Sony ICD-PX440 (serv.man2) Service Manual ▷ View online
ICD-PX440
10
2-8. ELECTRET CAP MICROPHONE (L/R-ch) (MIC1, MIC2)
3 electret cap microphone
(L-ch) (MIC1)
3 electret cap microphone
(R-ch) (MIC2)
electret cap microphone
cushion (MIC)
2
cushion (MIC)
1
Remove the electret cap microphone
(L-ch) (MIC1) block in the direction of
the arrow.
(L-ch) (MIC1) block in the direction of
the arrow.
1
Remove the electret cap microphone
(R-ch) (MIC2) block in the direction of
the arrow.
(R-ch) (MIC2) block in the direction of
the arrow.
2
cushion (MIC)
electret cap microphone
cushion (MIC)
Sticks out from the side.
OK
NG
Note: When installing the cushion (MIC), begin affixing the cushion (MIC)
at the position where the lead wire comes out, and affix it so that the
cushion winds around the side of the electret cap microphone.
cushion winds around the side of the electret cap microphone.
ICD-PX440
11
2-9. CHASSIS
2-10. USB ASSY (USB1)
2 two screws
4 chassis
1
Peel off the adhesive sheet.
3
Draw out the USB assy flexible
board from the hole.
board from the hole.
groove
USB assy flexible board
adhesive sheet
86%DVV\IOH[LEOHERDUGVHWWLQJ
2 USB assy (USB1)
hole
1
Draw out the USB assy
from the hole.
from the hole.
Note: When installing the USB assy (USB1), align
the USB assy knob with the case (rear) assy
hole and insert the knob into the hole.
hole and insert the knob into the hole.
ICD-PX440
12
SECTION 3
TEST MODE
1. SETTING THE TEST MODE
Note: Test mode is impossible when battery voltage is not enough.
Do work using the battery with suffi cient battery level.
Setting method :
1. Equip this unit with battery.
2. Slide the [HOLD•POWER ON/OFF] switch in the direction of
1. Equip this unit with battery.
2. Slide the [HOLD•POWER ON/OFF] switch in the direction of
“POWER” until the window display appears.
3. While pressing the [STOP/
x
] and [VOL
−] keys, slide the
[DPC (SPEED CTRL)] switch in the direction of “ON” or
“OFF” (Either “ON” or “OFF” is OK).
“OFF” (Either “ON” or “OFF” is OK).
VOL –
STOP / x
ON OFF DPC (SPEED CTRL)
4. While pressing the [STOP/
x
] and [VOL
−] keys, slide the
[DPC (SPEED CTRL)] switch in the direction opposite to that
specifi ed in step 3.
specifi ed in step 3.
5. While pressing the [STOP/
x
] and [VOL
−] keys, slide the
[DPC (SPEED CTRL)] switch in the direction opposite to that
specifi ed in step 4.
specifi ed in step 4.
6. The test mode menu (“SERVICE MENU”) is displayed, and
enter the test mode. Release the [STOP/
x
] and [VOL
−] keys.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<SERVICE MENU>
ICD-PX440 /E
1.00.00
1.00.00
Destination
Model name
Firmware version
Model name
Firmware version
LCD Display
2. RELEASING THE TEST MODE
Remove battery.
Remove battery.
3. CONFIGURATION OF THE TEST MODE
[
.
] key
[
>
] key
J
j
k
K
Normal mode
Release the [STOP/
x
] and [VOL –] keys
Remove battery.
Initial state of test mode
End of test mode
Determine
using
[
N
]
key
Return using
[STOP/
x
] key
SERVICE MENU
LCD PATTERN
KEY CHECK2
VERSION
KEY CHECK
AUDIO LOOP
SIN
BEEP
LCD CONT
RTC TEST
BATT A/D
ZLOAD
LOW DET
VBUS
FM TEST
KEY COUNT
SLEEP
BATT LIFE
WRITER VER
CHG LOG
LREC LOG
LREC LOG Clear
MENU INIT
SERVICE MENU
While pressing the [STOP/
x
] and [VOL –] keys,
slide the [DPC (SPEED CTRL)] switch
“ON” or “OFF” (Either “ON” or “OFF” is OK).
Slide the [DPC (SPEED CTRL)] switch.
Slide the [DPC (SPEED CTRL)] switch.
ICD-PX440
13
4. OPERATION OF THE TEST MODE
4-1. LCD PATTERN
The lighting check of LCD can be performed.
4-1. LCD PATTERN
The lighting check of LCD can be performed.
Procedure:
1. Enter the test mode.
1. Enter the test mode.
(Refer to “SETTING THE TEST MODE” on page 12)
2. Press
the
[
>
] or [
.
] keys to select the “LCD PATTERN”,
and press the [
N
] key.
3. LCD display pattern is displayed as shown in the following
fi gure.
LCD Display Pattern
LCD Display:
All segments OFF
All segments OFF
Operation indicator LED:
Green lights
Green lights
LCD Display:
All segments ON
All segments ON
Operation indicator LED:
Red lights
Red lights
LCD Display:
Display pattern 1
Display pattern 1
Operation indicator LED:
Orange lights
Orange lights
LCD Display:
Display pattern 2
Display pattern 2
Operation indicator LED:
Orange lights
Orange lights
Key input settings under this mode of operation:
[
>
] or [
.
] : Display pattern change
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-2. KEY CHECK2
Not used for the servicing.
Not used for the servicing.
4-3. VERSION
Model name, initial language, fi rmware version, IPL2 version,
CPU version, eMMC maker code, eMMC capacity, destination,
board ID (board discrimination number) and unique ID can be
confi rmed.
Model name, initial language, fi rmware version, IPL2 version,
CPU version, eMMC maker code, eMMC capacity, destination,
board ID (board discrimination number) and unique ID can be
confi rmed.
Procedure:
1. Enter the test mode.
1. Enter the test mode.
(Refer to “SETTING THE TEST MODE” on page 12)
2. Press
the
[
>
] or [
.
] keys to select the “VERSION”, and
press the [
N
] key.
3. Model name, initial language, fi rmware version, IPL2 version
and CPU version are displayed on page 1/2 of LCD display.
Press the [
>
] or [
.
] keys, eMMC maker code, eMMC
capacity, destination, board ID (board discrimination number)
and unique ID are displayed on page 2/2 of LCD display.
and unique ID are displayed on page 2/2 of LCD display.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
ICD-PX440 /E
MAINFW:1.00.00
IPL2FW:1.00.00
LSI 4252
MAINFW:1.00.00
IPL2FW:1.00.00
LSI 4252
D:11 M:04 L:06
B:YMMDDXXXX#
XXXXXXXXXXXX
B:YMMDDXXXX#
XXXXXXXXXXXX
<VERSION>
<VERSION>
LCD of Display (page 2/2)
LCD of Display (page 1/2)
Board ID (board
discrimination number)
Unique ID
Model name/Destination
Firmware version
IPL2 version
IPL2 version
CPU version
Initial language
eMMC capacity
eMMC maker code
Board ID (board discrimination number):
Y
:
Year
(Hexadecimal)
MM :
Month
DD :
Day
XXXX : The number of the order of production of the above-
mentioned date
#
: Jig number
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
Click on the first or last page to see other ICD-PX440 (serv.man2) service manuals if exist.