIN board (See page 13)
Playback Level Adjustment
Procedure:
Mode: FWD playback
Mode: FWD playback
Record BIAS Adjustment
Setting:
REC LEVEL control: Standard record position (See page 10)
Set to the TEST mode (REC MEMRY mode) (See page 10)
Procedure:
1. Mode: Record
REC LEVEL control: Standard record position (See page 10)
Set to the TEST mode (REC MEMRY mode) (See page 10)
Procedure:
1. Mode: Record
set
AF OSC
attenuator
600
Ω
10 k
Ω
blank tape
CS-123
CS-123
LINE IN
1) 315 Hz
2) 10 kHz
1) 315 Hz
2) 10 kHz
50 mV (– 23.8 dB)
2. Mode: Playback
+
–
–
set
LINE OUT
47 k
Ω
recorded portion
level meter
3. Confirm playback the signal recorded in step 1 become ad-
justment level as follows.
4. If these levels do not adjustment level, adjust the RV152 (L-
CH) and RV252 (R-CH) to repeat step 1 and 2.
Adjustment Level:
Playback output of 10 kHz to playback
output of 315 Hz: ± 0.5 dB.
output of 315 Hz: ± 0.5 dB.
Adjustment Location: MAIN board (See page 13)
set
AF OSC
attenuator
600
Ω
10 k
Ω
blank tape
CS-123
CS-123
LINE IN
315 Hz, 50 mV (– 23.8 dB)
315 Hz, 50 mV (– 23.8 dB)
2. Mode: Playback
+
–
–
set
LINE OUT
47 k
Ω
recorded portion
level meter
3. Confirm playback the signal recorded in step 1 become ad-
justment level as follows.
4. If these levels do not adjustment level, adjust RV153 (L-CH)
and RV253 (R-CH) to repeat step 1 and 2.
Adjustment Level:
– 23.8 ± 0.5 dB (47 to 53 mV)
Adjustment Location: MAIN board (See page 13)