DOWNLOAD Sony ICD-P17 Service Manual ↓ Size: 1.21 MB | Pages: 25 in PDF or view online for FREE

Model
ICD-P17
Pages
25
Size
1.21 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
icd-p17.pdf
Date

Sony ICD-P17 Service Manual ▷ View online

5
ICD-P17
Note : This set can be disassemble according to the following sequence.
SECTION 3
DISASSEMBLY
Note : Follow the disassembly procedure in the numerical order given.
3-1. UPPER LID BLOCK ASSY
3-1.
UPPER LID BLOCK ASSY
(Page 5)
3-2.
F-SW BOARD,
P-SW BOARD
(Page 6)
SET
3-3.
MAIN BOARD
(Page 6)
3-4.
PC BOARD
(Page 7)
1
 B 1.7x10
4
 claw
2
 B 1.7x7
8
 screws 1.7x2.5
9
 speaker (SP101)
3
 claws
5
 claws
6
 claw
0
 upper lid block assy
case block assy
7
6
ICD-P17
3-2. F-SW BOARD, P-SW BOARD
3-3. MAIN BOARD
2
 CN703
3
case block assy
4
 F-SW board
5
 P-SW board
3
 Removal the seven solders.
1
 Removal the solder.
3
 screw
4
 claw
5
 claw
case (lower) assy
1
 Removal the two solders.
8
 MAIN board
7
6
 CN801
2
 speaker (SP101)
(1.7x3.0)
7
ICD-P17
3-4. PC BOARD
case (lower) assy
2
 PC board
3
 holder (jack)
1
 screw (1.7x3.7)
8
ICD-P17
SECTION 4
TEST MODE
[Setting Method of the Test Mode]
(1) To  enter the test mode, turn on the  HOLD  switch while
pressing the  STOP  key and  MENU  key at the same time with
the power on.
[Exiting Method of the Test Mode]
Exit the test mode by turning off the power.
[Initial Status of the Test Mode]
When the test mode is set, the LCD display appears as shown
below.
LCD display
P17
/091
[Flow Chart of the Test Mode]
LCD
AUDIO
SLEEP
BEEP
RTC
MENU
COUNT
USB
LED
BATT
KEY
RST
KEY
Initial status of
Test mode.
Set code,LPEC ST,
F/W version display
.
>
.
>
.
>
.
>
.
>
>
.
>
.
.
>
.
>
.
>
.
>
.
>
START
TEST MODE
END
TEST MODE
Turning off the power.
091
t
IC702 version
(Displayed to A or B folder
when version a or b.)
P17
t
Set code
[Operation in the Test Mode]
After entering the test mode, you can move within the test menu by
pressing the  . / >  key. You can move to the submenu by
pressing the  x•B  key. Then each test mode can be executed.
1. LCD test
• LCD is tested all light-on and all light-off.
2. Audio test
Perform the through-playback.
• Contents of the submenu
   DSPLOP: DSP through mode.
• Select the microphone sensitivity with the  MIC SENS  switch.
   H
tLtHtLt……
• MUTE can be set to “ON” or “OFF” with the  ERASE  key.
• The sound volume can be adjusted with the  VOL  volume key
during the audio test except the MUTE mode.
• This test operates in accordance with to the JACK detection test.
It displays the current mode, microphone sensitivity and mute
on the LCD display.
[Example of LCD display]
DSP through mode/MIC: H/MUTE: OFF
tH/OF/DSPLOP
(SET)
 / .
.
.  
/  >
• B
• B
LCD
LCD
ALL
(SELECT)
START
CHK
END
CHK
LCD
OFF
LCD
ON
STOP
STOP
STOP
STOP
OFF LCD
CHK LCD
ALL LCD
AUDIO
DSPLOP
(SET)
.  
/  >
• B
• B
(SELECT)
STOP
STOP
H
OF
DSPLOP
Page of 25
Display

Click on the first or last page to see other ICD-P17 service manuals if exist.