Sony MDS-JB940 Service Manual ▷ View online

21
Display
N
X
SYNC (other models/TOC EDIT)
L. SYNC (other models/A.SPACE)
OVER
B/1 (REP portion)
A-REP
TRACK/(LP)4/calender frame
DISC/LP2
SLEEP/SHUF
MONO
When Lit
Servo ON
Tracking servo OFF
Recording mode ON
CLV low speed mode
ABCD adjustment completed
Tracking offset cancel ON
Tracking auto gain OK
Focus auto gain OK
Pit
High reflection
CLV-S
CLV LOCK
When Off
Servo OFF
Tracking servo ON
Recording mode OFF
CLV normal mode
Tracking offset cancel OFF
Groove
Low reflection
CLV-A
CLV UNLOCK
4-8. MEANINGS OF OTHER DISPLAYS
REC
Contents
4-9. AUTO DIAGNOSIS FUNCTION
This test mode automatically performs C-REC and C-PLAY and checks mainly the characteristics of the optical pick-up. To execute the test
mode, first check the laser power and perform AUTO CHECK after Iop Compare.
[Operation Procedure]
1.
Press the  YES  button. If “LDPWR 
 ” appears, which means the laser power has not been checked, first check the laser power and
perform Iop Compare. Then, repeat this step.
2.
If there is a disc in the mechanism deck, the disc is forcibly ejected.
After “DISC IN” appears, load a recordable test disc (MDW-74/GA-1).
3.
When the disc is loaded in step 2, the check automatically starts.
4.
While “XX CHECK” is displayed, the check of the item shown in “XX” is in progress.
After “06 check” is complete, eject the disc loaded in step 2. When “DISC IN” appears, load the TDYS-1 check disc (MD).
5.
After the disc loaded in step 4 is loaded, the check automatically restarts from “07 CHECK”.
6.
After the check of item 12 is complete, “OK” or “NG” appears. When all items are OK, “CHECK ALL OK” appears. If even one of the
items failed, “NG: xxxx” appears.
When “CHECK ALL OK” appears, there is no problem in the optical pick-up. Check the operations of the spindle motor, sled motor, etc.
If “NG: xxxx” appears, there is an abnormality in the optical pick-up. Replace the optical pick-up.
4-10.
INFORMATION
The version of the software is displayed.
[Operation Procedure]
1.
When “INFORMATION” appears, press the  YES  button.
2.
The version of the software is displayed.
3.
Press the  MENU/NO  button to end this mode.
4-11.
MEASURE WHEN “MEMORY NG” APPEARS
If there is an abnormality in the data of the non-volatile memory, “E001” or “MEMORY NG” appears so that the MD mechanism deck does
not continue to be operated. If either of these messages appears, immediately enter the test mode and perform the following operation.
[Operation Procedure]
1.
Enter the test mode. (Refer to Section 4-2.)
2.
Normally, the test mode selection display appears. If there is an abnormality in the non-volatile memory, the message “INIT EEP?”
appears.
3.
Press the  x  button and the  EJECT A button at the same time.
4.
Turn the  l AMS L  knob to select “MDM-7A”.
5.
Press the  l AMS L  knob. After the non-volatile memory is rewritten, the mode returns to the normal test mode and the test mode
selection display appears.
22
SECTION  5
ELECTRICAL  ADJUSTMENTS
5-1. PARTS  REPLACEMENT  AND  ADJUSTMENT
If a defect such as dropout caused by the OP is found, check the following.
Check Procedure Before Replacement
NG
NG
NG
OK
OK
OK
Start
Laser power check
Iop Compare
AUTO CHECK
Replace the OP 
or replace the 
MDM.
Mechanism check of sled, etc.
Other cause is likely. 
23
Flow During Adjustment
Start
Replace IC195.
After turning on the power again, initialize 
EEPROM.
Replace either OP or IC195.
ADJ CLEAR
Replace either IC101, IC195 or D101.
Replace either OP, IC190 or IC195.
Replace either 
OP, IC102, IC190 or IC195.
