5-7. INITIAL SETTING OF ADJUSTMENT VALUE
Note:
Mode which sets the adjustment results recorded in the non-vola-
tile memory to the initial setting value. However the results of the
temperature compensation offset adjustment will not change to the
initial setting value.
If initial setting is performed, perform all adjustments again ex-
cluding the temperature compensation offset adjustment.
For details of the initial setting, refer to “5-4. Precautions on Ad-
justments” and execute the initial setting before the adjustment as
required.
Setting Procedure :
1. Rotate the  l AMS L  knob to display “ADJCLEAR”
(C28).
2. Press the  YES  button. “Complete!” will be displayed momen-
tarily and initial setting will be executed, after which “ADJ
CLEAR”(C28) will be displayed.
5-8. RECORDING AND DISPLAYING THE Iop
INFORMATION
The IOP data can be recorded in the non-volatile memory. The Iop
value on the label of the optical pick-up and the Iop value after the
adjustment will be recorded. Recording these data eliminates the
need to read the label on the optical pick-up.
Recording Procedure :
1. While pressing the  l AMS L  knob and  x  button, con-
nect the power plug to the outlet, and release the  l AMS
L  knob and  x  button.
2. Rotate the  l AMS L  knob to display “[Service]”, and
press the  YES  button.
3. Rotate the  l AMS L  knob to display “Iop.Write”(C05),
and press the  YES  button.
4. The display becomes Ref=@@@.@ (@ is an arbitrary number)
and the numbers which can be changed will blink.
5. Input the Iop value written on the optical pick-up.
To select the number : Rotate the  l AMS L  knob.
To select the digit : Press the  l AMS L  knob
6. When the  YES  button is pressed, the display becomes
“Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave it
as it is and press the  YES  button.
8. “Complete!” will be displayed momentarily. The value will be
recorded in the non-volatile memory and the display will be-
come “Iop Write”(C05).
Display Procedure :
1. Rotate the  l AMS L  knob to display “Iop.Read”(C26)
and press the  YES  button.
2. “@@.@/##.#” is displayed and the recorded contents are
displayed.
@@.@ indicates the Iop value labeled on the pick-up.
##.# indicates the Iop value after adjustment
3. To end, press the  l AMS L  button or  MENU/NO
button to display “Iop Read”(C26).
5-9. TEMPERATURE COMPENSATION OFFSET
ADJUTMENT
Save the temperature data at that time in the non-volatile memory
as 25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to
28 ˚C. Perform it immediately after the power is turned on when
the internal temperature of the unit is the same as the ambient
temperature of 22 ˚C to 28 ˚C.
3. When D101 has been replaced, perform this adjustment after
the temperature of this part has become the ambient tempera-
ture.
Adjusting Procedure :
1. Rotate the  l AMS L  knob and display “TEMP ADJUS”
(C03).
2. Press the  YES  button and select the “TEMP ADJUS”(C03)
mode.
3. “TEMP = 
[OK]” and the current temperature data will be
displayed.
4. To save the data, press the  YES  button.
When not saving the data, press the  MENU/NO  button.
5. When the  YES  button is pressed, “TEMP = 
 SAVE” will be
displayed and turned back to “TEMP ADJUS”(C03) display then.
When the  MENU/NO  button is pressed, “TEMP ADJUS” (C03)
will be displayed immediatelly.
Specified Value :
The “TEMP =  
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,  “10 - 1F” and “20 - 2F”.
5-10. LASER POWER ADJUSTMENT
Check the Iop value of the optical pick-up before adjustments.
(Refer to 5-8. Recording and Displaying Iop Information.)
Connection :
Adjusting Procedure :
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the  m  button
or  M  button to move the optical pick-up.)
Connect the digital volt meter to CN105 pin 1 (I+3V) and
CN105 pin 2 (IOP).
2. Rotate the  l AMS L  knob and display “LDPWR
ADJUST”(C04).
(Laser power : For adjustment)
3. Press the  YES  button once and display “LD 0.9 mW $ 
”.
4. Rotate the  l AMS L  knob so that the reading of the laser
power meter becomes the specified value. Press the  YES
button after setting the range knob of the laser power meter, and
save the adjustment results. (“LD SAVE $ 
” will be displayed
for a moment.)
5. Then “LD 7.0 mW $ 
” will be displayed.
6. Rotate the  l AMS L  knob so that the reading of the
laser power meter becomes the specified value, press the
YES   button and save it.
Note : Do not perform the emission with 7.0 mW more than 15
seconds continuously.
Laser power
meter
Optical pick-up
objective lens
Digital volt meter
BD board
CN105 pin 1 (I+3V)
CN105 pin 2 (IOP)
32
MDS-JE770
7. Then, rotate the  l AMS L  knob and display “LDPWR
CHECK”(C13).
