– 61 –
Pin No.
Pin Name
I/O
Description
91
SRDR
O
Sled servo drive PWM signal (–) output to the BH6511FS (IC152)
92
SFDR
O
Sled servo drive PWM signal (+) output to the BH6511FS (IC152)
93
SPRD
O
Spindle servo drive PWM signal (–) output to the BH6511FS (IC152)
94
SPFD
O
Spindle servo drive PWM signal (+) output to the BH6511FS (IC152)
95
FGIN
I (S)
96
TEST1
I
97
TEST2
I
98
TEST3
I
99
DVSS
Ground terminal (digital system)
100
EFMO
O
EFM signal output terminal when recording mode
* I (S) stands for schmitt input, I (A) for analog input, O (3) for 3-state output, and O (A) for analog output in the column I/O.
Input terminal for the test (fixed at “L”)
– 62 –
 MAIN BOARD   IC501   M30624MG-223FP (SYSTEM CONTROLLER)
Pin No.
Pin Name
I/O
Description
1, 2
NC
O
Not used (open)
3
C1
O
Monitor output terminal for the test    C1 error rate is output when test mode
4
ADER
O
Monitor output terminal for the test    ADER is output when test mode
5
SQSY
I
Subcode Q sync (SCOR) input from the CXD2656R (IC121)
“L” is input every 13.3 msec    Almost all, “H” is input
6
RMC
I
Remote control signal input from the remote control receiver (IC761)
7
A1 IN
I
Sircs remote control signal input of the CONTROL A1II
8
BYTE
I
External data bus line byte selection signal input    “L”: 16 bit, “H”: 8 bit (fixed at “L”)
9
CNVSS
Ground terminal
10
XT-IN
I
Sub system clock input terminal (32.768 kHz)    Not used (open)
11
XT-OUT
O
Sub system clock output terminal (32.768 kHz)    Not used (open)
12
S.RST
I
System reset signal input from the LA5632 (IC431) and RESET switch (S401)    “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
13
XOUT
O
Main system clock output terminal (10 MHz)
14
GND
Ground terminal
15
XIN
I
Main system clock input terminal (10 MHz)
16
+3.3V
Power supply terminal (+3.3V)
17
NMI
I
Non-maskable interrupt input terminal (fixed at “H” in this set)
18
DQSY
I
Digital In U-bit CD format subcode Q sync (SCOR) input from the CXD2656R (IC121)
“L” is input every 13.3 msec    Almost all, “H” is input
19
P.DOWN
I
Power down detection signal input terminal    “L”: power down, normally: “H”
20
KEYBOARD CLK
I
Keyboard serial clock signal input terminal
21
KEYBOARD DATA
I
Keyboard serial data input terminal
22
NC
O
Not used (open)
23
XINT
I
Interrupt status input from the CXD2656R (IC121)
24 to 26
NC
O
Not used (open)
27
KEYBOARD CONT
O
Keyboard control signal output terminal    “H”: off
28 to 30
NC
O
Not used (open)
31
SWDT
O
Writing data output to the CXD2656R (IC121) and A/D, D/A converter (IC321)
32
SRDT
I
Reading data input from the CXD2656R (IC121)
33
SCLK
O
Serial clock signal output to the CXD2656R (IC121) and A/D, D/A converter (IC321)
34
FLCS
O
Chip select signal output to the FL/LED driver (IC771)
35
FLDATA
O
Serial data output to the FL/LED driver (IC771)
36
NC
O
Not used (open)
37
FLCLK
O
Serial data transfer clock signal output to the FL/LED driver (IC771)
38, 39
NC
O
Not used (open)
40
ADA LATCH
O
Serial data latch pulse signal output to the A/D, D/A converter (IC321)
41
NC
I
Not used (fixed at “L”)
42
JOG1
I
Jog dial pulse input from the rotary encoder (S713  
≠ AMS ±) (B phase input)
43
JOG0
I
Jog dial pulse input from the rotary encoder (S713  
≠ AMS ±) (A phase input)
44
NC
O
Not used (open)
45
A1 OUT
O
Sircs remote control signal output of the CONTROL A1
ΙΙ
46
NC
I
Not used (fixed at “H”)
47
NC
O
Not used (open)
48
DA RST
O
Reset signal output to the A/D, D/A converter (IC321)    “L”: reset
49
MUTE
O
Audio line muting on/off control signal output terminal    “L”: line muting on
– 63 –
Pin No.
