Sony HT-CT150 / HT-CT350 / SA-WCT150 / SA-WCT350 Service Manual ▷ View online
SA-WCT150/WCT350
9
2-4. AMP BLOCK
Note: Please set as shown in fi gure and work.
1 four screws
(BVTT4
u 20)
2 cover (fan)
3 four screws
(BVTP3
u 8)
4 four screws
(BVTP4
u 20)
5 cover (connector)
6 cushion (H15)
7 wire (flat type) (13 core)
(CN832)
8 six screws
(BVTP3
u 8)
8 two screws
(BVTP3
u 8)
qa
9 holder (AMP)
q; connector (CN151)
qs AMP block
bottom side
SA-WCT150/WCT350
10
2-5. CASE (TOP) BLOCK, BACK PANEL BLOCK
Note 1: This illustration sees the AMP block from back panel side.
1 two screws
(BVTP3
u 8)
1 seven screws
(BVTP3
u 8)
2
3 wire (flat type) (15 core)
(CN831)
4 case (top) block
5 Lift up the two lead pins.
6 connector
(CN560)
7 connector
(CN1009)
8 wire (flat type) (19 core)
(CN1020)
9 wire (flat type) (17 core) (CN1019) (WCT150)
wire (flat type) (23 core) (CN1018) (WCT350: US, CND, SP, TW, TH)
wire (flat type) (25 core) (CN1017) (WCT350: AEP, RU, UK)
q; six screws
(BVTP3
u 8)
qa back panel block
Note 2: There is no tuner (TU601)
in SA-WCT150.
2-6. MAIN BOARD
Note: This illustration sees the AMP block from MAIN board side.
1 three screws
(BVTP3
u 16)
2 heatsink (AMP)
3 Lift up the lead pin.
4 connector (CN562)
5 connector (CN1016)
6 connector (CN564)
7 seven screws
(BVTP3
u 8)
8 MAIN board
Ver. 1.3
• Abbreviation
CND : Canadian model
RU
CND : Canadian model
RU
: Russian model
SP
: Singapore model
TH
: Thai model
TW
: Taiwan model
SA-WCT150/WCT350
11
SECTION 3
TEST MODE
1. TEST MODES OTHER THAN THE TEST MENU
These are executable test mode even if not entering the test menu.
These are executable test mode even if not entering the test menu.
Note: Do not use the remote commander. Execute the operation with the
key of set.
1-1. Cold Reset
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the three buttons [INPUT SELECTOR], [VOLUME –]
and [
?/1
] simultaneously.
3. The message “COLD RESET” appears on the fl uorescent indi-
cator tube, then turn the power off.
1-2. AM Step Change (SA-WCT350: US, Canadian, Sin-
gapore, Taiwan and Thai models)
Procedure:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press the [INPUT SELECTOR] button to select the “TUNER
AM”.
3. Press the [
?/1
] button to turn the power off.
4. While pressing the [INPUT SELECTOR] button, press the
[
?/1
] button.
5. It turns power on and display “AM 9k Step” or “AM 10k
Step”, and thus the tuning interval is changed over.
2. TEST MODES IN THE TEST MENU
These are the test modes done in the test menu.
These are the test modes done in the test menu.
Note: Do not use the remote commander. Execute the operation with the
key of set.
Setting method of the test menu:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press and hold down the two buttons [VOLUME +] and [IN-
PUT SELECTOR] simultaneously (around 5 seconds).
3. The message “TEST MENU” appears on the fl uorescent indi-
cator tube and enter the test menu.
2-1. Panel test Mode
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“PANEL”, and press the [INPUT SELECTOR] button.
3. All segments in the fl uorescent indicator tube are lighted up.
And half segments in the fl uorescent indicator tube are lighted
up, others half segments in the fl uorescent indicator tube are
lighted up, then all segments in the fl uorescent indicator tube
are lighted up. These operation is repeated.
up, others half segments in the fl uorescent indicator tube are
lighted up, then all segments in the fl uorescent indicator tube
are lighted up. These operation is repeated.
4. When all segments in the fl uorescent indicator tube are lighted
up in the state of step 3, press the [VOLUME +] button and
model information is displayed on the fl uorescent indicator
tube.
model information is displayed on the fl uorescent indicator
tube.
Each time the [VOLUME +] button is pressed, the display
changes from destination information, MC version, SYS ver-
sion, UI version, ST version, TA version, DSP version, TM
version, CLA version, CEC version in this order, and returns
to the model information display.
changes from destination information, MC version, SYS ver-
sion, UI version, ST version, TA version, DSP version, TM
version, CLA version, CEC version in this order, and returns
to the model information display.
5. When [INPUT SELECTOR] button is pressed while the each
version is displayed, year, month and day of the software cre-
ation is displayed.
ation is displayed.
