– 25 –
7. INITIAL  SETTING  OF  ADJUSTMENT  VALUE
Note:
Mode which sets the adjustment results recorded in the non-volatile
memory to the initial setting value. However the results of the tempera-
ture compensation offset adjustment will not change to the initial setting
value.
If initial setting is performed, perform all adjustments again excluding the
temperature compensation offset adjustment.
For details of the initial setting, refer to “4. Precautions on Adjustments”
and execute the initial setting before the adjustment as required.
Setting Procedure :
1. Turn the
AMS
 
+ knob to display “ADJ CLEAR (C24)”.
2. Press the 
[YES]
 button. “Complete!” will be displayed mo-
mentarily and initial setting will be executed, after which “ADJ
CLEAR” will be displayed.
8. RECORDING  AND  DISPLAYING  THE  IOP
INFORMATION
The IOP data can be recorded in the non-volatile memory. The
IOP value on the label of the optical pickup and the IOP value
after the adjustment will be recorded. Recording these data elimi-
nates the need to read the label on the optical pick-up.
Recording Procedure :
1. Turn the
AMS
 
+ knob to display “Iop Write” (C28),
and press the 
[YES]
 button.
2. The display becomes Ref=@@@.@ (@ is an arbitrary num-
ber) and the numbers which can be changed will blink.
3. Input the IOP value written on the optical pick-up.
To select the number : Turn the
AMS
 
+ knob.
To select the digit : Press the
AMS
 
+ knob
4. When the 
[YES]
 button is pressed, the display becomes
“Measu=@@@.@” (@ is an arbitrary number).
5. As the adjustment results are recorded for the 6 value. Leave it
as it is and press the 
[YES]
 button.
6. “Complete!” will be displayed momentarily. The value will be
recorded in the non-volatile memory and the display will be-
come “Iop Write”.
Display Procedure :
1. Turn the
AMS
 
+ knob to display “Iop Read”(C27).
2. “@@.@/##.#” is displayed and the recorded contents are dis-
played.
@@.@ indicates the IOP value labeled on the pick-up.
##.# indicates the IOP value after adjustment
3. To end, press the
AMS
 
+ button or 
[MENU/NO]
 but-
ton to display “Iop Read”.
9. TEMPERATURE  COMPENSATION  OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28 ˚C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22 ˚C
to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
Adjusting Procedure :
1. Turn the  
AMS
 
+ knob and display “TEMP ADJUST”
(C09).
2. Press the  
[YES]
 button and select the “TEMP ADJUST” mode.
3. “TEMP = 
 [OK” and the current temperature data will be
displayed.
4. To save the data, press the 
[YES]
 button.
When not saving the data, press the 
[MENU/NO]
 button.
5. When the 
[YES]
 button is pressed, “TEMP = 
 SAVE” will
be displayed and turned back to “TEMP ADJUST” display
then. When the 
[MENU/NO]
 button is pressed, “TEMP AD-
JUST” will be displayed immediately.
Specified Value :
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,  “10 - 1F” and “20 - 2F”.
10. LASER POWER ADJUSTMENT
Check the IOP value of the optical pick-up before adjustments.
(Refer to 8. Recording and Displaying IOP Information)
Connection :
Adjusting Procedure :
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
0 button
or
) button to move the optical pick-up.)
Connect the digital volt meter to CN110 pin 5 (I+3V) and
CN110 pin 4 (IOP).
2. Turn the
AMS
 
+ knob and display “LDPWR AD-
JUST” (C10).
(Laser power : For adjustment)
3. Press the 
[YES]
 button once and display “LD 0.9 mW $ 
”.
4. Turn the
AMS
 
+ knob so that the reading of the laser
power meter becomes 0.85 to 0.91 mW. Press the 
[YES]
   but-
ton after setting the range knob of the laser power meter, and
save the adjustment results. (“LD SAVE $ 
” will be dis-
played for a moment.)
5. Then “LD 7.0 mW $ 
” will be displayed.
6. Turn the
AMS
 
+ knob so that the reading of the laser
power meter becomes 6.9 to 7.1 mW, press the 
[YES]
 button
and save it.
Note:
Do not perform the emission with 7.0 mW more than 15 seconds
continuously.
Optical pick-up
objective lens
laser
power meter
+
BD board
digital voltmeter
CN110 pin 
5
 (I +3V)
CN110 pin 
4
 (IOP)
[      ]
[      ]
– 26 –
7. Then, turn the
AMS
 
