DOWNLOAD Sony HCD-XG100AV / HCD-XG900AV Service Manual ↓ Size: 9.16 MB | Pages: 85 in PDF or view online for FREE

Model
HCD-XG100AV HCD-XG900AV
Pages
85
Size
9.16 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hcd-xg100av-hcd-xg900av.pdf
Date

Sony HCD-XG100AV / HCD-XG900AV Service Manual ▷ View online

11
HCD-XG100AV/XG900AV
3-8.
BASE  UNIT (BU-5BD32L)
3
base unit
(BU-5BD32L)
1
BU fitting screw
2
boss
3-9.
DISC  TABLE
Note: When the disc table is installed, adjust the positions of  roller cam
and mark 
B
 as shown in the figure, then set to the groove of disc
table.
1
two screws
(BVTP3 
×
 8)
A
2
two brackets (BU)
3
step screw
4
disc table
A
12
HCD-XG100AV/XG900AV
[CD Delivery Mode]
• This mode moves the optical pick-up to the position durable to
vibration. Use this mode when returning the set to the customer
after repair.
Procedure:
1. Press the
?
/
1
button to turn the power ON.
2. Press the 
[LOOP]
 and
?
/
1
buttons simultaneously.
3. A message “LOCK” is displayed on the fluorescent indicator
tube, and the CD delivery mode is set.
[LED and Fluorescent Indicator Tube All Lit, Key Check
Mode]
Procedure:
1. Press three buttons of 
[    /CLOCK SET]
[ENTER/NEXT]
,
and 
[DISC 2]
 simultaneously.
2. LEDs and fluorescent indicator tube are all turned on.
Press the 
[DISC 2]
 button, and the key check mode is acti-
vated.
3. In the key check mode, the fluorescent indicator tube displays
“K 0 J0 V0”. Each time a button is pressed, “K” value in-
creases. However, once a button is pressed, it is no longer taken
into account.
“J” value increases like 1, 2, 3 ... if turn the JOG dial clock-
wise, or it decreases like 0, 9, 8 ... if turn the JOG dial counter-
clockwise.
“V” value increases like 1, 2, 3 ... if turn the 
[VOLUME]
 dial
clockwise, or it decreases like 0, 9, 8 ... if turn the JOG dial
counterclockwise.
4. To release from this mode, press three buttons in the same
manner as step 1, or disconnect the power cord.
c
[MC Cold Reset]
• The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Turn the power ON or set to the DEMO mode.
2. Press three buttons of 
[    /CLOCK SET]
[ENTER/NEXT]
, and
?
/
1
simultaneously.
3. The set is reset, and displays “COLD RESET”, then becomes
DEMO mode.
[MC Hot Reset]
• This mode resets the set with the preset data kept stored in the
memory. The hot reset mode functions same as if the power
cord is plugged in and out.
Procedure:
1. Turn the power ON or set to the DEMO mode.
2. Press three buttons of 
[    /CLOCK SET]
[ENTER/NEXT]
,
and 
[DISC 1]
 simultaneously.
3. The set is reset, and becomes standby state.
[Change-over the AM Tuning Interval]
(EXCEPT AEP, UK, and Saudi Arabia models)
• The AM tuning interval can be changed over 9 kHz or 10 kHz.
Procedure:
1. Press the
?
/
1
button to turn the power ON.
2. Select the function “TUNER”, and press the 
[TUNER/BAND]
button to select the BAND “AM”.
3. Press the
?
/
1
button to turn the power OFF.
4. Press the 
[ENTER/NEXT]
 and
?
/
1
buttons simultaneously,
and the display on the fluorescent indicator tube changes to
“AM 9 K STEP” or “AM 10 K STEP”, and thus the tuning
interval is changed over.
c
SECTION  4
TEST  MODE
c
13
HCD-XG100AV/XG900AV
[Aging Mode]
This mode can be used for operation check of tape deck section.
Tape deck section work in parallel.
