Sony ICD-B10 / ICD-B15 Service Manual ▷ View online

6
ICD-B10/B15
Basic Oper
ations
15
GB
Start playback.
After playing back one message, the unit stops at the beginning of the next
message.
When the last message on a folder has been played back, the unit stops at
the beginning of the last message.
For private listening
Connect an earphone or headphones (not supplied) to the EAR jack. The built-
in speaker will be automatically disconnected. If you plug in headphones, you
will get monaural output from both left and right channels.
To stop playback
To
Do this
stop at the beginning of
Press xSTOP.
the current message
stop at the current position
Press NxPLAY/STOP.
(Playback Pause function)*
To resume playback from that point,
press NxPLAY/STOP again.
* You  can also pause playback by pressing XPAUSE instead of NxPLAY/
STOP. The OPR indicator will flash in green.  After an hour, the unit goes
into the stop mode at the current position.
Playing back all messages in a folder continuously
— Continuous Play
See page 36.
3
OPR indicator
(lights in green
during playback.)
EAR jack
Counter
display (or
the selected
display
mode)
2
Turn VOL to adjust
the volume.
1
Press NxPLAY/STOP.
Continued
16
GB
Playing Back Messages (continued)
Other operations
To
Do this
go back to the beginning
Press . once.***
of the current message**
skip to the next  message**
Press 
> once.***
go back to previous
Press . or > repeatedly.***
messages/skip to
(During stop mode, keep the button
succeeding messages
pressed to skip the messages
continuously.)
play back rapidly or
Set PLAY  SPEED to FAST or SLOW.
slowly
The messages will be played back
about 30% faster or 15% slower than
normal.
play messages with
Set PLAY SPEED to NORMAL.
normal speed
** If you have set a bookmark on the message, the unit stops at the bookmark.
*** These operations are for when EASY-S  is set to OFF.  For operations when
EASY-S  is set to ON, see page 17.
Various Ways of Playback
Playing back a message repeatedly — Repeat Play
During playback, press  NxPLAY/STOP for more than one second.
“ will be displayed and the selected message will be played back
repeatedly.
To resume normal playback, press NxPLAY/STOP again. To stop
playback, press xSTOP.
Playing the beginning of each message — Scanning Play
During stop mode, press NxPLAY/STOP  for more than one second.
“SCAN” will be displayed in the display window and the first 5 seconds of
each message in the selected folder will be played back.
When you find the desired message, press NxPLAY/STOP. The message
will be played back until the end.
Basic Oper
ations
17
GB
Searching forward/backward during playback (Cue/Review)
To search forward, keep > pressed during playback and release the
button at the point you wish to resume playback.
To search backward, keep . pressed during playback and release the
button at the point you wish to resume playback.
The unit searches at slow speed (unit of 4 seconds) with playback sound. It
is useful when checking one word forward or behind.
If you keep > or .pressed, the unit starts searching at higher speed.
Between messages the unit pauses for 2 seconds.
During cue/review,  the counter will be displayed, regardless of the
display mode setting (page 34).
You  can cue or review during playback pause. The unit goes back into
playback pause at the point you release > or ..
Tip
When fast playback is done to the end of the last message,  
“ END ”  flashes
for 5 seconds and the OPR indicator lights up in green. (You  cannot hear
the playback sound.) If you keep  . pressed while “ END ”  is flashing,
the messages are played back rapidly,   and normal playback will start at
the point you release the button.
When “ END ”  stops flashing and the OPR indicator goes off, the unit will
stop at the beginning of the last message.
If the last message is long and  you wish to start playback at a later part of
the message, keep > pressed to play back the message to the end and
then press . while  “ END ”  is flashing to go back to the desired point .
(For messages other than the last one,  go to the beginning of the next
message and play backward to the desired point.)
Locating quickly the point you wish to start playback (Easy
Search)
When EASY-S  is set to ON (page 36), you can quickly locate the point you
wish to start playback by pressing  > or . repeatedly during playback
or playback pause.
You  can go back approx. 3 seconds by pressing 
. once, or advance
approx 10 seconds by pressing > once.  This function is useful when
locating a desired point in a long recording.
18
GB
Playing Back the Specified Section
Repeatedly  — A-B Repeat
While playing back a message, you can set the start (A) and end (B) points
for a section you wish to play repeatedly.
1
During playback, press A-B REPEAT  briefly.
The starting point (A) of the section you wish to play
repeatedly is set.  “ A-B B”  flashes.
2
During playback, press A-B REPEAT  briefly.
The finishing point (B) of the section is set.
“ A-B”  is displayed and the specified section is played
back repeatedly.
To resume normal playback
Press NxPLAY/STOP.
To stop A-B Repeat playback
Press xSTOP.
Notes
• You  cannot set A-B Repeat for a section that overlaps two or more messages.
• If you do not set the finishing point (B), the finishing point is automatically set
at the end (or the beginning) of the message.
A-B REPEAT
7
ICD-B10/B15
Basic Oper
ations
19
GB
Erasing Messages
You  can erase the recorded messages one by one or all messages in a folder
at a time.
Note that once a recording has been erased, you cannot retrieve it.
Erasing messages one by one
When a message is erased, the remaining messages will advance and
renumbered so that there will be no space between messages.
To cancel erasing
Press xSTOP before step 2.
1
 Press ERASE while playing back
the message you want to erase
or press ERASE for more than 1
second during stop mode.
A beep will sound and the message
number and “ ERASE”  will flash
while the first and last 5 seconds of
the message are played back 10
times.
2
 Press ERASE while the message is
being played back.
The message is erased and the
remaining messages will be
renumbered. (For example, if you
erase Message 3, Message 4 will be
renumbered as Message 3. When
erasing is completed, the unit will
stop at the beginning of the
following message.)
Erase Message 3
Message 1 Message 2 Message 3 Message 4
Before erasing
After erasing
Remaining messages are renumbered.
Message 1
Message 4 Message 5
Message 2 Message 3
Continued
20
GB
Erasing all messages in a folder
2
While pressing  xSTOP,
press ERASE for more
than 1 second.
“ ALL ERASE”  will flash
for 10 seconds.
To cancel erasing
Press xSTOP before step 3.
Erasing Messages (continued)
To erase other messages
Repeat steps 1 and 2.
To erase a message partially
First divide the message by adding an index (see page 23) and then follow
the steps on page 19 to erase the message.
e.g.
Folder A
Folder B
Message 1 Message 2 Message 3
Blank space
Blank space
Message 1 Message 2
Message 3
Message 1 Message 2
Message 3
3
While the display is
flashing, press ERASE.
1
Press FOLDER to
select the folder you
want to erase.
8
ICD-B10/B15
2-2. F-SW BOARD
Note : This set can be disassemble according to the following sequence.
SECTION 2
DISASSEMBLY
Note : Follow the disassembly procedure in the numerical order given.
2-1. SUB BLOCK ASSY, UPPER LID
Set
Sub Block Assy, Upper Lid
F-SW Board
Main Board
1
screw (B1.7x10)
6
sub block assy, upper lid
case assy
4
claw
3
claws
5
2
screw (B1.7x7)
7
screws (B1.7x2.5)
8
speaker
1
CN703
case assy
3
F-SW board
2
9
ICD-B10/B15
2-3. MAIN BOARD
3
screw (B1.7x10)
2
speaker
1
Removal the solders
6
MAIN board
4
claw
5
claw
case assy
Page of 30
Display

Click on the first or last page to see other ICD-B10 / ICD-B15 service manuals if exist.