Pin Name
I/O
Description
50
STB
O
Strobe signal output to the power supply circuit    “L”: standby mode, “H”: power on
51
CHACK IN
I
Detection input from the disc chucking-in detect switch     “L”: chucking
Not used (fixed at “H”)
52
NC
O
Not used (open)
53
PACK-OUT
I
Detection input from the loading-out detect switch (S602)
“L” at a load-out position, others: “H”
54
LDIN
O
Motor control signal output to the loading motor driver (IC471)    “L” active    *1
55
LDOUT
O
Motor control signal output to the loading motor driver (IC471)    “L” active    *1
56
LD-LOW
O
Loading motor drive voltage control signal output for the loading motor driver (IC471)
“H” active
57, 58
NC
O
Not used (open)
59
REC-P
I
Detection input from the recording position detect switch (S601)    “L” active
60
PB-P
I
Detection input from the playback position detect switch (S604)    “L” active
61
REC/PB
I
Not used (fixed at “L”)
62
+3.3V
Power supply terminal (+3.3V)
63
NC
O
Not used (open)
64
GND
Ground terminal
65
SDA
I/O
Two-way data bus with the EEPROM (IC171)
66
MNT3 (SLOCK)
I
Spindle servo lock status monitor signal input from the CXD2656R (IC121)
67
WR-PWR
O
Laser power select signal output to the CXD2656R (IC121) and HF module switch circuit
“L”: playback mode, “H”: recording mode
68
PROTECT
I
Rec-proof claw detect input from the protect detect switch (S102)    “H”: write protect
69
REFLECT
I
Detection input from the disc reflection rate detect switch (S102)
“L”: high reflection rate disc, “H”: low reflection rate disc
70
LDON
O
Laser diode on/off control signal output to the automatic power control circuit    “H”: laser on
71
SENS
I
Internal status (SENSE) input from the CXD2656R (IC121)
72
MNT1 (SHOCK)
I
Track jump detection signal input from the CXD2656R (IC121)
73
DIG-RST
O
Reset signal output to the CXD2656R (IC121) and BH6511FS (IC152)    “L”: reset
74
MNT2 (XBUSY)
I
Busy signal input from the CXD2656R (IC121)
75
XLATCH
O
Serial data latch pulse signal output to the CXD2656R (IC121)
Laser modulation select signal output to the HF module switch circuit
Stop: “L”, Playback power: “H”,
Recording power:
76
MOD
O
77
LIMIT-IN
I
Detection input from the sled limit-in detect switch (S101)
The optical pick-up is inner position when “L”
78
MNT0 (FOK)
I
Focus OK signal input from the CXD2656R (IC121)
“H” is input when focus is on (“L”: NG)
2 sec
0.5 sec
*1  Loading motor (M103) control
LOADING
EJECT
BRAKE
RUN IDLE
LDIN (pin %¢)
“L”
“H”
“L”
“H”
LDOUT (pin %∞)
“H”
“L”
“L”
“H”
Terminal
Mode
– 64 –
Pin No.
Pin Name
I/O
Description
79
SCL
O
Clock signal output to the EEPROM (IC171)
80
SCTX
O
Recording data output enable signal output to the CXD2656R (IC121) and overwrite head
driver (IC181)    Writing data transmission timing output (Also serves as the magnetic head on/off 
output)
81
CLOCK SET0
I
Destination setting terminal (fixed at “L” in this set)
82
CLOCK SET1
I
Destination setting terminal (fixed at “H” in this set)
83
LED0
O
LED drive signal output terminal    Not used (open)
84
LED1
O
LED drive signal output terminal    Not used (open)
85, 86
NC
O
Not used (open)
87
MODEL SEL0
I
Setting terminal for the model (fixed at “L” in this set)
88
MODEL SEL1
I
Setting terminal for the model (fixed at “L” in this set)
89, 90
NC
O
Not used (open)
91
TIMER
I
TIMER switch (S751) input terminal (A/D input)
“L”: PLAY, “H”: REC (OFF: center voltage)
92
SOURCE
I
INPUT switch (S741) input terminal (A/D input)
93
KEY3
I
Key input terminal (A/D input)    S731 and S732 (TIME, PITCH CONTOROL keys input)
94
KEY2
I
Key input terminal (A/D input)    S721 to S726 (
§ EJECT, PLAY MODE, REPEAT, SCROLL, 
LEVEL/DISPLAY/CHAR, I/
u keys input)
95
KEY1
I
Key input terminal (A/D input) 
S711 to S714 (MENU/NO, YES, PUSH ENTER, CLEAR keys input)
96
AVSS
Ground terminal
97
KEY0
I
Key input terminal (A/D input)    S701 to S706 (REC 
r , p, ), 0, P, · keys input)
98
VREF
I
Reference voltage (+3.3V) input terminal (for A/D converter)
99
+3.3V
Power supply terminal (+3.3V) (for analog system )
100
MONO/ST
I
REC MODE switch (S746) input terminal    “L”: MONO, “H”: STEREO
Page of 64
Display

Click on the first or last page to see other MDS-JE630 service manuals if exist.