• If an error occurred:
The aging operation stops and display then status.
• If no error occurs:
The aging operation continues repeatedly.
Procedure:
1. Load the tapes into the decks A and B respectively.
2. Press the 
[FUNCTION]
 button to select the function “CD”.
3. Press the 
[PLAY MODE]
 button to set the “ALL DISCS” mode,
and press the 
[REPEAT]
 button to “REPEAT” off.
4. Press three buttons of 
[    /CLOCK SET]
[ENTER/NEXT]
,
and 
[DISC 4]
 simultaneously.
5. The aging mode is activated, if the indicator of disc tray num-
ber on the fluorescent indicator tube is blinking.
6. To release from the aging mode, press the
?
/
1
button to turn
the power OFF and operate the cold reset. (Refer to the “MC
Cold Reset”)
1. Display at the Aging Mode
• Display operating state of tape deck section alternately.
• If an error occurred, stop display.
2. Tape Deck Section
• The sequence during the aging mode is following as below.
• If an error occurred, stop display that step.
Aging mode sequence (Tape deck section) :
Rewind the tape A and B
“TAPE A AG-1”
Shut off
FWD play the tape A
“TAPE A AG-2”
2 minutes
Fast forward the tape A
“TAPE A AG-3”
Shut off or 20 seconds
REV play the tape A
“TAPE A AG-4”
2 minutes
Rewind the tape A
“TAPE A AG-5”
Shut off
FWD play the tape B
“TAPE B AG-2”
2 minutes
Fast forward the tape B
“TAPE B AG-3”
Shut off or 20 seconds
REV play the tape B
“TAPE B AG-4”
2 minutes
Rewind the tape B
“TAPE B AG-5”
Shut off
Note:
 “TAPE 
*
 AG-
*
” is display of each step.
c
14
HCD-XG100AV/XG900AV
SECTION  5
MECHANICAL  ADJUSTMENTS
SECTION  6
ELECTRICAL  ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads pinch rollers
erase head
rubber belts
capstan
idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
Mode
Torque Meter
Meter Reading
3.1 to 6.96 mN•m
FWD
CQ-102C
(31 to 71 g•cm)
(0.43 – 0.98 oz•inch)
FWD
0.20 to 0.58 mN•m
back tension
CQ-102C
(2 to 6 g•cm)
(0.03 – 0.08 oz•inch)
3.1 to 6.96 mN•m
REV
CQ-102RC
(31 to 71 g•cm)
(0.43 – 0.98 oz • inch)
REV
0.20 to 0.58 mN•m
back tension
CQ-102RC
(2 to 6 g•cm)
(0.03 – 0.08 oz • inch)
6.97 to 14.02 mN•m
FF/REW
CQ-201B
(71 to 143 g•cm)
(0.99 – 1.99 oz • inch)
9.80 mN•m
FWD tension
CQ-403A
(100 g or more)
(3.53 oz or more)
9.80 mN•m
REV tension
CQ-403A
(100 g or more)
(3.53 oz or more)
Precaution
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in
this service manual.  (As a general rule, playback circuit ad-
justment should be completed before performing recording
circuit adjustment.)
6. The adjustments should be performed for both L-CH and R-
CH.
7. Switches and controls should be set as follows unless other-
wise specified.
8. Set to  the DOLBY NR OFF.
9. Set to the test mode.
(1) Press the
?
/
1
button to turn the power ON.
(2) Select the function “TAPE A or B”.
(3) Press the button of 
[    /CLOCK SET]
[ENTER/NEXT]
,
and 
[DISC 3]
 simultaneously, to set the tape deck test mode
and displays “TEST MODE”  on the fluorescent indicator
tube.
(4) To release from the test mode, press the
?
/
1
button.
• Test Tape
Tape
Signal
Used for
P-4-A100
10 kHz, – 10 dB
Azimuth Adjustment
WS-48B
3 kHz, 0 dB
Tape Speed Adjustment
P-4-L300
315 Hz, 0 dB
Playback Level Adjustment
0 dB = 0.775 V
DECK  SECTION
c
Page of 85
Display

Click on the first or last page to see other HCD-XG100AV / HCD-XG900AV service manuals if exist.