ICD-UX502
13
4.  OPERATION  OF  THE  TEST  MODE
4-1. VERSION
Model name, destination, fi rmware version, IPL2 version, CPU 
version, initial language, charge function, card function, radio 
function, eMMC maker code and eMMC capacity can be con-
fi rmed.
Procedure:
1.  Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “VERSION”, and 
press the [
N
/ENTER] key.
3. Model name, destination, fi rmware version, IPL2 version and 
CPU version are displayed on page 1/2 of LCD display. Press 
the [
>
] or [
.
] keys, initial language, charge function, 
card function, radio function, eMMC maker code and eMMC 
capacity are displayed on page 2/2 of LCD display.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<VERSION>
ICD-UX502/CE7
MAINFW:1.00.01
IPL2FW:1.00.00
LSI 4252
LCD Display (page 1/2)
<VERSION>
L:02 C0M0R0
eMMC MCode 15
eMMC Capa 02GB
LCD of Display (page 2/2)
eMMC maker code
eMMC capacity
Model name/Destination
Firmware version
IPL2 version
CPU version
Initial language
       
Charge function
Card function
Radio function
 
C/M/R : 1 = function exists
 
 
0 = function non-exists
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-2. KEY CHECK
Operation of keys and switches can be checked, and this unit can 
return to the factory shipment settings.
Note 1: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “KEY CHECK”, 
and press the [
N
/ENTER] key.
3.  Whenever any keys of this unit are pressed or any switches of 
this unit are slid, the button count decreases.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
<KEY CHECK>
LCD Display
KEY:PREV
REMAIN: 15
Button count 
Confirmed key name
 
Target keys:
 
[STOP/
x
], [>], [.], [
N
/ENTER], [REC/PAUSE/
z
], 
 
[
 /
A-B], [ERASE], [VOL +], [VOL –], [MENU], [FOLDER], 
 [T-MARK], 
[
v
], [
V
]
 
Target switches:
 
[DPC (SPEED CTRL)] (ON, OFF), [HOLD•POWER] 
(“POWER” direction, return from “POWER” direction, 
“HOLD” direction, return from “HOLD” direction)
4.  After all the keys and switches are decided, initialization is 
performed.
5.  “Success” is displayed, and this unit reboots. 
Note 2: This unit is not initialized when “Failure” is displayed.
Releasing method:
Remove battery.
ICD-UX502
14
4-3. AUDIO LOOP
Audio loop back operation can be performed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “AUDIO LOOP”, 
and press the [
N
/ENTER] key.
3.  Audio loop back operation is performed.
 
(Displayed characters/values in the following fi gure are ex-
ample)
Note: When mode is active, the recording level for VOR is acquired at in-
tervals of 1 second, and it is displayed. When the acquired recording 
level is larger than the VOR setting value, the operation indicator 
LED redly lights up.
 
(Threshold value is based on operation of this unit)
<AUDIO LOOP>
MIC: M AGC: OFF
Vol: 10 MIC IN
D H0 D0
VOR: 00003FFF
D: DAMP, (A: Codec)
H0: HP_MUTE=L, (H1: H)
D0: DAMP_XSEL=L, (D1: H)
LCD Display
 
Initial value:
 
Play back volume 
: 10 (stereo)
 
fs 
: 44.1 kHz
 
Microphone sensitivity  : M
 
External microphone 
: MIC IN
 HP_MUTE 
L
 DAMP_XSEL 
L
 
Sound is outputted from the D-AMP built-in CPU at the time 
of headphone wearing.
 
Key input settings under this mode of operation:
 
[VOL +] 
: Volume up
 
[VOL –] 
: Volume down
 [REC/PAUSE/
z
] : Microphone sensitivity change 
 
 
  (H → L → M → H...)
 
[
N
/ENTER] 
: External microphone sensitivity
 
 
  (mounted model only)
 
 
  (MIC IN ↔ LINE IN)
 
[
.
: AGC operation (ON ↔ OFF)
 
[
>
: The headphone amplifi er change
 
 
  (mounted model only)
 
 
  (D-AMP ↔ Codec)
 
[ERASE] 
: HP_MUTE forcible operation
 
 
  Only HP_MUTE is changed with a 
 
 
  play back state held (ON ↔ OFF).
 
[
 /
A-B] 
: DAMP_XSEL forcible operation
 
 
  Only DAMP_XSEL is changed with
 
 
  a play back state held (ON ↔ OFF).
Operation of others by the plug/unplug signal (the external micro-
phone jack and headphone jack) are based on operation of this unit.
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-4. SIN
Sine wave can be outputted.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “SIN”, and press 
the [
N
/ENTER] key.
3.  Sine wave is outputted.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<SIN>
Vol:10
LCD Display
 
Initial value:
 
Play back volume  : 10 (stereo)
 fs 
44.1kHz
 
Sound is outputted from the D-AMP built-in CPU at the time 
of headphone wearing.
 
