ICD-FX8
9
SECTION  3
TEST  MODE
1.  SETTING  THE  TEST  MODE
Note: Test mode is impossible when battery voltage is not enough.
 
  Do work using the battery with suffi cient battery level.
Setting method:
1.  Equip this unit with battery.
2.  Slide the [HOLD•POWER ON/OFF] switch in the direction of 
“POWER ON/OFF” until the window display appears.
3.  Slide the [HOLD•POWER ON/OFF] switch towards the cen-
ter.
4. While pressing the [
x
] and [VOL –] keys, slide the 
[HOLD•POWER ON/OFF] switch in the direction of “HOLD”.
5.  The test mode menu is displayed, and enter the test mode. Re-
lease the [
x
] and [VOL –] keys.
 
(Displayed characters/values in the following fi gure are ex-
ample)
N 1.00.00
02
LCD Display
Memory capacity
Firmware version
Destination
2.  RELEASING  THE  TEST  MODE
Remove battery.
3.  CONFIGURATION  OF  THE  TEST  MODE
[
.
] key
[
>
] key
Main menu
LCD
BEEP
AUDIO
BATAD
RTC
BATT LIFE 
SLEEP
USB
COUNT
VERSION
KEY
INIT
Main menu
J
j
k
K
‡
‡
‡
‡
Normal mode
6OLGHWKH>+2/'‡32:(5212))@VZLWFK
WRZDUGVWKHFHQWHU
:KLOHSUHVVLQJWKH>x@DQG>92/±@NH\V
VOLGHWKH>+2/'‡32:(5212))@VZLWFK
LQWKHGLUHFWLRQRI³+2/'´
5HOHDVHWKH>
x
@DQG>92/±@NH\V
5HPRYHEDWWHU\
,QLWLDOVWDWHRIWHVWPRGH
(QGRIWHVWPRGH
Determine
XVLQJ
[(17(5
N
]
key
5HWXUQXVLQJ
[
x
] key
4.  OPERATION  OF  THE  TEST  MODE
4-1. Main menu
Destination,  fi rmware version and memory capacity can be con-
fi rmed.
Procedure:
1.  Enter the test mode.
2. Destination, fi rmware version and memory capacity are dis-
played on LCD display.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
N 1.00.00
02
LCD Display
Memory capacity
Firmware version
Destination
 
Key input settings under this mode of operation:
 
[VOL +] 
: Volume up
 
[VOL –] 
: Volume down
 [REC/PAUSE/
z
: Microphone sensitivity change
 
[ DISPLAY/ MENU]  : ALC on/off change (default: off)
The settings of volume, microphone sensitivity and DPC on/off 
changed in this mode becomes effective also the modes other than 
“4-2. LCD” and “4-4. AUDIO”.
ICD-FX8
10
4-2. LCD
The lighting check of LCD can be performed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “LCD”, and press 
the [ENTER/
N
] key.
3.  All segments of LCD display are turned on, and operation in-
dicator lights up in orange color.
4.  Press the [
>
] key, All segments of LCD display are turned 
off, and operation indicator lights up in green color.
5.  Press the [
>
] key, the test pattern displayed on LCD display.
6.  Press the [
>
] key, return to state of step 3.
Releasing method:
Press the [
x
] key, return to test mode menu.
4-3. BEEP
Beep sound (1.3 kHz) can be outputted.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “BEEP”, and press 
the [ENTER/
N
] key.
3.  Beep sound (1.3 kHz) is outputted.
 
(Displayed characters/values in the following fi gure are ex-
ample)
BEEP 
13
LCD Display
 
Key input settings under this mode of operation:
 
[VOL +]  : Volume up
 
[VOL –]  : Volume down
Releasing method:
Press the [
x
] key, return to test mode menu.
4-4. AUDIO
Audio loop back operation can be performed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “AUDIO”, and 
press the [ENTER/
N
] key.
3.  Audio loop back operation is performed.
 
(Displayed characters/values in the following fi gure are ex-
ample)
Note: When mode is active, the recording level for VOR is acquired at in-
tervals of 1 second, and it is displayed. When the acquired recording 
level is larger than the VOR setting value, the operation indicator 
LED redly lights up.
 
(Threshold value is based on operation of this unit)
VOR075A
LCF
DPC
LCD Display
 
Key input settings under this mode of operation:
 
[
.
] or [
>
: STHQ/STSP change
 
[ DISPLAY/ MENU] : ALC on/off change (default: off)
 
[
 
A-B] 
: LCF fi lter on/off change (default: on)
Operation of others by the plug/unplug signal (the external micro-
phone jack and headphone jack) are based on operation of this unit.
Releasing method:
Press the [
x
] key, return to test mode menu.
4-5. BATAD
A/D value (voltage value and temperature value) acquisition can 
be performed.
Procedure:
1.  Enter the test mode.
2. Press the [
>
] or [
.
] keys to select the “BATAD”, and 
press the [ENTER/
N
] key.
3.  A/D value (voltage value and temperature value) are acquired, 
and they are displayed by hexadecimal number.
 