8. Press the  YES  button once and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter become the speci-
fied value.
9. Press the  YES  button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value :
Laser power meter reading : LD 0.9mW : 0.85-0.91mW (260B)
0.90-0.96mW (260E)
  LD 7.0mW : 6.90-7.10mW (260B)
7.20-7.30mW (260E)
Digital voltmeter reading : Optical pick-up displayed value 
± 10%
(Optical pick-up label)
10. Press the  MENU/NO  button and display “LDPWR CHECK”
(C13) and stop the laser emission.
(The  MENU/NO  button is effective at all times to stop the
laser emission.)
11. Rotate the  l AMS L  knob to display “Iop.Write”(C05).
12. Press the  YES  button. When the display becomes Ref = @@@
.@ (@ is an arbitrary number), press the  YES  button to display
“Measu=@@@.@” (@ is an arbitrary number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Rotate the  l AMS L  knob.
To select the digit : Press the  l AMS L  knob
14. When the  YES  button is pressed, “Complete!” will be displayed
momentarily. The value will be recorded in the non-volatile
memory and the display will become “Iop Write”(C05).
Note 1: After step 4, each time the  YES  button is pressed, the
display will be switched between “LD 0.7 mW $ 
”, “LD
6.2 mW $ 
”, and “LD Wp 
 $ 
”. Nothing needs
to be performed here.
5-12. TRAVERSE  ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) of the BD board.
2. Load a test disc (MDW-74/GA-1). (Refer to Note 1.)
3. Press the  M  button and move the optical pick-up outside the
pit.
4. Rotate the  l AMS L  knob and display “EF MO
ADJUS”(C07).
5. Press the  YES  button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Rotate the  l AMS L  knob so that the waveform of the
oscilloscope becomes the specified value.
(When the  l AMS L  knob is rotated, the 
 of “EFB=
” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the  YES  button and save the result of adjustment to the
non-volatile memory (“EFB = 
 SAVE” will be displayed for a
moment. Then “EFB = 
 MO-W” will be displayed).
8. Rotate the  l AMS L  knob so that the waveform of the
oscilloscope becomes the specified value.
(When the  l AMS L  knob is rotated, the 
 of “EFB- 
MO-W” changes and the waveform changes.) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the wave-
form so that the specified value is satisfied as much as possible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the  YES  button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAVE” will be displayed for
a moment.)
10. “EFB = 
 MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and
servo is imposed.
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Oscilloscope
BD board
CN105 pin 4 (TE)
CN105 pin 6 (VC)
VC
A
B
Specification A = B
VC
A
B
Specification A = B
5-11. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the OP and when replacing the IC102.
Otherwise the OP check may deteriorate.
Note: Perform this function with the optical pick-up set at room
temperature.
Procedure
1. Rotate the  l AMS L  knob to display “Iop NV Save”
(C06).
2. Press the  YES  button and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, press the  YES
button.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 7.0 mW”.
5. After the display changes to “Iop=yysave?”, press the  YES
button.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.
KMS
260B
20101
H0576
Iop = 57.6 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
Ω)
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying IOP Information”.)
R
33
MDS-JE770
11. Rotate the  l AMS L  knob until the waveform of the
oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
12. Press the  YES  button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAVE” will be displayed for
a moment.)
Next “EF MO ADJUS” (C07) is displayed. The disc stops ro-
tating automatically.
13. Press the  A EJECT  button and remove the disc.
14. Load the check disc (MD) TDYS-1.
15. Roteto  l AMS L  knob and display “EF CD ADJUS”
(C08).
16. Press the  YES  button and display “EFB = 
 CD”. Servo is
imposed automatically.
17. Rotate the  l AMS L  knob so that the waveform of the
oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%.
Adjust the waveform so that the specified value is satisfied as
much as possible.
(Traverse Waveform)
18. Press the  YES  button, display “EFB = 
 SAVE” for a mo-
ment and save the adjustment results in the non-volatile memory.
Next “EF CD ADJUS”(C08) will be displayed.
19. Press the  A EJECT  button and remove the check disc (MD)
TDYS-1.
Note 1 : MO reading data will be erased during if a recorded disc is
used in this adjustment.
Note 2 : If the traverse waveform is not clear, connect the oscillo-
scope as shown in the following figure so that it can be
seen more clearly.
5-13. FOCUS BIAS ADJUSTMENT
Adjusting Procedure :
1. Load a test disk (MDW-74/GA-1).
2. Rotate the  l AMS L  knob and display “CPLAY1
MODE”(C34).
3. Press the  YES  button and display “CPLAY1 MID”.
4. Press the  MENU/NO  button when “C = 
 AD = 
” is
displayed.
5. Rotate the  l AMS L  knob and display “FBIAS
ADJUS”(C09).
6. Press the  YES  button and display “ 
/
 a = 
”.
