Sony ICD-LX30 Service Manual ▷ View online
ICD-LX30
9
4-2. KEY CHECK
Operation of keys and switches can be checked, and this unit can
return to the factory shipment settings.
Operation of keys and switches can be checked, and this unit can
return to the factory shipment settings.
Note 1: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “KEY CHECK”,
and press the [PLAY/ENTER/
N
] key.
3. Whenever any keys of this unit are pressed or any switches of
this unit are slid, the button count decreases.
<KEY CHECK>
KEY:PREV
REMAIN: 15
KEY:PREV
REMAIN: 15
LCD of Display
*Displayed characters/values are example.
Button count
Confirmed key name
Target keys:
[STOP/
x
], [FF/
M
], [FR/
m
], [PLAY/ENTER/
N
],
[REC/PAUSE/
z
], [NEXT/
>
], [PREV/
.
], [SEARCH],
[ERASE], [VOL +], [VOL –], [MENU]
Target switches:
[HOLD], [POWER]
4. After all the keys and switches are decided, initialization is
performed.
5. “Success” is displayed, and this unit reboots.
Note 2: This unit is not initialized when “Failure” is displayed.
Releasing method:
Remove battery.
Remove battery.
4-3. AUDIO LOOP
Audio loop back operation can be performed.
Audio loop back operation can be performed.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “AUDIO LOOP”,
and press the [PLAY/ENTER/
N
] key.
3. Audio loop back operation is performed.
Note: When mode is active, the recording level for VOR is acquired at
intervals of 1 second, and it is displayed. When the acquired record-
ing level is larger than the VOR setting value, red LED lights up.
ing level is larger than the VOR setting value, red LED lights up.
(Threshold value is based on operation of this unit)
<AUDIO LOOP>
AGC: OFF
Vol: 20 MIC IN
VOR: 00003FFF
AGC: OFF
Vol: 20 MIC IN
VOR: 00003FFF
LCD Display
*Displayed characters/values are example.
Initial value:
Play back volume
: 20 (stereo)
fs
: 44.1 kHz
External microphone : MIC IN
Key input settings under this mode of operation:
[VOL +]
: Volume up
[VOL –]
: Volume down
[PLAY/ENTER/
N
] : External microphone sensitivity
(MIC IN ↔ LINE IN)
[FR/
m
]
: AGC operation (ON ↔ OFF)
Operation of others by the plug/unplug signal (the external micro-
phone jack and headphone jack) are based on operation of this unit.
phone jack and headphone jack) are based on operation of this unit.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
ICD-LX30
10
4-4. SIN
Sine wave can be outputted.
Sine wave can be outputted.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “SIN”, and
press the [PLAY/ENTER/
N
] key.
3. Sine wave is outputted.
<SIN>
Vol:20
Vol:20
LCD Display
*Displayed characters/values are example.
Initial value:
Play back volume : 20 (stereo)
fs
:
44.1kHz
Key input settings under this mode of operation:
[VOL +] : Volume up
[VOL –] : Volume down
Operation of others by the plug/unplug signal (the external micro-
phone jack and headphone jack) are based on operation of this unit.
phone jack and headphone jack) are based on operation of this unit.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-5. BEEP
Beep sound (1.3 kHz) can be outputted.
Beep sound (1.3 kHz) can be outputted.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “BEEP”, and
press the [PLAY/ENTER/
N
] key.
3. Beep sound (1.3 kHz) is outputted.
<BEEP>
1.3KHz ON
1.3KHz ON
LCD Display
*Displayed characters/values are example.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-6. LCD CONT
LCD contrast can be adjusted.
LCD contrast can be adjusted.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “LCD CONT”,
and press the [PLAY/ENTER/
N
] key.
3. Adjustment of LCD contrast becomes available.
<LCD CONT>
Vol: 16
[FF]+ [FR]
Vol: 16
[FF]+ [FR]
[PLAY] Save
LCD Display
*Displayed characters/values are example.
Initial value:
The default setting saved at serial fl ash.
