— 13 —
SECTION  4
TEST MODE
4-1. PRECAUTIONS FOR USE OF TEST MODE
1 As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc is
stopped before setting and removing it.
Even if the 
§EJECT button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not
stop rotating.
Therefore, it will be ejected while rotating.
Be sure to press the 
§EJECT button after pressing the EDIT/NO button and the rotation of disc is stopped.
2 The erasing-protection tab is not detected in the test mode. Therefore, operating in the recording laser emission mode and pressing the
rREC button, the recorded contents will be erased regardless of the position of the tab. When using a disc that is not to be erased in the
test mode, be careful not to enter the continuous recording mode and traverse adjustment mode.
4-1-1. Recording laser emission mode and operating buttons
1.
Continuous recording mode (CREC MODE)
2.
Traverse adjustment mode (EFBAL ADJUST)
3.
Laser power adjustment mode (LDPWR ADJUST)
4.
Laser power check mode (LDPWR CHECK)
5.
When pressing the 
rREC button.
4-2. SETTING THE TEST MODE
While pressing the AMS knob, insert the power plug into the power supply outlet, and release the AMS knob.
4-3.  EXITING THE TEST  MODE
When the 1/u button is pressed, it becomes in the STANDBY mode. Or unplug the power plug from an outlet.
4-4. BASIC OPERATIONS OF THE TEST MODE
All operations are performed using the AMS knob, YES button, and EDIT/NO button.
The functions of these buttons are as follows.
Function name
AMS knob
YES button
EDIT/NO
 button
Function
Changes parameters and modes
Proceeds onto the next step. Finalizes input.
Returns to previous step. Stops operations.
4-5. SELECTING THE TEST MODE
Thirteen test modes are selected by turning the AMS knob.
Display
TEMP ADJUST
LDPWR ADJUST
LDPWR CHECK
EFBAL ADJUST
FBIAS ADJUST
FBIAS CHECK
CPLAY MODE
CREC MODE
DETRK CHECK
S curve CHECK
EEP MODE
MANUAL CMD
SVDATA READ
Contents
Temperature compensation offset adjustment
Laser power adjustment
Laser power check
Traverse adjustment
Focus bias adjustment
Focus bias check
Continuous playback mode
Continuous recording mode
Detrack check
S curve check 
Non-volatile memory mode 
Manual command transfer mode 
Data reading out mode 
For detailed description of each adjustment mode, refer to “5. Electrical Adjustments”.
If a different adjustment mode has been selected by mistake, press the EDIT/NO button to exit from this mode.
* The EEP MODE, S curve CHECK, MANUAL CMD and SVDATA READ are not used in servicing. If set accidentally, press the EDIT/NO
button immediately to exit this mode.
— 14 —
4
4
4-5-1. Operating the Continuous Playback Mode
1.
Entering the continuous playback mode
1 Set the disc in the unit. (Whichever recordable discs or discs for playback only are available.)
2 Rotate the AMS knob and display “CPLAY MODE”.
3 Press the YES button to change the display to “CPLAY MID”.
4 When access completes, the display changes to “C1 = 
 AD = 
”.
Note : The numbers “ ” displayed show you error rates and ADER.
2.
Changing the parts to be played back
1 Press the YES button during continuous playback to change the display as below.
 “CPLAY MID” 
n “CPLAY OUT”n “CPLAY IN”
When pressed another time, the parts to be played back can be moved.
2 When access completes, the display changes to “C1 = 
 AD = 
”.
Note : The numbers “ ” displayed show you error rates and ADER.
3.
Ending the continuous playback mode
1 Press the EDIT/NO button. The display will change to “CPLAY MODE”.
2 Press the §EJECT button to remove the disc.
Note : The playback start addresses for IN, MID, and OUT are as follows. In case you want to display the address of the playback position
on the display, press the DISPLAY/CHAR button and display “CPLAY (
)”.
IN
40h cluster
MID 300h cluster
OUT 700h cluster
4-5-2.
Operating the Continuous Recording Mode
1.
Entering the continuous recording mode
1 Set a recordable disc in the unit. (Refer to Note 3)
2 Rotate the AMS knob and display “CREC MODE”.
3 Press the YES button to change the display to “CREC MID”.
4 When access completes, the display changes to “CREC (
)” and  
REC
  lights up.
Note : The numbers “ ” displayed shows you the recording position addresses.
2.
Changing the parts to be recorded
1 When the YES button is pressed during continuous recording, the display changes as below.
“CPLAY MID” 
n “CPLAY OUT”n “CPLAY IN”
When pressed another time, the parts to be recorded can be changed.   
REC
  goes off.
2 When access completes, the display changes to “CREC (
)” and  
REC
  lights up.
Note : The numbers “ ” displayed shows you the recording position addresses.
3.
Ending the continuous recording mode
1 Press the EDIT/NO button. The display changes to “CREC MODE” and  
REC
  goes off.
2 Press the §EJECT button to remove the disc.
Note 1 : The recording start addresses for IN, MID, and OUT are as follows.
IN
40h cluster
MID
300h cluster
OUT
700h cluster
Note 2 : The EDIT/NO button can be used to stop recording anytime.
Note 3 : During the test mode, the erasing-protection tab will not be detected. Therefore be careful not to set the continuous recording
mode when a disc not to be erased is set in the unit.
Note 4 : Do not perform continuous recording for long periods of time above 5 minutes.
Note 5 : During continuous recording, be careful not to apply vibration.
4-5-3. Non-Volatile Memory Mode
This mode reads and writes the contents of the non-volatile memory.
It is not used in servicing. If set accidentally, press the EDIT/NO button immediately to exit it.
— 15 —
P
REC
CLOCK
TRACK
DISC
DATE
A. SPACE
A – B
      Focus auto gain successful
      Tracking auto gain failed
During continuous playback
Tracking servo OFF
Recording mode ON
CLV LOCK
Pit
High reflection
CLV-S
ABCD adjustment completed
    Focus auto gain successful
    Tracking auto gain successful
4-6. FUNCTIONS OF OTHER BUTTONS
Contents
Sets continuous playback when pressed in the STOP state. When pressed during continuous playback, the tracking servo turns ON/OFF.
Stops continuous playback and continuous recording.
The sled moves to the outer circumference only when this is pressed.
The sled moves to the inner circumference only when this is pressed.
Turns recording ON/OFF when pressed during continuous playback.
Switches the display when pressed.Returns to previous step. Stops operations.
Function
·
p
)
0
r REC
DISPLAY/
CHAR
Note : The erasing-protection tab is not detected during the test mode. Recording will start regardless of the position of the erasing-protection
tab when the 
r REC button is pressed.
4-7. TEST MODE DISPLAYS
Each time the DISPLAY/CHAR button is pressed, the display changes in the following order.
MODE display
nError rate displaynAddress displaynAuto gain displaynIVR display
The auto gain display and the IVR display are not used for servicing.
1.
MODE display
Displays “TEMP ADJUST”, “CPLAY MODE”, etc.
2.
Error rate display
Error rates are displayed as follows.
C1 = 
 
