ICD-SX700/SX700D/SX800/SX800D/SX900
5
Display during recording
RH Operating mode indicator
Displays the following, depending
on the current operation of the IC
recorder.
: recording
: Flashes while recording
standby/recording pause
: recording with the VOR
function
: recording pause with the
VOR function
If you press
[
(record/pause) to
pause recording when “VOR” is set to
“ON” in the menu, only “
: Synchronized recording
: Flashes while
synchronized recording is set to
pause.
RI Recording level meter
RK Recording level indicator
Displays the current microphone
sensitivity when recording.
: To record for dictation or in a
noisy place.
: To record at a meeting or in a
quiet/spacious place.
: To record with further high
sensitivity.
: To record music.
Displays the recording level during
manual recording.
RL Elapsed recording time/Pre-
recording standby time indication
If there is more than 100 hours time
remaining, the time is displayed in
hours and minutes.
If there is less than 100 hours time
remaining, the time is displayed in
hours, minutes and seconds.
When “PRE REC” is set to “ON” in the
menu, the pre-recording standby
time is displayed in seconds between
0 and 5.
RM Alarm indicator
X Recoding mode indicator
Displays the recording mode set in
the menu.
XB Limiter indicator
: When “LIMITER” is set to “ON”
in the menu.
: When you are recording in
other than the manual recording
mode.
XT Remaining recording time indication
XE Battery indicator
XG LCF (Low Cut Filter) indicator
: When “LCF (LOW CUT)” is set
to “ON” in the menu.
: When “LCF (LOW CUT)” is set
to “OFF” in the menu.
Step 2: Setting the
Clock
Y
,
/MENU
/Y
You need to set the clock to use the
alarm function or record the date and
time.
Clock setting display appears when
you insert batteries for the
time, or
when you insert batteries after the IC
recorder has been without batteries for
a certain period of time, “SET DATE &
TIME” appears, and then the year section
in the display window.
Continued directly from
“Step 1: Preparing a Power
Source”
1
Press
 or 
to set the year,
month, day, hour, and minute in 
sequence, then press
/Y
.
“EXECUTING….” appears and the clock
is set.
2
Press
Y
(stop) to return to the 
display of the stop mode.
Setting the clock using the 
menu
While the IC recorder is in the stop mode,
you can set the clock using the menu.
1
Select “DATE & TIME” in the menu.
Press and hold
/MENU to enter the
menu mode.
The menu mode window will be
displayed.
Press
or
to select “DETAIL
MENU,” then press
/Y
.
Press
or
to select “DATE &
TIME,” then press
/Y
.
2
Press
or
to select “AUTO”
or “MANUAL” and press
/Y
.
When you selected “AUTO,” the clock is
automatically adjusted using the clock
in the computer connected to the IC
recorder and on which the supplied
Digital Voice Editor software is started.
When you select “MANUAL,” proceed
to the next steps.
3
Press the
or
to select
“09y1m1d,” then press
/Y
.
4
Press
or
to set the year,
month, day, hour, and minute in
sequence, then press
/Y
.
“EXECUTING….” appears and the clock
is set.
5
Press
Y
(stop) to return to the
display of the stop mode.
Tips
Press
/MENU to return to the previous
operation.
You can set the time display for the clock to
“12-HOUR” or “24-HOUR” in the menu. When
“12-HOUR” is set, “AM” or “PM” appears in the
display window.
Note
If you do not press
/Y
within one minute
of entering the clock setting data, the clock
setting mode is cancelled and the window will
return to the display of the stop mode.
To display the current time
Slide the HOLD switch in the direction of
the arrow to display the current time.
[
[
[
1
ICD-SX700/SX700D/SX800/SX800D/SX900
6
SECTION  2
DISASSEMBLY
•  This set can be disassembled in the order shown below.
2-1. SPEAKER 
ASSY 
(SP001)
 
(Page  7)
SET
2-2.  BATTERY CASE LID ASSY
 (Page 
7)
2-3. CASE 
ASSY
 (Page 
8)
2-7. AUDIO 
BOARD
 (Page 
10)
2-8. JACK 
BOARD
 (Page 
10)
2-9. MICROPHONE 
CAP,
 MICROPHONE 
HOLDER
 (Page 
11)
2-10.  MIC101, MIC102, MIC103
 (Page 
11)
2-4.  AUDIO BOARD SECTION,
 CHASSIS 
SECTION,
 SWITCH 
BOARD
 (Page 
8)
2-5.  MAIN BOARD   
 (Page 
9)
2-6.  LIQUID CRYSTAL DISPLAY PANE (LCD101)
 (Page 
9)
ICD-SX700/SX700D/SX800/SX800D/SX900
7
Note: Follow the disassembly procedure in the numerical order given.
2-1.  SPEAKER  ASSY (SP001)
2-2.   BATTERY  CASE  LID  ASSY
 two screws (M1.4)
 base
 speaker assy (SP001)
 knob (side)
claw
claw
 two claws
 three knobs (hold)
claw
claw
 screw
 screw (M1.4)
 battery case lid assy
ICD-SX700/SX700D/SX800/SX800D/SX900
8
2-3.   CASE  ASSY
2-4.   AUDIO  BOARD  SECTION,  CHASSIS  SECTION,  SWITCH  BOARD
 screw (M1.4)
 screw (M1.4)
 case assy
 spacer (ornamental belt)
 chassis assy
When assembling the chassis assy, 
adjust the switches in the direction 
of the arrow.
switch
switch
switch
switch
 AUDIO board section
 two claws
 two claws
 sheet (microphone jack)
 Remove the solder.
RB chassis section
battery terminal (detection)
 SWITCH board
 claw
 CN7002
CN1001
sheet (microphone jack)
Sheet (microphone jack) attachment position 
is shown.
CN7001
Page of 52