Key input settings under this mode of operation:
[FR/
m
]
: Contrast value decrease
[FF/
M
]
: Contrast value increase
[PLAY/ENTER/
N
] : The current contrast value is written to
serial fl ash.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-7. LCD PATTERN
The check of LCD dead pixel is made.
The check of LCD dead pixel is made.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “LCD PAT-
TERN”, and press the [PLAY/ENTER/
N
] key.
3. LCD display pattern is displayed as shown in the following
fi gure.
LCD Display Pattern
All segments ON
All segments OFF
Partial segments ON
Key input settings under this mode of operation:
[FF/
M
] or [FR/
m
] : Display pattern change
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
ICD-LX30
11
4-8. RTC TEST
The self-test of RTC module can be done.
The self-test of RTC module can be done.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[FF/
M
] or [FR/
m
] keys to select the “RTC TEST”,
and press the [PLAY/ENTER/
N
] key.
3. The self-test of RTC module is executed, and result is dis-
played.
<RTC TEST>
OK
OK
LCD Display
*Displayed characters/values are example.
RTC self-test result
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-9. BATT A/D
A/D value (voltage value and temperature value) acquisition can
be performed.
A/D value (voltage value and temperature value) acquisition can
be performed.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “BATT A/D”,
and press the [PLAY/ENTER/
N
] key.
3. A/D value (voltage value and temperature value) are acquired,
and they are displayed.
(8 bit (The bit shift after LSB side 2 bit omission))
Displayed value are always updated.
<BATT A/D>
AC: 7B
AC: 7B
LCD Display
*Displayed characters/values are example.
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-10. ZLOAD
Not used for the servicing.
Not used for the servicing.
4-11. LOW
DET
Not used for the servicing.
4-12. VBUS
Not used for the servicing.
Not used for the servicing.
4-13. DC-IN
The state of DCIN_XDET can be checked.
The state of DCIN_XDET can be checked.
Procedure:
1. Enter the test mode.
2. Press
1. Enter the test mode.
2. Press
the
[FF/
M
] or [FR/
m
] keys to select the “DC-IN”, and
press the [PLAY/ENTER/
N
] key.
3. The state of DCIN_XDET is displayed.
<DC-IN>
OFF
OFF
LCD Display
*Displayed characters/values are example.
OFF : DCIN_XDET = 1 (H)
ON
: DCIN_XDET = 0 (L)
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-14. KEY
COUNT
The count value of the keys and switches operation can be dis-
played. Distinction of the keys and switches which operated is not
performed
played. Distinction of the keys and switches which operated is not
performed
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “KEY COUNT”,
and press the [PLAY/ENTER/
N
] key.
3. The count value of the keys and switches operation is dis-
played.
<KEY COUNT>
00888
00888
LCD Display
*Displayed characters/values are example.
Count value increase conditions:
One of buttons is pressed.
One of switches is slid.
SD card is inserted.
Headphone or microphone is inserted.
Releasing method:
Remove battery.
Remove battery.
ICD-LX30
12
4-15. SLEEP
It can change into the sleep state for standby current value mea-
surement.
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “SLEEP”,
and press the [PLAY/ENTER/
N
] key.
3. The sleep state selection screen is displayed.
This unit shifts to the sleep state by pressing the [PLAY/
ENTER/
ENTER/
N
] key again.
<SLEEP>
SLEEP:NORMAL
Excuting...
SLEEP:NORMAL
Excuting...
LCD Display
*Displayed characters/values are example.
Releasing method:
Remove battery.
Remove battery.
4-16. BATT
LIFE
Not used for the servicing.
4-17. WRITER
VER
Not used for the servicing.
4-18. CHG
LOG
Not used for the servicing.
4-19. MENU
INIT
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
2. Press the [FF/
1. Enter the test mode.
2. Press the [FF/
M
] or [FR/
m
] keys to select the “MENU
INIT”, and press the [PLAY/ENTER/
N
] key.
3. Initialization of this unit is performed.
“Success” is displayed, and this unit reboots.