Replace either 
OP, IC101, IC151 or IC195.
Replace the OP.
op change in Err Display mode
Iop Write
Replace the spindle motor.
spdl change in Err Display mode
AUTO CHECK
End adjustment.
TEMP ADJUST
LDPWR ADJUST
Iop NV Save
EF MO, CD ADJUST
FBIAS ADJUST
AG SET (MO), (CD)
YES
YES
YES
YES
YES
YES
YES
YES
24
5-2. PRECAUTIONS FOR CHECKING LASER
DIODE EMISSION
To check the emission of the laser diode during adjustments, never
view directly from the top as this may lose your eye-sight.
5-3. PRECAUTIONS FOR USE OF OPTICAL
PICK-UP (KMS-260B)
As the laser diode in the optical pick-up is easily damaged by static
electricity, solder the laser tap of the flexible board of the optical
pick-up when using it.
Before disconnecting the connector, desolder first. Before connecting
the connector, be careful not to remove the solder. Also take adequate
measures to prevent damage by static electricity. Handle the flexible
board with care as it breaks easily.
Optical pick-up flexible board
5-4. PRECAUTIONS FOR ADJUSTMENTS
1.
When replacing the following parts, perform the adjustments
and checks with a in the order shown in the following table.
2.
Set the test mode when performing adjustments.
After completing the adjustments, release the test mode.
3.
Perform only the adjustments to be needed in the order shown.
Initial setting of
adjustment value
Recording of
Iop information
TEMP
CHECK
Laser power
adjustment
Iop NV Save
Traverse
adjustment
Focus bias
adjustment
Auto gain
adjustment
AUTO
CHECK
4.
Use the following tools and measuring devices.
• Check Disc (MD) TDYS-1
(Part No. 4-963-646-01)
• Test Disc (MDW-74/GA-1) (Part No. 4-229-747-01)
• Laser power meter LPM-8001 (Part No. J-2501-046-A)
or
• MD Laser power meter 8010S (Part No. J-2501-145-A)
• Oscilloscope (Measure after performing CAL of prove)
• Digital voltmeter
• Thermometer
• Jig for checking BD board waveform
(Part No. : J-2501-196-A for MDM-7A)
5.
When observing several signals on the oscilloscope, etc.,
make sure that VC and ground do not connect inside the
oscilloscope.
(VC and ground will become short-circuited)
6.
Using the above jig enables the waveform to be checked without
the need to solder.
(Refer to Servicing Notes on page 6)
7.
As the disc used will affect the adjustment results, make sure
that no dusts nor fingerprints are attached to it.
Laser power meter
When performing laser power checks and adjustment (electrical
adjustment), use of the new MD laser power meter 8010S (Part No.
J-2501-145-A) instead of the conventional laser power meter is
convenient.
It sharply reduces the time and trouble to set the laser power meter
sensor onto the objective lens of optical pick-up.
5-5. CREATING CONTINUOUSLY-RECORDED
DISC
* This disc is used in focus bias adjustment and MO error rate check.
The following describes how to create an MO continuous recording
disc.
1.
Insert a disc (MDW-74/GA-1)(blank disc) commercially
available.
2.
Turn the  l AMS L  knob and display “CREC 1 MODE”
(C35).
3.
Press the  YES  button again to display “CREC 1 MID”.
Display “CREC (0300)” and start to recording.
(Complete recording within 5 minutes.)
4.
Press the  MENU/NO  button and stop recording .
5.
Press the  EJECT A button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and MO error rate check.
Note:
Be careful not to apply vibration during continuous recording.
Pick-up
Flexible board
Laser tap
Optical
Pick-up
a
a
×
a
a
a
a
a
a
Replacement parts
IC101
×
×
a
×
×
a
a
a
a
IC102
×
×
×
×
a
×
×
×
×
IC151
×
×
×
×
×
a
a
a
a
IC190
×
×
×
a
a
×
×
×
a
IC195
a
a
a
a
a
a
a
a
a
D101
×
×
a
×
×
×
×
×
×
Page of 74
Display