17
HCD-XGV80
FWD the tape A
“TAPE A AG-2”
Fast forward the tape A
“TAPE A AG-3”
RVS the tape A
“TAPE A AG-4”
Rewind the tape A
“TAPE A AG-5”
FWD the tape B
“TAPE B AG-2”
Rewind the tape A
“TAPE A AG-1”
Fast forward the tape B
“TAPE B AG-3”
RVS the tape B
“TAPE B AG-4”
Rewind the tape B
“TAPE B AG-5”
Shut off
2 minutes
Shut off or 20 seconds
2 minutes
Shut off
2 minutes
Shut off or 20 seconds
2 minutes
Shut off
Aging mode sequence (Tape deck section):
2. Tape Deck Section
• The sequence during the aging mode is following as below.
• If an error occurred, stop display that step.
• The sequence during the aging mode is following as below.
• If an error occurred, stop display that step.
Note: “TAPE * AG- * ” is display of each step.
3. CD Section
• The sequence during the aging mode is following as below.
• If an error occurred, stop display that step.
• The sequence during the aging mode is following as below.
• If an error occurred, stop display that step.
Aging mode sequence (CD section):
DISC 1
chucking
TOC Read
Track 1 Play
Tray Tun
Tray Turn
DISC 4
Chucking
2 seconds
Last Track Play
TOC Read
Track 1 Play
Last Track play
[VACS ON/OFF]
• The volume control by VACS is turned ON/OFF.
Procedure:
1. Press the \/1 button to turn the power ON.
2. Press the PLAY MODE and \/1 buttons simultaneously.
3. The reaction display appears when switcing ON/OFF.
• The volume control by VACS is turned ON/OFF.
Procedure:
1. Press the \/1 button to turn the power ON.
2. Press the PLAY MODE and \/1 buttons simultaneously.
3. The reaction display appears when switcing ON/OFF.
2 seconds
2 seconds
18
HCD-XGV80
Torque Measurement
Mode
Torque Meter
Meter Reading
2.9~6.9 mN•m
FWD
(30 to 70 g•cm)
(0.42 – 0.97 oz•inch)
FWD
CQ-102C
0.19~0.59 mN•m
back tension
(2 to 6 g•cm)
(0.03 – 0.08 oz•inch)
7.8~16.7 mN•m
FF/REW
CQ-201B
(80 to 170 g•cm)
(1.11 – 2.36 oz • inch)
SECTION 5
MECHANICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
SECTION 6
ELECTRICAL ADJUSTMENTS
DECK SECTION 0 dB = 0.775 V
Precaution
1. Demagnetize the record/playback head with a head demagne-
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual. (As a general rule, playback circuit
adjustment should be completed before performing recording
circuit adjustment.)
adjustment should be completed before performing recording
circuit adjustment.)
6. The adjustments should be performed for both L-CH and R-CH.
7. Switches and controls should be set as follows unless other-
7. Switches and controls should be set as follows unless other-
wise specified.
8. Set to the test mode.
(1) Press the \/1 button to turn the power ON.
(2) Select the function “TAPE A or B”.
(3) Press the button of x (TC-B) , ENTER ,and DISC 3
(2) Select the function “TAPE A or B”.
(3) Press the button of x (TC-B) , ENTER ,and DISC 3
simultaneously, to set the tape deck test mode
and displays “TEST MODE” on the fluorescent indicator
tube.
and displays “TEST MODE” on the fluorescent indicator
tube.
(4) To release from the test mode, press the \/1 button.
• Test Tape
Tape
Signal
Used for
P-4-A100
10 kHz, – 10 dB
Azimuth Adjustment
WS-48B
3kHz, 0dB
Tape Speed Adjustment
19
HCD-XGV80
Record/Playback Head Azimuth Adjustment
DECK A
DECK A
DECK B
Note: Perform this adjustments for both decks
Procedure:
1. Mode: Playback (FWD)
Procedure:
1. Mode: Playback (FWD)
set
MAIN board
MD (VIDEO) OUT jack (J701)
L-CH, R-CH
MD (VIDEO) OUT jack (J701)
L-CH, R-CH
+
level meter
test tape
P-4-A100
(10 kHz, – 10 dB)
P-4-A100
(10 kHz, – 10 dB)
Screw
position
position
L-CH
peak
peak
within
1dB
1dB
Output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
1dB
1dB
Screw
position
position
R-CH
peak
peak
3. Mode: Playback
set
test tape
P-4-A100
(10 kHz, – 10 dB)
P-4-A100
(10 kHz, – 10 dB)
R-CH
oscilloscope
L-CH
R-CH
V
H
waveform of oscilloscope
in phase 45
°
90
°
135
°
180
°
good
wrong
MAIN board
MD (VIDEO) OUT jack (J701)
L-CH
MD (VIDEO) OUT jack (J701)
L-CH
4. Repeat step 1 to 3 in playback (REV) mode.
5. After the adjustments, apply suitable locking compound to the
5. After the adjustments, apply suitable locking compound to the
pats adjusted.
