DOWNLOAD Sony ICF-C620L Service Manual ↓ Size: 355.7 KB | Pages: 17 in PDF or view online for FREE

Model
ICF-C620L
Pages
17
Size
355.7 KB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
icf-c620l.pdf
Date

Sony ICF-C620L Service Manual ▷ View online

– 5 –
3-3. MAIN BOARD
6
 CN51
4
 marker
1
 claw
3
 claws
2
 knob (FUNC)
7
 wire (To SERVO board)
8
 wire (To speaker)
5
 CN50
!™
 sheet (BAND)
 knob (TUNE)
 MAIN board
variable capacitor
 P 3x12
9
 wire
Note : When installing, turn the variable capacitor fully in the drection of the arrow.
Refer to 3-6. POINTER SETTING for installation of the knob (TUNE).
– 6 –
3-4. LID (CASSETTE)
6
 P 2x10
2
 BTP 2x8
1
 wire (To motor)
4
 claws
8
 mechanism deck assy
5
 spring (MD)
3
 claws
1
 spring (door)
3
 claw
2
 claw
4
 lid (cassette)
3-5. MECHANISM DECK ASSY
7
 bracket (MD)
– 7 –
3-6. POINTER SETTING
1) Align the first slot on the pointer with the rib of the cabinet (front). <Fig. 1>
2) Align the slot on the knob (TUNE) with the slot on the pointer and install the knob. <Fig. 2>
knob (TUNE)
<Fig. 2>
<Fig. 1>
slot
pointer
rib
slot
pointer
knob (TUNE)
– 8 –
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
capstan
rubber belts
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustment apply suitable locking compound to the
parts adjusted.
5. The adjustment should be performed with the rated power supply
voltage unless otherwise noted.
Torque Measurement
Mode
Torque Meter
Meter Reading
30 – 60 g • cm
Forward
CQ-102C
(0.42 – 0.83 oz • inch)
Fast Forward
55 – 140 g • cm
and Rewind
CQ-201B
(0.76 – 1.94 oz • inch)
Back
1 – 5 g • cm
Tension
CQ-102C
(0.014 – 0.069 oz • inch)
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1.   TAPE PLAYER SECTION
• Test Tape
Type
Signal
Used for
P-4-A063
6.3 kHz, – 10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 dB
tape speed adjustment
Playback Head Azimuth Adjustment
Setting :
VOLUME control : mechanical mid
Procedure :
1. Mode : playback
set
test tape
P-4-A063
(6.3 kHz, – 10 dB)
level meter
speaker terminal
2. Turn the adjustment screw to obtain the maximum reading on
level meter.
Note :
 Several peaks may appear but take the maximum.
3. After the adjustment, lock the adjustment screw with suitable
locking compound.
Adjustment Location :
Adjustment Value :
Speed checker Adjustment point
Digital frequency
counter
±
 3 %
VR2
2,910 to 3,090 Hz
Frequency difference between the beginning and the end of the tape
should be within 
±
 1% (30 Hz).
Adjustment Location : servo board (component side)
set
test tape
WS-48A
(3 kHz, 0 dB)
speed checker
LFM-30
           or
digital frequency
counter
speaker terminal
Tape Speed Adjustment
Setting :
VOLUME control : mechanical mid
Procedure :
1. Mode : playback
adjustment screw
VR2
TAPE
SPEED
ADJ
Page of 17
Display