+ knob and display “LDPWR
CHECK” (C02).
8. Press the 
[YES]
 button once and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter become 0.85
to 0.91 mW.
9. Press the  
[YES]
 button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specification:
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value
±10%
10. Press the 
[MENU/NO]
 button and display “LDPWR CHECK”
and stop the laser emission.
(The 
[MENU/NO]
 button is effective at all times to stop the
laser emission.)
11. Turn the
AMS
 
+ knob to display “Iop Write”(C28).
12. Press the
[YES]
 button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the 
[YES]
button to display “Measu=@@@.@” (@ is an arbitrary num-
ber).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Turn the
AMS
 
+ knob.
To select the digit : Press the
AMS
 
+ knob.
14. When the 
[YES]
 button is pressed, “Complete!” will be dis-
played momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write”.
Note 1:
After step 4, each time the
 [YES] 
button is pressed, the display
will be switched between “LD 0.7 mW $ 
”, “LD 6.2 mW $
”, and “LD Wp                 $ 
”. Nothing needs to be performed
here.
KMS260A
27X40
B0825
lOP=82.5 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
)
(Optical pick-up label)
11. TRAVERSE ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN110 pin 3 (TEO) and CN110
pin 1 (VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the
) button and move the optical pick-up outside
the pit.
4. Turn the
AMS
 
+ knob and display “EF MO ADJUST”
(C10).
5. Press the 
[YES]
 button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo
OFF/spindle (S) servo ON)
6. Turn the
AMS
 
+ knob so that the waveform of the
oscilloscope becomes the specified value.
(When the
AMS
 
+ knob is turned, the   of “EFB=
” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as pos-
sible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the  
[YES]
  button and save the result of adjustment to
the non-volatile memory (“EFB = 
 SAV” will be displayed
for a moment. Then “EFB = 
 MO-W” will be displayed).
+
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN110 pin 
3
 (TEO)
CN110 pin 
1
 (VC)
[      ]
+
oscilloscope
(DC range)
10 pF
330 k 
CN110 pin 
3
 (TEO)
CN110 pin 
1
 (VC)
BD board
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
A
B
VC
Specification A = B
– 27 –
8. Turn the
AMS
 
+ knob so that the waveform of the
oscilloscope becomes the specified value.
(When the
AMS
 
+ knob is turned, the   of “EFB-
” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as pos-
sible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the 
[YES]
 button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAV” will be displayed for
a moment.)
10. “EFB = 
 MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and
servo is imposed.
11. Turn the  
AMS
 
+ knob until the waveform of the os-
cilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
12. Press the  
[YES]
 button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAV” will be displayed for
a moment.)
Next “EF MO ADJUST” is displayed. The disc stops rotating
automatically.
13. Press the 
[     EJECT]
 button and take out the disc.
14. Load the check disc (MD) TDYS-1.
15. Turn the
AMS
 
+ knob and display “EF CD ADJUST”
(C12).
16. Press the 
[YES]
 button and display “EFB = 
 CD”. Servo is
imposed automatically.
17. Turn the
AMS
 
+ knob so that the waveform of the
oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
§
18. Press the 
[YES]
 button, display “EFB = 
 SAV” for a mo-
ment and save the adjustment results in the non-volatile
memory.
Next “EF CD ADJUST” will be displayed.
19. Press the 
[     EJECT]
 button and take out the disc.
12. FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1. Load the continuously-recorded disc.  (Refer to “5.  CREAT-
ING CONTINUOUSLY-RECORDED DISC”)
2. Turn the
AMS
 
+ knob and display “CPLAY MODE”
(C29).
3. Press the 
[YES]
 button and display “CPLAY MID”.
4. Press the 
[MENU/NO]
 button when “C1 = 
 AD = 
” is
displayed.
5. Turn the
AMS
 
+ knob and display “FBIAS ADJUST”
(C13).
6. Press the 
[YES]
 button and display “
/
 a = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [a =] indicate
the focus bias value.
7. Turn the
AMS
 
