5-1. PARTS REPLACEMENT AND ADJUSTMENT
• Check and adjust the MDM and MBU as follows.
The procedure changes according to the part replaced
SECTION 5
ELECTRICAL ADJUSTMENTS
• Abbreviation
OP
: Optical pick-up
OWH: Overwrite head
• Temperature compensation offset check
• Laser power check
• Traverse check
• Focus bias check
• C PLAY check
• Self-recording/playback check
• Laser power check
• Traverse check
• Focus bias check
• C PLAY check
• Self-recording/playback check
Parts Replacement and Repair
NG
Has the OWH been replaced?
NO
OK
NO
NO
NO
Has OP, IC171, IC101, or
IC121 been replaced?
IC121 been replaced?
YES
YES
Initial setting of the adjustment value
Has OP or IC171 been replaced?
YES
IOP information recording
(IOP value labeled on OP)
(IOP value labeled on OP)
Has IC171 or D101
been replaced?
been replaced?
YES
Temperature compensation offset adjustment
• Laser power adjustment
• Traverse adjustment
• Focus bias adjustment
• Error rate adjustment
• Focus bias check
• Auto gain adjustment
• Traverse adjustment
• Focus bias adjustment
• Error rate adjustment
• Focus bias check
• Auto gain adjustment
Check the sleding and spindle
mechanisms.
Other causes can be suspected.
mechanisms.
Other causes can be suspected.
– 42 –
5-2. PRECAUTIONS FOR CHECKING LASER DIODE
EMISSINON
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
view directly from the top as this may lose your eye-sight.
5-3. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take
adequate measures to prevent damage by static electricity. Handle
the flexible board with care as it breaks easily.
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connect-
ing the connector, be careful not to remove the solder. Also take
adequate measures to prevent damage by static electricity. Handle
the flexible board with care as it breaks easily.
Optical pick-up flexible board
5-4. PRECAUTIONS FOR ADJUSTMENTS
Optical
Pick-up
BD Board
IC101, IC121
D101
IC171
¬
G
¬
¬
pick-up
flexible board
laser tap
1. Initial setting of
adjustment value
2. Recording of IOP
information
(Value written in
the pick-up)
3. Temperature
compensation
offset adjustment
offset adjustment
4. Laser power
adjustment
5. Traverse
adjustment
6. Focus bias
adjustment
7. Error rate check
8. Auto gain output
level adjustment
IC192
G
¬
G
¬
G
G
¬
¬
G
G
G
¬
G
¬
¬
¬
¬
G
¬
¬
G
¬
G
¬
¬
G
¬
G
¬
¬
G
¬
G
¬
¬
G
2) Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
Perform the adjustments and checks in “group S” of the test mode.
Perform the adjustments and checks in “group S” of the test mode.
3) Perform the adjustments to be needed in the order shown.
4) Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
• TEST DISK (MDW-74/AU-1) (Parts No. 8-892-341-41)
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
or
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
or
MD Laser power meter 8010S (Parts No. J-2501-145-A) (Note)
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Parts No. : J-2501-149-A)
5) When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the oscillo-
scope.
(VC and ground will become short-circuited.)
scope.
(VC and ground will become short-circuited.)
6) Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Note on page 6.)
(Refer to Servicing Note on page 6.)
7) As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
Note : When performing laser power checks and adjustment
(electrical adjustment), use of the new MD laser power meter
8010S (J-2501-145-A) instead of the conventional laser
power meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of the pick-up.
8010S (J-2501-145-A) instead of the conventional laser
power meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of the pick-up.
5-5. CREATING CONTINUOUSLY RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording disc.
1. Insert a disc (blank disc) commercially available.
2. Rotate the AMS knob and display “CREC MODE”. (S: 31)
3. Press the YES button again to display “CREC MID”.
2. Rotate the AMS knob and display “CREC MODE”. (S: 31)
3. Press the YES button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the MENU/NO button and stop recording .
6. Press the §EJECT button and remove the disc.
5. Press the MENU/NO button and stop recording .
6. Press the §EJECT button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
This unit uses two mechanism (Deck A) and (Deck B).
The decks can be operated individually.
For buttons or knobs not specified as Deck A or Deck B in the
procedure, use that of the corresponding deck.
