Subject : 1. Cautions of FLASH MEMORY (IC706) exchange
IC 102
IC 103
IC 107
IC 101
I
IC 108
IC 105
MAIN BOARD
    
(SIDE A)
J101
J102
1
12
13
24
MIC
(PLUG IN POWER)
EAR
OPR
BP100
TP703
IC 507
F-SW BOARD
    
(SIDE A)
A-B REPEAT
/PRIORITY
INDEX/
BOOKMARK
DISPLAY
ERASE
MENU
STOP
TP512
[Precaution when the flash memory (IC706) is replaced]
When the flash memory (IC706) is replaced, be sure to perform the
BAD BLOCK check* and writing of the model code. If they are not
completed, the unit will not operate normally.
* BAD BLOCK check is to check the flash ROM memory
area (the BAD BLOCK area) where data cannot be
guaranteed. The resultant information of this check is
stored in the TOC-AREA so that the BAD BLOCK area
should not be used.
BAD BLOCK Check Procedure
1.
When the power is turned on after the flash memory (IC706) is
replaced, the BAD BLOCK check starts automatically and the
 OPR  (D703) lights in orange.
2.
In about 4 to 5 minutes after start of the check, the  OPR  (D703)
changes the color to green indicating that the check is
completed.
Model Code Writing Procedure
1.
After the BAD BLOCK check is complete, press the  MENU
switch and the  STOP  switch at the same time. While keeping
pressing the  MENU  and the  STOP  switches simultaneously,
turn on the  HOLD  switch to start the test mode.
2.
After the unit enters the test mode, connect TP703 of the MAIN
board and TP512 of the F-SW board with a jumper. Then the
unit enters the Model Code Writing mode.
3.
When the unit is ICD-BP100, press the  >  switch. When
the unit is ICD-BP120, press the  zREC  switch.
4.
When the  OPR  (D703) lights in red, it indicates that the writing
is terminated with success. If the  OPR  (D703) lights in orange,
it indicates that the writing has failed with error. Make another
attempt of writing the model code from the beginning.
5.
Remove the jumper between TP703 of the MAIN board and
TP512 of the F-SW board.
ICD-BP100/BP120
US Model
ICD-BP100/BP120
Canadian Model
AEP Model
UK Model
E Model
ICD-BP100
Tourist Model
ICD-BP100/BP120
SERVICE MANUAL
SUPPLEMENT-1
Ver 1.1  2002. 07
(SPM-02033)
Subject : 1. Cautions of FLASH MEMORY (IC706) exchange
IC 102
IC 103
IC 107
IC 101
I
IC 108
IC 105
MAIN BOARD
    
(SIDE A)
J101
J102
1
12
13
24
MIC
(PLUG IN POWER)
EAR
OPR
BP100
TP703
IC 507
F-SW BOARD
    
(SIDE A)
A-B REPEAT
/PRIORITY
INDEX/
BOOKMARK
DISPLAY
ERASE
MENU
STOP
TP512
[Precaution when the flash memory (IC706) is replaced]
When the flash memory (IC706) is replaced, be sure to perform the
BAD BLOCK check* and writing of the model code. If they are not
completed, the unit will not operate normally.
* BAD BLOCK check is to check the flash ROM memory
area (the BAD BLOCK area) where data cannot be
guaranteed. The resultant information of this check is
stored in the TOC-AREA so that the BAD BLOCK area
should not be used.
BAD BLOCK Check Procedure
1.
When the power is turned on after the flash memory (IC706) is
replaced, the BAD BLOCK check starts automatically and the
 OPR  (D703) lights in orange.
2.
In about 4 to 5 minutes after start of the check, the  OPR  (D703)
changes the color to green indicating that the check is
completed.
Model Code Writing Procedure
1.
After the BAD BLOCK check is complete, press the  MENU
switch and the  STOP  switch at the same time. While keeping
pressing the  MENU  and the  STOP  switches simultaneously,
turn on the  HOLD  switch to start the test mode.
2.
After the unit enters the test mode, connect TP703 of the MAIN
board and TP512 of the F-SW board with a jumper. Then the
unit enters the Model Code Writing mode.
3.
When the unit is ICD-BP100, press the  >  switch. When
the unit is ICD-BP120, press the  zREC  switch.
4.
When the  OPR  (D703) lights in red, it indicates that the writing
is terminated with success. If the  OPR  (D703) lights in orange,
it indicates that the writing has failed with error. Make another
attempt of writing the model code from the beginning.
5.
Remove the jumper between TP703 of the MAIN board and
TP512 of the F-SW board.
ICD-BP100/BP120
US Model
ICD-BP100/BP120
Canadian Model
AEP Model
UK Model
E Model
ICD-BP100
Tourist Model
ICD-BP100/BP120
SERVICE MANUAL
SUPPLEMENT-1
Ver 1.1  2002. 07
(SPM-02033)
Subject : 1. Cautions of FLASH MEMORY (IC706) exchange
IC 102
IC 103
IC 107
IC 101
I
IC 108
IC 105
MAIN BOARD
    
