Sony MDS-JE470 (serv.man2) Service Manual ▷ View online

5
MDS-JE470
SECTION 1
SERVICE NOTES
This appliance is classified as a
CLASS 1 LASER product. The
CLASS 1 LASER PRODUCT
MARKING is located on the
rear exterior.
Laser component in this product is capable
of emitting radiation exceeding the limit for
Class 1.
CAUTION
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radia-
tion exposure.
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
Flexible Circuit Board Repairing
• Keep the temperature of soldering iron around 270˚C
during repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
NOTES  ON  HANDLING  THE  OPTICAL  PICK-UP
BLOCK  OR  BASE  UNIT
The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
NOTES  ON  LASER  DIODE  EMISSION  CHECK
Never look into the laser diode emission from right above when
checking it for adjustment. It is feared that you will lose your sight.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 
0
 OR DOTTED LINE WITH
MARK 
0
 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE 
0
 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
This caution
label is located
inside the unit.
SAFETY  CHECK-OUT
(US model only)
    After correcting the original service problem, perform the fol-
lowing safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
    The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers). Leak-
age current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The “limit” indication is 0.75
V, so analog meters must have an accurate low-voltage scale.
The Simpson 250 and Sanwa SH-63Trd are examples of a pas-
sive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2V AC range are suitable. (See Fig. A)
Fig. A. Using an AC voltmeter to check AC leakage.
0.15
µ
F
To Exposed Metal
Parts on Set
1.5k
AC
voltmeter
(0.75V)
Earth Ground
6
MDS-JE470
JIG FOR CHECKING BD BOARD WAVEFORM
The special jig (J-2501-196-A) is useful for checking the waveform of the BD board. The names of terminals and the checking items to be
performed are shown as follows.
GND : Ground
I+3V : For measuring IOP (Check the deterioration of the optical pick-up laser)
IOP
: For measuring IOP (Check the deterioration of the optical pick-up laser)
TE
: TRK error signal (Traverse adjustment)
VC
: Reference level for checking the signal
RF
: RF signal (Check jitter)
FE
: Focus error signal
I+3V
Iop
GND
TE
FE
VC
RF
I+3V
IOP
GND
TE
FE
VC
RF
1
7
for
MDM-7A
I+3V
CN105
IOP
TE
VC
GND
FE
RF
7
MDS-JE470
Iop DATA RECORDING AND DISPLAY WHEN OPTICAL PICK-UP AND NON-VOLATILE MEMORY (IC195 OF
BD BOARD) ARE REPLACED
The Iop value labeled on the optical pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need to
look at the value on the label of the optical pick-up. When replacing the optical pick-up or non-volatile memory (IC195 of BD board), record
the Iop value on the optical pick-up according to the following procedure.
Record Precedure:
1. While pressing the  l AMS L  knob and  x  button, connect the power plug to the outlet, and release the  l AMS L  knob and
x  button.
2. Rotate the  l AMS L  knob to display “[Service]”, and press the  YES  button.
3. Rotate the  l AMS L  knob to display “Iop Write” (C05), and press the  YES  button.
4. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
5. Input the Iop value written on the optical pick-up.
To select the number : Rotate the  l AMS L  knob.
To select the digit
: Press the  l AMS L  knob.
6. When the  YES  button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the  YES  button.
8. “Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop
Write”.
9. Press the  REPEAT  button to complete.
Display Precedure:
1. While pressing the  l AMS L  knob and  x  button, connect the power plug to the outlet, and release the  l AMS L  knob and
x  button.
2. Rotate the  l AMS L  knob to display “[Service]”, and press the  YES  button.
3. Rotate the  l AMS L  knob to display “Iop Read” (C26).
4. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value labeled on the optical pick-up.
##.#
: indicates the Iop value after adjustment
5. To end, press the  l AMS L  button or  MENU/NO  button to display “Iop Read”. Then press the  REPEAT  button.
8
MDS-JE470
OPTICAL PICK-UP BLOCK TYPE DISCRIMINATION
There are two types of the optical pick-up block in this model.
These are compatible except  for the laser power.
Check the type of the optical pick-up block before replacement.
Ajdust  following items after replacing the optical pick-up block.
• 5-6-2. Laser Power Check (See page 28)
• 5-10. LASER POWER ADJUSTMENT (See page 31)
Differences
KMS-260B
       KMS-260E
Color of the adhesive agent at PDIC portion
Pink
White
Form of FPC retainer plate
Close the hole on SL base
Not close the hole on SL base
APC variable resistor
Small volume (2 type)
Big variable resistor (3 type) and chip resistor (Fig. A)
Small variable resistor (2 type) and chip resistor (Fig. B)
Fig. B type is for repair.
• Abbreviation
260B: KMS-260B model
260E: KMS-260E model
KSN-260B
KSN-260E
(Fig A)
(Fig B)
CHIP
3 type variable
resistor
2 type variable
resistor
CHIP
Hold on SL base
Hold on SL base
FPC retainer plate
FPC retainer plate
APC variable
resistor
Adhesive agent at 
PDIC portion
Adhesive agent at 
PDIC portion
Page of 70