The decks can be operated individually.
For buttons or knobs not specified as Deck A or Deck B in the
procedure, use that of the corresponding deck.
1) When replacing the following parts, perform the adjustments
and checks with ¬ in the order shown in the following table.
– 43 –
5-6. CHECKS PRIOR TO REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and
Adjustments” (See page 8).
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and
Adjustments” (See page 8).
5-6-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and room
temperature to 22 to 28 C.
temperature to 22 to 28 C.
Checking Procedure:
1. Rotate the AMS knob to display “TEMP CHECK”.
2. Press the YES button.
3. “T=@@(##) (OK” should be displayed. If “T=@@ (##) (NG”
1. Rotate the AMS knob to display “TEMP CHECK”.
2. Press the YES button.
3. “T=@@(##) (OK” should be displayed. If “T=@@ (##) (NG”
is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
5-6-2. Laser Power Check
Before checking, check the IOP value of the optical pick-up.
(Refer to 5-8. Recording and Displaying IOP Information.)
(Refer to 5-8. Recording and Displaying IOP Information.)
Connection :
KMS
260A
27X40
B0825
B0825
N
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
Iop (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
Checking Procedure:
1. Set the laser power meter on the objective lens of the optical
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the 0 button
or ) button to move the optical pick-up.)
Connect the digital volt meter to CN110 pin
or ) button to move the optical pick-up.)
Connect the digital volt meter to CN110 pin
5 (I+3V) and
CN110 pin
4 (IOP).
2. Then, rotate the AMS knob and display “LDPWR CHECK”
(S: 2).
3. Press the YES button once and display “LD 0.9 mW $
”.
Check that the reading of the laser power meter become 0.84 to
0.92 mW.
0.92 mW.
4. Press the YES button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Specified Value :
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
5. Press the MENU/NO button and display “LDPWR CHECK”
and stop the laser emission.
(The MENU/NO button is effective at all times to stop the
laser emission.)
(The MENU/NO button is effective at all times to stop the
laser emission.)
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying IOP Information”.)
this value, refer to “5-8. Recording and
Displaying IOP Information”.)
5-6-3. Traverse Check
Connection :
Checking Procedure:
1. Connect an oscilloscope to CN110 pin
1. Connect an oscilloscope to CN110 pin
3 (TEO) and CN110
pin
1 (VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1.)
3. Press the ) button and move the optical pick-up outside the
3. Press the ) button and move the optical pick-up outside the
pit.
4. Rotate the AMS knob and display “EF MO CHECK”(S: 3).
5. Press the YES button and display “EFB =
5. Press the YES button and display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
spindle (S) servo ON)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Read power traverse checking)
(Read power traverse checking)
(Traverse Waveform)
7. Press the YES button and display “EFB =
MO-W”.
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Write power traverse checking)
(Write power traverse checking)
(Traverse Waveform)
9. Press the YES button display “EFB =
MO-P”.
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
and servo is imposed.
Note 1: After step 4, each time the YES button is pressed, the
display will be switched between “LD 0.7 mW $
”, “LD
6.2 mW $
”, and “LD Wp $
”. Nothing needs
to be performed here.
Laser power
meter
meter
Optical pick-up
objective lens
objective lens
Digital volt meter
BD board
CN110 pin
5
(I+3V)
CN110 pin
4
(IOP)
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
I
A – BI
2 (A + B)
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
H : 10 ms/div
Input : DC mode
Oscilloscope
BD board
CN110 pin
3
(TEO)
CN110 pin
1
(VC)
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
I
A – BI
2 (A + B)
– 44 –
10. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Traverse Waveform)
11. Press the YES button display “EF MO CHECK”
The disc stops rotating automatically.
12. Press the §EJECT button and remove the disc.
13. Load the check disc (MD) TDYS-1.
14. Roteto the AMS knob and display “EF CD CHECK” (S: 4).
15. Press the YES button and display “EFB =
13. Load the check disc (MD) TDYS-1.
14. Roteto the AMS knob and display “EF CD CHECK” (S: 4).
15. Press the YES button and display “EFB =
CD”. Servo is
imposed automatically.
16. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not rotate the AMS knob.