(SIDE A)
J101
J102
1
12
13
24
MIC
(PLUG IN POWER)
EAR
OPR
BP100
TP703
IC 507
F-SW BOARD
    
(SIDE A)
A-B REPEAT
/PRIORITY
INDEX/
BOOKMARK
DISPLAY
ERASE
MENU
STOP
TP512
[Precaution when the flash memory (IC706) is replaced]
When the flash memory (IC706) is replaced, be sure to perform the
BAD BLOCK check* and writing of the model code. If they are not
completed, the unit will not operate normally.
* BAD BLOCK check is to check the flash ROM memory
area (the BAD BLOCK area) where data cannot be
guaranteed. The resultant information of this check is
stored in the TOC-AREA so that the BAD BLOCK area
should not be used.
BAD BLOCK Check Procedure
1.
When the power is turned on after the flash memory (IC706) is
replaced, the BAD BLOCK check starts automatically and the
 OPR  (D703) lights in orange.
2.
In about 4 to 5 minutes after start of the check, the  OPR  (D703)
changes the color to green indicating that the check is
completed.
Model Code Writing Procedure
1.
After the BAD BLOCK check is complete, press the  MENU
switch and the  STOP  switch at the same time. While keeping
pressing the  MENU  and the  STOP  switches simultaneously,
turn on the  HOLD  switch to start the test mode.
2.
After the unit enters the test mode, connect TP703 of the MAIN
board and TP512 of the F-SW board with a jumper. Then the
unit enters the Model Code Writing mode.
3.
When the unit is ICD-BP100, press the  >  switch. When
the unit is ICD-BP120, press the  zREC  switch.
4.
When the  OPR  (D703) lights in red, it indicates that the writing
is terminated with success. If the  OPR  (D703) lights in orange,
it indicates that the writing has failed with error. Make another
attempt of writing the model code from the beginning.
5.
Remove the jumper between TP703 of the MAIN board and
TP512 of the F-SW board.
ICD-BP100/BP120
US Model
ICD-BP100/BP120
Canadian Model
AEP Model
UK Model
E Model
ICD-BP100
Tourist Model
ICD-BP100/BP120
SERVICE MANUAL
SUPPLEMENT-1
Ver 1.1  2002. 07
(SPM-02033)
Subject : 1. Cautions of FLASH MEMORY (IC706) exchange
IC 102
IC 103
IC 107
IC 101
I
IC 108
IC 105
MAIN BOARD
    
(SIDE A)
J101
J102
1
12
13
24
MIC
(PLUG IN POWER)
EAR
OPR
BP100
TP703
IC 507
F-SW BOARD
    
(SIDE A)
A-B REPEAT
/PRIORITY
INDEX/
BOOKMARK
DISPLAY
ERASE
MENU
STOP
TP512
[Precaution when the flash memory (IC706) is replaced]
When the flash memory (IC706) is replaced, be sure to perform the
BAD BLOCK check* and writing of the model code. If they are not
completed, the unit will not operate normally.
* BAD BLOCK check is to check the flash ROM memory
area (the BAD BLOCK area) where data cannot be
guaranteed. The resultant information of this check is
stored in the TOC-AREA so that the BAD BLOCK area
should not be used.
BAD BLOCK Check Procedure
1.
When the power is turned on after the flash memory (IC706) is
replaced, the BAD BLOCK check starts automatically and the
 OPR  (D703) lights in orange.
2.
In about 4 to 5 minutes after start of the check, the  OPR  (D703)
changes the color to green indicating that the check is
completed.
Model Code Writing Procedure
1.
After the BAD BLOCK check is complete, press the  MENU
switch and the  STOP  switch at the same time. While keeping
pressing the  MENU  and the  STOP  switches simultaneously,
turn on the  HOLD  switch to start the test mode.
2.
After the unit enters the test mode, connect TP703 of the MAIN
board and TP512 of the F-SW board with a jumper. Then the
unit enters the Model Code Writing mode.
3.
When the unit is ICD-BP100, press the  >  switch. When
the unit is ICD-BP120, press the  zREC  switch.
4.
When the  OPR  (D703) lights in red, it indicates that the writing
is terminated with success. If the  OPR  (D703) lights in orange,
it indicates that the writing has failed with error. Make another
attempt of writing the model code from the beginning.
5.
Remove the jumper between TP703 of the MAIN board and
TP512 of the F-SW board.
Page of 30