SECTION  1
SERVICING  NOTES
NOTE  OF  REPLACING  THE  BOARD
When boards installed by this unit are defective, individual electri-
cal parts that the mount is done cannot be replaced. Replace the 
mounted board, or replace the whole part containing the complete 
mounted board.
ABOUT  THE  DESTINATION  SETTING  WHEN  REPLAC-
ING  THE  MAIN  BOARD
When the MAIN board of this unit is replaced, perform processing 
according to the following procedure.
Precaution
The contents which are not opened to customers are included 
in the following procedure. After you are cautious of handling of 
information, execute work under the suffi cient administration.
1.  About the preparing of tools
Confi rm the method of obtaining the tools to the service headquar-
ters.
2. Setting 
method
Note: The destination setting is impossible when battery voltage is not 
enough.
 
  Do work using the battery with suffi cient battery level.
Procedure:
1.  Equip this unit with battery.
2.  Connect this unit to the PC.
To USB port of PC
IC recorder
Slide the USB slide lever
3.  On PC, unzip the model setting fi le to get folder on PC.
4.  On PC, open the unzipped folder, and select the folder corre-
sponding to the model name and destination of this unit.
01.ICD-PX440_U
02.ICD-PX440_CE7
03.ICD-PX440_LA
04.ICD-PX440_CA
05.ICD-PX440_J
07.ICD-PX440_CN
08.ICD-PX440_KR3
09.ICD-PX440_E
5.  On PC, copy the “DEVINFO.UPG” fi le included in the folder 
selected at step 4 to root folder of this unit.
6.  Remove this unit from the PC.
From USB port of PC
IC recorder
7.  “Updating” is displayed on the screen of this unit, and this unit 
is rebooted automatically.
Updating...
LCD Display
8.  The destination setting is completed.
1. 
SERVICING  NOTES 
 .............................................  
3
2. DISASSEMBLY
2-1. Disassembly 
Flow 
...........................................................   5
2-2. Ornament 
(MIC) 
.............................................................   6
2-3. Case 
(Front) 
Assy 
............................................................   7
2-4.  Loudspeaker (2.8 cm) .....................................................   8
2-5. LCD 
Block 
......................................................................   8
2-6. LCD 
Holder 
....................................................................   9
2-7. MAIN 
Board 
...................................................................   9
2-8.  Electret Cap Microphone (L/R-ch) (MIC1, MIC2) ........   10
2-9. Chassis 
............................................................................  11
2-10. USB Assy (USB1) ..........................................................   11
3. 
TEST  MODE 
 ............................................................   12
4. 
EXPLODED  VIEWS
4-1.  Case Front Section ..........................................................   18
4-2.  MAIN Board Section ......................................................   19
4-3.  Case (Rear) Section ........................................................   20
5. ACCESSORIES 
 .......................................................   21
TABLE  OF  CONTENTS
ICD-PX440
4
3. Confi rmation and initialize method
Procedure:
1.  Equip this unit with battery.
2.  Slide the [HOLD•POWER ON/OFF] switch in the direction of 
“POWER” until the window display appears.
3.  While pressing the [STOP/
x
] and [VOL 
−] keys, slide the 
[DPC (SPEED CTRL)] switch in the direction of “ON” or 
“OFF” (Either “ON” or “OFF” is OK).
VOL –
STOP / x
ON         OFF DPC (SPEED CTRL)
4.  While pressing the [STOP/
x
] and [VOL 
−] keys, slide the 
[DPC (SPEED CTRL)] switch in the direction opposite to that 
specifi ed in step 3.
5.  While pressing the [STOP/
x
] and [VOL 
−] keys, slide the 
[DPC (SPEED CTRL)] switch in the direction opposite to that 
specifi ed in step 4.
6.  The test mode menu (“SERVICE MENU”) is displayed, and 
enter the test mode. Release the [STOP/
x
] and [VOL 
−] keys.
 
(Displayed characters/values in the following fi  gure are ex-
ample)
<SERVICE MENU>
ICD-PX440 /E
1.00.00
Destination
Model name
Firmware version
LCD Display
7.  Press the [
>
] or [
.
] keys to select the “MENU INIT”, and 
press the [
N
] key.
8.  Initialization is performed.
Formatting...
<MENU INIT>
LCD Display
9.  “Success” is displayed, and this unit reboots.
Success
LCD Display
ICD-PX440
5
SECTION  2
DISASSEMBLY
• 
This set can be disassembled in the order shown below.
2-1.  DISASSEMBLY  FLOW
SET
2-2. ORNAMENT 
(MIC)
 (Page 
6)
2-3. CASE 
(FRONT) 
ASSY
 (Page 
7)
2-4 
LOUDSPEAKER (2.8 cm)
 (Page 
8)
2-6. LCD 
HOLDER
 (Page 
9)
2-7. MAIN 
BOARD
 (Page 
9)
2-10. USB ASSY (USB1)
 (Page 
11)
2-8.  ELECTRET CAP MICROPHONE 
 
(L/R-ch) (MIC1, MIC2)
 (Page 
10)
2-9. CHASSIS
 (Page 
11)
2-5. LCD 
BLOCK
 (Page 
8)
‡ JIG
  When disassembling the unit, use the following jig.
 Part No. 
Description
  9-913-402-33  Tool for Disassembling
ICD-PX440
6
Note:
 Follow the disassembly procedure in the numerical order given.
2-2. ORNAMENT 
(MIC)
9
 Insert a jig into the space opened between the case (front) and 
the ornament (MIC) and remove the ornament (MIC) straight in 
the direction of the arrow.
The case (rear) assy should 
be visible through this slit.
Only the mesh (MIC) should 
be visible through this slit.
The microphone electret cap 
should be visible through this slit.
OK
NG
Note 5: When installing the ornament (MIC), confirm that the case (rear) 
assy and mesh (MIC) are visible through the slits.
8 Create an open space between 
the case (front) and the 
ornament (MIC) by pushing the 
case (rear) in the direction of 
the arrow.
six claws
two claws
qa 
ornament 
(MIC)
lid (slot)
speaker wires
USB connector
case (front)
case (rear)
– Rear top view –
– Rear top view –
–Right side –
–Left side –
– Rear bottom view –
2 screw
1 Open the battery case lid.
4 Close the battery case lid.
3 screw
 (1.4)
5 Open the lid (slot).
 Note 
1: Be careful when removing the lid (slot), 
as forcefully pulling to remove it from the 
case (rear) may damage the retainer claw.
6 With the lid (slot) held open, press your fingers 
against the bases of the case (front) and the 
USB connector, and open them slightly.
 Note 
2: 
When opening the case (front), exercise 
great care. If opened with too much force, 
the speaker wires may snap. 
 Note 
3: Using a jig instead of your fingers is also 
acceptable.
case (rear)
Note 4: Check that the two claws on 
the ornament (MIC) have come 
out of the case (rear) block.
Note 6: To see if the claws on the removed 
ornament (MIC) have broken or 
otherwise been damaged, check that 
the claws do not turn white when 
pressure is applied.
Not broken
Not white
claw
claw
two claws
ornament (MIC)
case 
(front)
ornament (MIC)
case 
(front)
Page of 22
Display

Sony ICD-PX440 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony ICD-PX440 (serv.man2) Service Manual ↓ Size: 1.65 MB | Pages: 22 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony ICD-PX440 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony ICD-PX440 (serv.man2) Audio. Information contained in Sony ICD-PX440 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.