AD = 
C1 = : Indicates C1 error
AD = : Indicates ADER
3.
Address display
Addresses are displayed as follows. (MO : Recordable disc, CD : Disc for playback only)
h = 
s = 
 (MO pit and CD)
h = 
a = 
 (MO groove)
h = : Header address
s = : SUBQ address
a = : ADIP address
* “_” is displayed when the address cannot be read.
4.
Auto gain display
Auto gains are displayed as follows.
AG F = 
T = 
F= Focus auto gain collection value.
T= Tracking auto gain collection value.
4-8. MEANINGS OF OTHER DISPLAYS
Display
Contents
Light
Off
Blinking
STOP
Tracking servo ON
Recording mode OFF
CLV UNLOCK
Groove
Low reflection
CLV-A
                                            
                                            
                                           
                                           
— 16 —
SECTION  5
ELECTRICAL ADJUSTMENTS
5-1. PRECAUTIONS FOR CHECKING LASER
DIODE EMISSINON
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
5-2. PRECAUTIONS FOR USE OF OPTICAL PICK-
UP (KMS-260A)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board when using it.
Before disconnecting the connector, desolder first. Before connecting
the connector, be careful not to remove the solder. Also take adequate
measures to prevent damage by static electricity. Handle the flexible
board with care as it breaks easily.
pick-up
flexible board
laser tap
1.Temperature
   compensation
   offset adjustment
2. Laser power
    adjustment
3. Traverse
    adjustment
4. Focus bias
    adjustment
5. Error rate check
Optical
Pick-up
IC101, IC121, IC192
D101
IC171
¬
¬
¬
¬
¬
G
¬
¬
¬
¬
¬
G
G
G
G
¬
¬
¬
¬
¬
BD Board
5-3. PRECAUTIONS FOR ADJUSTMENTS
1)
When replacing the following parts, perform the adjustments
and checks with 
¬ in the order shown in the following table.
2)
Set the test mode when performing adjustments.
After completing the adjustments, exit the test mode.
3)
Perform the adjustments in the order shown.
4)
Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Parts No. 4-963-646-01)
• Laser power meter LPM-8001 (Parts No. J-2501-046-A)
• Oscilloscope (Measure after performing CAL of prove.)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Parts No. : J-2501-124-A)
5)
When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited.)
6)
Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Note on page 4.)
Note : When performing laser power checks and adjustment
(electrical adjustment), use of the new MD laser power meter
8010S (J-2501-145-A) instead of the conventional laser power
meter is convenient.
It sharply reduces the time and trouble to set the laser power
meter sensor onto the objective lens of the pick-up.
5-4. CREATING CONTINUOUSLY RECORDED DISC
• This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording disc.
1.
Insert a disc (blank disc) commercially available.
2.
Rotate the AMS knob and display “CREC MODE”.
3.
Press the YES button again to display “CREC MID”.
Display “CREC (0300)” and start to recording.
4.
Complete recording within 5 minutes.
5.
Press the EDIT/NO button and stop recording .
6.
Press the 
§EJECT button and remove the disc.
The above has been how to create a continuous recorded data for the
focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
Optical pick-up flexible board