Adjustment Location: Playback Head (Deck A).
Record/Playback/Erase Head (Deck B).
forward
reverse
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
so that outputs match within 1dB of peak.
Tape Speed Adjustment
DECK B
Procedure:
Mode: Playback
DECK B
Procedure:
Mode: Playback
set
MAIN board
MD (VIDEO) OUT jack (J701)
L-CH, R-CH
MD (VIDEO) OUT jack (J701)
L-CH, R-CH
+
–
–
frequency counter
test tape
P-4-A100
(10 kHz, – 10 dB)
P-4-A100
(10 kHz, – 10 dB)
1. Insert the WS-48B into the deck B.
2. Press the H button on the deck B.
3. Adjust the tape speed adjustment control inside motor so that
2. Press the H button on the deck B.
3. Adjust the tape speed adjustment control inside motor so that
frequency counter reads 3,000
± 90Hz.
Sample value of wow and flutter W.RMS (JIS) less than 0.3%
WS-48B
WS-48B
Adjustment Location:
Tape speed Adjustment
Tape speed adjustment
control inside motor
control inside motor
20
HCD-XGV80
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
3. Use an oscilloscope with more than 10M
Ω impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
following checks.
S-Curve Check
BD board
Oscilloscope
TP(FE)
TP(DVC)
TP(DVC)
Procedure :
1. Connect oscilloscope to TP (FE).
2. Connect between TP (FE) and TP (DVC ( 1.65 V)) by lead
1. Connect oscilloscope to TP (FE).
2. Connect between TP (FE) and TP (DVC ( 1.65 V)) by lead
wire.
3. Press the \/1 button to turn the power ON.
4. Load a disc (LUV-P01) and actuate the focus search. (In conse-
4. Load a disc (LUV-P01) and actuate the focus search. (In conse-
quence of open and close the disc tray, actuate the focus search)
5. Confirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B. And confirm peak to peak level within 2
±0.5 Vp-p.
±0.5 Vp-p.
symmetry
S-curve waveform
within 2
±
0.5Vp-p
A
B
6. After check, remove the lead wire connected in step 2.
Note : • Try to measure several times to make sure than the ratio
Note : • Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to TP (RFDC) and TP (RFAC).
2. Press the \/1 button to turn the power ON.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check RF
1. Connect oscilloscope to TP (RFDC) and TP (RFAC).
2. Press the \/1 button to turn the power ON.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: Clear RF signal waveform means that the shape “◊” can be
clearly distinguished at the center of the waveform.
VOLT/DIV : 200mV
TIME/DIV : 500ns
TIME/DIV : 500ns
level : 1.45
±
0.3Vp-p
E-F Balance (1 Track jump) Check
TP(TE)
TP(DVC)
TP(DVC)
BD board
oscilloscope
Procedure:
1. Connect oscilloscope to TP (TE) and TP (DVC) board.
2. Press the \/1 button to turn the power ON.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the bB button. (Becomes the 1track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscillo-
1. Connect oscilloscope to TP (TE) and TP (DVC) board.
2. Press the \/1 button to turn the power ON.
3. Load a disc (LUV-P01) and playback the number nine track.
4. Press the bB button. (Becomes the 1track jump mode.)
5. Confirm that the level B and A (DC voltage) on the oscillo-
scope waveform.
B=1.3
±
0.6Vp-p
symmetry
A (DC voltage)
center of
waveform
waveform
B
0V
Specified level:
× 100=less than – 22%
B
A
Checking Location:
[BD BOARD] (SIDE B)
DVC
RFDC
RFAC
TE
FE
SE
DVC
TP(RFDC)
TP(RFAC)
TP(RFAC)
BD board
oscilloscope
Click on the first or last page to see other HCD-XGV80 / LBT-XGV80 service manuals if exist.