+ knob in the clockwise direction and
find the focus bias value at which the C1 error rate becomes
about 200 (Refer to Note 2).
8. Press the 
[YES]
 button and display “
/
 b = 
”.
9. Turn the  
AMS
 
+ knob in the counterclockwise di-
rection and find the focus bias value at which the C1 error rate
becomes about 200.
10. Press the 
[YES]
 button and display “
/
 c = 
”.
11. Check that the C1 error rate is below 50 and ADER is 00.
Then press the 
[YES]
 button.
12. If the “(
)” in “
 - 
 - 
 (
)” is above 20, press the 
[YES]
button.
If below 20, press the 
[MENU/NO]
 button and repeat the ad-
justment from step 2.
13. Press the 
[     EJECT]
 button and take out the disc.
Note 1:
The relation between the C1 error and focus bias is as shown in
the following figure. Find points A and B in the following figure
using the above adjustment. The focal point position C is auto-
matically calculated from points A and B.
Note 2:
As the C1 error rate changes, perform the adjustment using the
average vale.
§
C1 error
about 
200
B
C
A
Focus bias value
(F. BIAS)
A
B
VC
Specification A = B
A
B
VC
Specification A = B
§
A
B
VC
Specification A = B
– 28 –
13. ERROR  RATE  CHECK
13-1. CD Error Rate Check
Checking Procedure :
1. Load the check disc (MD) TDYS-1.
2. Turn the
AMS
 
+ knob and display “CPLAY MODE”
(C30).
3. Press the
 [YES] 
button twice and display “CPLAY MID”.
4. The display changes to “C1 = 
 AD = 
”.
5. Check that the C1 error rate is below 20.
6. Press the
  [MENU/NO]
 button, stop playback, press the
[     EJECT]
 button and take out the check disc.
13-2. MO Error Rate Check
Checking Procedure :
1. Load the test disc (MDW-74/AU-1).
2. Turn the
AMS
 
+ knob and display “CPLAY MODE”
(C30).
3. Press the
 [YES] 
button and display “CPLAY MID”.
4. The display changes to “C1 = 
 AD = 
”.
5. If the C1 error rate is below 50, check that ADER is 00.
6. Press the
[MENU/NO]
 button, stop playback, press the
[     EJECT]
   button and take out the test disc.
14. FOCUS  BIAS  CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load the continuously-recorded disc.  (Refer to “5.  CREAT-
ING CONTINUOUSLY-RECORDED DISC”)
2. Turn the
AMS
 
+ knob and display “CPLAY MODE”
(C30).
3. Press the 
[YES]
 button twice and display “CPLAY MID”.
4. Press the 
[MENU/NO]
 button when “C1 = 
 AD = 
” is
displayed.
5. Turn the
AMS
 
+ knob and display “FBIAS CHECK”
(C05).
6. Press the 
[YES]
 button and display “
/
 c = 
”.
The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate
the focus bias value.
Check that the C1 error is below 50 and ADER is below 2.
7. Press the 
[YES]
 button and display “
/
 b = 
”.
Check that the C1 error is about 200 and ADER is below 2.
8. Press the 
[YES]
 button and display “
/
 a = 
”.
Check that the C1 error is about 200 and ADER is below 2
9. Press the 
[MENU/NO]
 button, next press the 
[     EJECT]
 but-
ton and take out the disc.
Note 1:
If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the above),
the focus bias adjustment may not have been carried out prop-
erly. Adjust perform the beginning again.
§
§
§
15. AUTO  GAIN  CONTROL  OUTPUT  LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the pickup is replaced.
If the adjustment results becomes “Adjust NG!”, the pickup may
be faulty or the servo system circuits may be abnormal.
15-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the check disc (MD) TDYS-1.
2. Turn the
AMS
 
+ knob to display “AG Set (CD)” (C26).
3. When the 
[YES]
 button is pressed, the adjustment will be per-
formed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (CD)”.
4. Press the 
[     EJECT]
 button and take out the check disc.
15-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the test disc (MDW-74/AU-1) for recording.
2. Turn the
AMS
 
+ knob to display “AG Set (MO)” (C25).
3. When the 
[YES]
 button is pressed, the adjustment will be per-
formed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (MO)”.
4. Press the 
[     EJECT]
 button and take out the test disc.
§
§