When [INPUT SELECTOR] button is pressed again, the dis-
play returns to the each version display.
play returns to the each version display.
6. In the state of step 3, press the [VOLUME –] button and “K 0”
is displayed on the fl uorescent indicator tube.
“K 0” value increases whenever a button on the set is pressed.
However, once a button has been pressed, it is no longer taken
into account.
However, once a button has been pressed, it is no longer taken
into account.
All buttons on the set is pressed, “OK” and “K 4” are alter-
nately displayed on the fl uorescent indicator tube.
nately displayed on the fl uorescent indicator tube.
7. To release from this mode, press the [
?/1
] button.
2-2. Model Name Display
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“CTXXX” (XXX: 150 or 350).
2-3. MC Version Display
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“MC X.XXX” (X.XXX: MC
μ-com version).
2-4. HDMI Version Display
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“HDMI X.XX” (X.XX: HDMI
μ-com version).
2-5. AMP Test Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-6. Tuner Factory Preset Change
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-7. Tone Test Check
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“TONE TEST”, and press the [INPUT SELECTOR] button.
3. The output speaker is displayed on the fl uorescent indicator
tube. At this time, the audio output check from each speaker is
possible.
possible.
4. To release from this mode, press the [
?/1
] button.
2-8. VACS Level Display On/off Change
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-9. VACS On/off Change
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-10. DSP Halt Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-11. DSP Status Display Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-12. DSP RAM Read/write Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-13. HDMI Halt Mode
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“HDMI HALT”, and press the [INPUT SELECTOR] button.
3. The message “HALT ON” appears on the fl uorescent indicator
tube, then HDMI
μ-com communication is halt.
4. To release from this mode, execute “1-1. Cold Reset”.
Ver. 1.2
SA-WCT150/WCT350
12
2-14. HDMI
μ-com Update Mode
Note: Only when it is necessary to update HDMI
μ-com (IC3000 on the
HDMI board) from DMPORT jack, this menu is used.
Procedure:
1. Enter the test menu.
2. The jig for the update is connected. Confi rm the jig to service
1. Enter the test menu.
2. The jig for the update is connected. Confi rm the jig to service
headquarters.
3. Press the [VOLUME +]/[VOLUME –] buttons to select the
“HDMI UPD”, and press the [INPUT SELECTOR] button.
4. When the update is completed, “1-1. Cold Reset” is executed.
5. Please execute “2-4. HDMI Version Display”, and confi rm the
5. Please execute “2-4. HDMI Version Display”, and confi rm the
HDMI version.
2-15. Digital Media Port Test Mode
Not used for the servicing.
Press the [
Not used for the servicing.
Press the [
?/1
] button if having entered this mode.
2-16. Digital Media Port Device Test Mode
Note: Execute this mode after connecting the digital media port device
with this set.
Procedure:
1. Press the [INPUT SELECTOR] button to select the
1. Press the [INPUT SELECTOR] button to select the
“DMPORT”.
2. Enter the test menu.
3. Press the [VOLUME +]/[VOLUME –] buttons to select the
3. Press the [VOLUME +]/[VOLUME –] buttons to select the
“DMPORT DEV”, and press the [INPUT SELECTOR] button.
4. The digital media port adaptor enter to the test mode. The op-
eration of the test mode is different according to each adaptor.
5. To release from this mode, press the [
?/1
] button.
2-17. UART Flash (TARGET) Mode
Note: Only when it is necessary to update system
μ-com (IC1002 on the
MAIN board) from DMPORT jack, this menu is used.
Procedure:
1. Press the [INPUT SELECTOR] button to select the
1. Press the [INPUT SELECTOR] button to select the
“DMPORT”.
2. Enter the test menu.
3. Press the [VOLUME +]/[VOLUME –] buttons to select the
3. Press the [VOLUME +]/[VOLUME –] buttons to select the
“DMP TARGET”, and press the [INPUT SELECTOR] button.
4. The message “TARGET” appears on the fl uorescent indicator
tube.
5. The jig for the update is connected. Confi rm the jig to service
headquarters.
6. When the update is completed, pull out the AC cord.
7. Please execute “2-3. MC Version Display”, and confi rm the
7. Please execute “2-3. MC Version Display”, and confi rm the
MC version.
2-18. Cold Reset
Note: Execute this mode before returning the customer this set.
Procedure:
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
1. Enter the test menu.
2. Press the [VOLUME +]/[VOLUME –] buttons to select the
“COLD RESET”, and press the [INPUT SELECTOR] button.
3. The message “COLD RESET.” appears on the fl uorescent in-
dicator tube, then turn the power off.
Click on the first or last page to see other HT-CT150 / HT-CT350 / SA-WCT150 / SA-WCT350 service manuals if exist.