The first four digits indicate the C error rate, the two digits after
[/] indicate ADER, and the 2 digits after [a =] indicate the focus
bias value.
7. Rotate the  l AMS L  knob in the clockwise direction and
find the focus bias value at which the C error rate becomes 220
(Refer to Note 2).
8. Press the  YES  button and display “ 
/
 b = 
”.
9. Rotate the  l AMS L  knob in the counterclockwise di-
rection and find the focus bias value at which the C error rate
becomes 220.
10. Press the  YES  button and display “ 
/
 c = 
”.
11. Check that the C error rate is below 20 and ADER is 00. Then
press the  YES  button.
12. If the “(
” in “
 - 
 - 
 (
” is above 20, press the  YES
button.
If below 20, press the  MENU/NO  button and repeat the
adjustment from step 2.
13. Press the  A EJECT  button to remove the test disc.
Note 1 : The relation between the C error and focus bias is as
shown in the following figure. Find points a and b in the
following figure using the above adjustment. The focal
point position C is automatically calculated from points a
and b.
Note 2 : As the C error rate changes, perform the adjustment using
the average vale.
VC
A
B
Specification A = B
VC
A
B
Specification A = B
330 k
Oscilloscope
10pF
BD board
CN105 pin 4 (TE)
CN105 pin 6 (VC)
C error
220
b
c
a
Focus bias value
(F. BIAS)
34
MDS-JE770
5-14. ERROR RATE CHECK
5-14-1. CD Error Rate Check
Checking Procedure :
1. Load a check disc (MD) TDYS-1.
2. Rotate the  l AMS L  knob and display “CPLAY1
MODE”(C34).
3. Press the  YES  button twice and display “CPLAY1 MID”.
4. The display changes to “C = 
 AD = 
”.
5. Check that the C error rate is below 20.
6. Press the  MENU/NO  button, stop playback, press the   A EJECT
button, and remove the test disc.
5-14-2. MO Error Rate Check
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “5-5. Using the Continuously Recorded Disc”.)
2. Rotate the l AMS L  knob and display “CPLAY1
MODE”(C34) .
3. Press the  YES  button and display “CPLAY1 MID”.
4. The display changes to “C = 
 AD = 
”.
5. If the C error rate is below 20, check that ADER is 00.
6. Press the  MENU/NO  button, stop playback, press the   A EJECT
button, and remove the test disc.
5-15. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Checking Procedure :
1. Load a continuously recorded test disc (MDW-74/GA-1).
(Refer to “5-5. Using the Continuously Recorded Disc”.)
2. Rotate the  l AMS L  knob and display “CPLAY1
MODE”(C34).
3. Press the  YES  button twice and display “CPLAY1 MID”.
4. Press the  MENU/NO  button when “C = 
 AD = 
” is
displayed.
5. Rotate the  l AMS L  knob and display “FBIAS CHECK”
(C16).
6. Press the  YES  button and display “ 
/
 c = 
”.
The first four digits indicate the C error rate, the two digits after
[/] indicate ADR, and the 2 digits after [c =] indicate the focus
bias value.
Check that the C error is below 20 and ADER is below 2.
7. Press the  YES  button and display “ 
/
 b = 
”.
Check that the C error is below 100 and ADER is below 2.
8. Press the  YES  button and display “ 
/
 a = 
”.
Check that the C error is below 100 and ADER is below 2
9. Press the  MENU/NO  button, next press the  A EJECT   button,
and remove the continuously recorded disc.
Note 1 : If the C error and ADER are above other than the speci-
fied value at points a (step 8. in the above) or b (step 7. in
the above), the focus bias adjustment may not have been
carried out properly. Adjust perform the beginning again.
5-16. AUTO GAIN CONTROL OUTPUT LEVEL
ADJUSTMENT
Be sure to perform this adjustment when the Optical pick-up is re-
placed.
If the adjustment results becomes “Adjust NG!”, the Optical pick-
up may be faulty or the servo system circuits may be abnormal.
5-16-1. CD Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the check disc (MD) TDYS-1.
2. Rotate the  l AMS L  knob to display “AG Set (CD)”
(C11).
3. When the  YES  button is pressed, the adjustment will be
performed automatically.
“Complete!!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (CD)”.
4. Press the   A EJECT  button to remove the disc.
5-16-2. MO Auto Gain Control Output Level Adjustment
Adjusting Procedure :
1. Insert the reference disc (MDW-74/GA-1) for recording.
2. Rotate the  l AMS L  knob to display “AG Set (MO)”
(C10).
3. When the  YES  button is pressed, the adjustment will be
performed automatically.
“Complete!!” will then be displayed momentarily when the value
is recorded in the non-volatile memory, after which the display
changes to “AG Set (MO)”(C10).
4. Press the   A EJECT  button to remove the disc.