(Displayed characters/values in the following fi gure are ex-
ample)
8C
LCD Display
Releasing method:
Press the [
x
] key, return to test mode menu.
ICD-FX8
11
4-6. RTC
The self-test of RTC module can be done.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “RTC”, and press 
the [ENTER/
N
] key.
3.  The self-test of RTC module is executed, and result is dis-
played.
 
(Displayed characters/values in the following fi gure are ex-
ample)
OK
LCD Display
RTC
Releasing method:
Press the [
x
] key, return to test mode menu.
4-7. BATT LIFE
Not used for the servicing.
4-8. SLEEP
It can change into the sleep state for standby current value mea-
surement.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “SLEEP”, and press 
the [ENTER/
N
] key.
3.  The sleep mode selection screen is displayed.
 
(Displayed characters/values in the following fi gure are ex-
ample)
LCD Display
NSLEEP
 
Key input settings under this mode of operation:
 
[
.
] or [
>
]  : Sleep mode change (NORMAL ↔ DEEP)
 
[
N
: This unit shifts to the sleep mode
Releasing method:
Remove battery.
4-9. USB
VBUS detection signal can be checked.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “USB”, and press 
the [ENTER/
N
] key.
3.  The state of VBUS_XDET is displayed.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
LCD Display
VBUSOFF
 OFF 
VBUS_XDET=1 
(H)
 ON 
VBUS_XDET=0 
(L)
 
Key input settings under this mode of operation:
 [ENTER/
N
]  : It shifts to the suspension state.
 
 
  Remove battery, in order to be released from 
 
 
  the suspension state.
Releasing method:
Press the [
x
] key, return to test mode menu.
4-10. COUNT
The count value of the keys and switches operation can be dis-
played. However, distinction of kind of the keys and switches 
which operated is not performed.
Note: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “COUNT”, and 
press the [ENTER/
N
] key.
3.  The count value of the keys and switches operation is dis-
played.
 
(Displayed characters/values in the following fi gure  are  ex-
ample)
0000
LCD Display
 
Count value increase conditions:
 
One of buttons is pushed.
 
One of switches is slid.
 
Headphone or microphone is inserted.
Releasing method:
Remove battery.
ICD-FX8
12
4-11. VERSION
IPL version, Writer version and eMMC driver version can be con-
fi rmed.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “VERSION”, and 
press the [ENTER/
N
] key.
3.  Each versions are displayed as shown in the following fi gure.
 
(Displayed characters/values in the following fi gure are ex-
ample)
1.00.00
IPL
LCD Display
1.00.00
2.55.00
E
IPL version
Writer version
eMMC driver version
 
Key input settings under this mode of operation:
 
[
.
] or [
>
]  : Displayed version change
Releasing method:
Press the [
x
] key, return to test mode menu.
4-12. KEY
Operation of keys and switches can be checked, and this unit can 
return to the factory shipment settings.
Note 1: It cannot move to other modes from this mode.
Procedure:
1.  Enter the test mode.
2.  Press the [
>
] or [
.
] keys to select the “KEY”, and press 
the [ENTER/
N
] key.
3.  Whenever any keys of this unit are pressed or any switches of 
this unit are slid, the button count decreases.
 
(Displayed characters/values in the following fi gure are ex-
ample)
14
FR
LCD Display
Button count
Confirmed key name
 
Target keys:
 
[
x
], [>], [.], [ENTER/
N
], [REC/PAUSE/
z
], 
 
[
 
A-B], [VOL +], [VOL –], [ DISPLAY/ MENU]
 
Target switches:
 
[SCENE] (“MY VOICE” direction, “CLASS” direction), 
 
[HOLD•POWER ON/OFF] (“POWER ON/OFF” direction, 
return from “POWER ON/OFF” direction, “HOLD” direction, 
return from “HOLD” direction)
4.  After all the keys and switches are decided, initialization is 
performed.
5.  “ACCESS” is displayed, and this unit reboots. 
Note 2: This unit is not initialized when operation indicator blinks in red 
color.
Releasing method:
Remove battery.
4-13. INIT
This unit can return to the factory shipment settings.
Procedure:
1.  Enter the test mode.
2. Press 
the 
[
>
] or [
.
] keys to select the “INIT”, and press 
the [ENTER/
N
] key.
3.  Initialization is performed.
 
“ACCESS” is displayed, and this unit reboots.