(Traverse Waveform)
17. Press the YES button and display “EF CD CHECK”.
18. Press the §EJECT button and remove the check disc (MD)
18. Press the §EJECT button and remove the check disc (MD)
TDYS-1.
Note 1 : MO reading data will be erased during if a recorded disc is
used in this adjustment.
Note 2 : If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
seen more clearly.
5-6-4. Focus Bias Check
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a test disk (MDW-74/AU-1).
2. Rotate the AMS knob and display “CPLAY MODE” (S: 30).
3. Press the YES button twice and display “CPLAY MID”.
4. Press the MENU/NO button when “C =
Checking Procedure :
1. Load a test disk (MDW-74/AU-1).
2. Rotate the AMS knob and display “CPLAY MODE” (S: 30).
3. Press the YES button twice and display “CPLAY MID”.
4. Press the MENU/NO button when “C =
AD =
” is
displayed.
5. Rotate the AMS knob and display “FBIAS CHECK” (S: 5).
6. Press the YES button and display “
6. Press the YES button and display “
/
c =
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 220 and ADER is below 2.
after [/] indicate ADER, and the 2 digits after [c =] indicate the
focus bias value.
Check that the C1 error is below 220 and ADER is below 2.
7. Press the YES button and display “
/
b =
”.
Check that the C1 error is below 220 and ADER is below 2.
8. Press the YES button and display “
/
a =
”.
Check that the C1 error is below 220 and ADER is below 2.
9. Press the MENU/NO button, next press the §EJECT button,
and remove the test disc.
5-6-5. C PLAY Checking
MO Error Rate Check
Checking Procedure :
1. Load a test disk (MDW-74/AU-1).
2. Rotate the AMS knob and display “CPLAY MODE” (S: 30).
3. Press the YES button and display “CPLAY MID”.
4. The display changes to “C =
1. Load a test disk (MDW-74/AU-1).
2. Rotate the AMS knob and display “CPLAY MODE” (S: 30).
3. Press the YES button and display “CPLAY MID”.
4. The display changes to “C =
AD =
”.
5. If the C1 error rate is below 80, check that ADER is below 2.
6. Press the MENU/NO button, stop playback, press the §EJECT
6. Press the MENU/NO button, stop playback, press the §EJECT
button, and test disc.
CD Error Rate Check
Checking Procedure :
1. Load a check disc (MD) TDYS-1.
2. Rotate the AMS knob and display “CPLAY MODE” (S: 30).
3. Press the YES button twice and display “CPLAY MID”.
4. The display changes to “C =
1. Load a check disc (MD) TDYS-1.
2. Rotate the AMS knob and display “CPLAY MODE” (S: 30).
3. Press the YES button twice and display “CPLAY MID”.
4. The display changes to “C =
AD =
”.
5. Check that the C1 error rate is below 50.
6. Press the MENU/NO button, stop playback, press the §EJECT
6. Press the MENU/NO button, stop playback, press the §EJECT
button, and the test disc.
5-6-6. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
and check the error rate.
Checking Procedure :
1. Insert a recordable disc (blank disc) into the unit.
2. Rotate the AMS knob to display “CREC MODE” (S: 31).
3. Press the YES button to display the “CREC MID”.
4. When recording starts, “
1. Insert a recordable disc (blank disc) into the unit.
2. Rotate the AMS knob to display “CREC MODE” (S: 31).
3. Press the YES button to display the “CREC MID”.
4. When recording starts, “
REC
” is displayed, this becomes
“CREC @@@@" (@@@@ is the address), and recording starts.
5. About 1 minute later, press the MENU/NO button to stop
continuous recording.
6. Rotate the AMS knob to display “C PLAY MODE” (S: 30).
7. Press the YES button to display “C PLAY MID”.
8. “C =
7. Press the YES button to display “C PLAY MID”.
8. “C =
AD =
” will be displayed.
9. Check that the C1 error becomes below 80 and the AD error
below 2.
10. Press the MENU/NO button to stop playback, and press the
§EJECT button and remove the disc.
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
I
A – BI
2 (A + B)
VC
A
B
Specified value : Below 10% offset value
Offset value (%) = X 100
I
A – BI
2 (A + B)
330 k
Ω
Oscilloscope
10pF
BD board
CN110 pin
3
(TEO)
CN110 pin
1
(VC)