Key input settings under this mode of operation:
 
[VOL +]  : Volume up
 
[VOL –]  : Volume down
Operation of others by the plug/unplug signal (the external micro-
phone jack and headphone jack) are based on operation of this unit.
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-5. BEEP
Beep sound (1.3 kHz) can be outputted.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “BEEP”, and press 
the [
N
/ENTER] key.
3.  Beep sound (1.3 kHz) is outputted.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<BEEP>
1.3KHz ON
Vol:10
LCD Display
 
Key input settings under this mode of operation:
 
[VOL +]  : Volume up
 
[VOL –]  : Volume down
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
ICD-UX502
15
4-6. LCD CONT
LCD contrast can be adjusted.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “LCD CONT”, and 
press the [
N
/ENTER] key.
3.  Adjustment of LCD contrast becomes available.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<LCD CONT>
Vol: 16
[FF]+ [FR]
[PLAY] Save
LCD Display
 
Initial value:
 
The default setting saved at eMMC.
 
Key input settings under this mode of operation:
 
[.] 
: Contrast value decrease
 
[>] 
: Contrast value increase
 
[
N
/ENTER]  : The current contrast value is written to eMMC.
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-7. LCD PATTERN
The lighting check of LCD can be performed.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “LCD PATTERN”, 
and press the [
N
/ENTER] key.
3.  LCD display pattern is displayed as shown in the following 
fi gure.
‡
‡
‡‡‡‡
LCD Display Pattern
All segments ON
All segments OFF
Partial segments ON
 
Key input settings under this mode of operation:
 
[
>
] or [
.
] : Display pattern change
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-8. RTC TEST
The self-test of RTC module can be done.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “RTC TEST”, and 
press the [
N
/ENTER] key.
3.  The self-test of RTC module is executed, and result is dis-
played.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
<RTC TEST>
OK
LCD Display
RTC self-test result
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-9. BATT A/D
A/D value (voltage value and temperature value) acquisition can 
be performed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “BATT A/D”, and 
press the [
N
/ENTER] key.
3.  A/D value (voltage value and temperature value) are acquired, 
and they are displayed.
 
(8 bit (The bit shift after LSB side 2 bit omission))
 
Displayed values are always updated.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
<BATT A/D>
AC: 7B  2AC: 00
BC: 7B  4BC: 00
TEMP: 00
LCD Display
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
ICD-UX502
16
4-10. ZLOAD
The battery load check can be operated compulsorily.
Procedure:
1.  Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “ZLOAD”, and 
press the [
N
/ENTER] key.
3.  ON/OFF of ZLOAD is changed.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<ZLOAD>
ZLOAD : OFF
LCD Display
 
Key input settings under this mode of operation:
 
[
>
] or [
.
]  : ZLOAD_CTL change (H ↔ L)
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-11. LOW 
DET
LOWBATT_XDET (Battery voltage decrease detection signal) 
can be checked.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “LOW DET”, and 
press the [
N
/ENTER] key.
3.  The state of LOW DET is displayed.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<LOW DET>
LOW DET: OFF
LCD Display
 
OFF : LOWBATT_XDET=1 (H)
 
ON  : LOWBATT_XDET=0 (L)
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-12. VBUS
VBUS detection signal can be checked.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “VBUS”, and press 
the [
N
/ENTER] key.
3.  The state of VBUS_XDET is displayed.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<VBUS>
OFF
LCD Display
 OFF 
VBUS_XDET=1 
(H)
 ON 
VBUS_XDET=0 
(L)
 
Key input settings under this mode of operation:
 
[
N
/ENTER]  : It shifts to the suspension state.
 
 
  Remove battery, in order to be released from 
 
 
  the suspension state.
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-13. KEY 
COUNT
The count value of the keys and switches operation can be dis-
played. However, distinction of kind of the keys and switches 
which operated is not performed.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “KEY COUNT”, 
and press the [
N
/ENTER] key.
3.  The count value of the keys and switches operation is dis-
played.
 
(Displayed characters/values in the following fi gure are ex-
ample)
<KEY COUNT>
00888
LCD Display
 
Count value increase conditions:
 
One of buttons is pushed.
 
One of switches is slid.
 
Headphone or microphone is inserted.
Releasing method:
Remove battery.
Page of 24